Audit log (22 events)

# Level Stage Message Time
271 info asana_fetched Resolving Asana task reference 'https://app.asana.com/1/1203754389657527/project/1211039529104749/task/1211709017140700' 2026-04-30T10:30:48
272 info asana_fetched Loaded Asana task: Teresa Ramirez
payload
{
  "customer": "Teresa Ramirez",
  "gid": "1211709017140700",
  "title": "Teresa Ramirez"
}
2026-04-30T10:30:49
273 info drive_resolved Searching Asana fields for Google Drive URL 2026-04-30T10:30:49
274 info drive_resolved Resolved Drive folder (8 items, 7 in CAD/)
payload
{
  "cad_folder_id": "1QSubAYKQtku-FjHGZL0Y7rTqCilfizul",
  "folder_id": "1lcO5aA-VkQ3sJlAZh7r_jXH5laQHAcX_"
}
2026-04-30T10:30:50
275 info pdf_downloaded Picking the latest-dated plan-set PDF 2026-04-30T10:30:50
276 info pdf_downloaded Downloaded plan-set: Teresa Ramirez_V0_12-16-2025.pdf (8.2 MB)
payload
{
  "bytes": 8555492,
  "filename": "Teresa Ramirez_V0_12-16-2025.pdf"
}
2026-04-30T10:30:52
277 info bom_downloaded Looking for the BOM CSV in the same folder 2026-04-30T10:30:52
278 warn bom_downloaded No BOM CSV in folder — modules section will rely on PDF + Asana only 2026-04-30T10:30:52
279 info ai_extracted Extracting text from the plan-set PDF 2026-04-30T10:30:52
280 info ai_extracted Pass 1/3: Claude Opus 4.7 (full extraction) 2026-04-30T10:30:58
281 info ai_extracted Pass 1: Opus filled 70 fields (avg 87%) 2026-04-30T10:32:21
282 info ai_extracted Pass 2/3: Claude Sonnet 4.6 retrying 49 missing fields 2026-04-30T10:32:21
283 info ai_extracted Pass 2: Sonnet added 36 more fields 2026-04-30T10:33:50
284 info ai_extracted Pass 3/3: Claude Opus 4.7 final retry on 13 stubborn fields 2026-04-30T10:33:50
285 info ai_extracted Extracted 106 fields, avg confidence 82% (Opus: 70, Sonnet retry: +36, 13 still unfilled)
payload
{
  "avg_confidence": 0.829,
  "extra_fields": 0,
  "fields": 106,
  "missing": 13,
  "passes": {
    "opus_full": 70,
    "opus_retry": 0,
    "sonnet_retry": 36
  },
  "usage": {
    "cache_creation_input_tokens": 9323,
    "cache_read_input_tokens": 0,
    "input_tokens": 78912,
    "output_tokens": 12596
  }
}
2026-04-30T10:34:00
286 info awaiting_review Pipeline complete — review the extracted fields and submit when ready 2026-04-30T10:34:00
287 info submitting Building SolarAPP+ payload from reviewed fields 2026-04-30T10:38:44
288 info submitting Calling SolarAPP+ create_project + PATCH /details 2026-04-30T10:38:44
289 error submitting SolarAPP+ rejected the submission: HTTP 500 | path=/api/v1/projects/ba91588f-48a1-45b9-84d0-e360c6161764/details | Server Error 2026-04-30T10:38:59
290 info submitting Building SolarAPP+ payload from reviewed fields 2026-04-30T11:03:36
291 info submitting Calling SolarAPP+ create_project + PATCH /details 2026-04-30T11:03:36
292 error submitting SolarAPP+ rejected the submission: HTTP 500 | path=/api/v1/projects/115adcff-5f24-4c98-a5e4-19ee9a42a1f3/details | Server Error 2026-04-30T11:05:02

Field values (106)

Show all extracted + edited fields
Key AI value User value Conf Edited In map
Attachment points staggered No No 0.55 yes yes
Backup contains service disconnect Yes Yes 0.75 yes yes
Backup device manufacturer Tesla Tesla 0.95 yes yes
Backup device model Backup Switch Backup Switch 0.90 yes yes
Backup device OCPD rating (Amps) 60 60 0.85 yes yes
Backup feeder conductor material Copper Copper 0.85 yes yes
Busbar #1 already present on site Yes Yes 0.90 yes yes
Busbar #1 interconnection compliance method 120% rule 120% rule 0.85 yes yes
Busbar #1 main panel upgrade No No 0.95 yes yes
Busbar #1 number of branch circuit breakers 1 1 0.55 yes yes
Busbar #1 on line side of main service panel No No 0.85 yes yes
Busbar #1 panel type Main Service Panel Main Service Panel 0.90 yes yes
Busbar #1 rating (Amps) 200 200 0.95 yes yes
Busbar #1 subject to backfeed Yes Yes 0.85 yes yes
Busbar feeder interconnection compliance method 705.12(B)(2) 0.80 no yes
Busbar feeder max THWN-2 conductors in raceway 3 3 0.90 yes yes
Busbar feeder OCPD rating (Amps) 70 70 0.85 yes yes
Busbar feeder wire gauge (AWG) 4 4 0.90 yes yes
Combiner panel contains ESS Yes Yes 0.75 yes yes
Combiner panel has dedicated OCPD Yes Yes 0.85 yes yes
Combiner panel interconnection location New Subpanel New Subpanel 0.90 yes yes
Current roof covering material Asphalt or composition shingles Asphalt or composition shingles 0.95 yes yes
Each ESS unit has dedicated OCPD Yes Yes 0.70 yes yes
ESS assembly weight (lbs) 291 291 0.88 yes yes
ESS center of mass less than 4 feet from floor Yes Yes 0.80 yes yes
ESS in sleeping rooms or closets opening to sleeping rooms No No 0.90 yes yes
ESS installation location Outdoor walls Outdoor walls 0.85 yes yes
ESS location subject to vehicle damage No No 0.60 yes yes
ESS Model 1 includes DC-coupled expansion unit No No 0.80 yes yes
ESS Model 1 Manufacturer Tesla Tesla 0.98 yes yes
ESS Model 1 Number 1707000-11-J-DOM 1707000-11-J-DOM 0.95 yes yes
ESS Model 1 Quantity 1 1 0.98 yes yes
ESS positively attached to building per manufacturer Yes Yes 0.90 yes yes
ESS + PV Inverter certified as single unit (no field wiring) Yes Yes 0.85 yes yes
ESS subject to vehicle damage (alternate) No No 0.65 yes yes
ESS unit charging from grid Yes Yes 0.90 yes yes
ESS unit has dedicated OCPD Yes Yes 0.80 yes yes
ESS unit installation location (architecture: Energy Storage System) Outdoor walls Outdoor walls 0.85 yes yes
ESS unit interconnection location New Subpanel New Subpanel 0.70 yes yes
ESS unit is single unit with inverter Yes Yes 0.95 yes yes
ESS unit manufacturer (architecture: Energy Storage System) Tesla Tesla 0.95 yes yes
ESS unit model (architecture: Energy Storage System) 1707000-11-J-DOM 1707000-11-J-DOM 0.90 yes yes
ESS unit OCPD rating (Amps) 60 60 0.90 yes yes
ESS unit quantity (architecture: Energy Storage System) 1 1 0.95 yes yes
ESS units have separation less than 3 feet (alternate) No No 0.75 yes yes
Flush mount or tilt-up Flush mount Flush mount 0.90 yes yes
Home has sprinkler systems No No 0.50 yes yes
Homeowner Full Name Teresa Ramirez Teresa Ramirez 0.98 yes yes
Inverter 1 interconnection location New Subpanel New Subpanel 0.80 yes yes
Inverter 1 Manufacturer Tesla Tesla 0.98 yes yes
Inverter 1 Model Number 1707000-11-J-DOM 1707000-11-J-DOM 0.95 yes yes
Inverter 1 OCPD rating (Amps) 60 60 0.95 yes yes
Inverter 1 power setting (kW) 11.5 11.5 0.95 yes yes
Inverter architecture type String Inverter without DC-DC Converters String Inverter without DC-DC Converters 0.70 yes yes
Inverter output uses NM cable No No 0.75 yes yes
Main breaker derate applied No No 0.75 yes yes
Max DC PV Wire / USE-2 conductors in raceway (excl. EGC) 4 4 0.85 yes yes
Max DC THWN-2 conductors in raceway (excl. EGC) 4 4 0.70 yes yes
Maximum distance from module to roof (inches) 10 10 0.60 yes yes
Maximum input DC open circuit voltage (Voc) of PV inverter 600.0 600.0 0.90 yes yes
Maximum input DC short circuit current (Isc) of PV inverter 19.0 19.0 0.85 yes yes
Maximum number of modules in a DC series string 7 7 0.90 yes yes
Maximum OCPD rating allowed on Inverter 1 (Amps) 60 60 0.85 yes yes
Maximum spacing between adjacent attachment points (inches) 48 48 0.95 yes yes
Module 1 Quantity 13 13 0.98 yes yes
Module fire rating type 1 1 0.85 yes yes
Module is bifacial No No 0.85 yes yes
Module Manufacturer Q CELLS Q CELLS 0.95 yes yes
Module Model Number Q.PEAK DUO BLK ML-G10.C+ 410 Q.PEAK DUO BLK ML-G10.C+ 410 0.95 yes yes
Number of busbars 2 2 0.70 yes yes
Number of composite shingle layers 1 1 0.50 yes yes
Number of distinct ESS models 1 1 0.90 yes yes
OCPD fault current compliance methods Utility available fault current not greater than 10 kA Utility available fault current not greater than 10 kA 0.50 yes yes
OCPD protecting busbar #1 rating (Amps) 70 70 0.95 yes yes
Power production compliance method Inverter-based generation Inverter-based generation 0.60 yes yes
Project Address 248 Mount Arbor St, McFarland, CA 93250 248 Mount Arbor St, McFarland, CA 93250 0.95 yes yes
Project valuation (USD) 43296 43296 0.85 yes yes
PV system weight (lbs/sq ft) 4.0 4.0 0.55 yes yes
Racking System Manufacturer Unirac Unirac 0.95 yes yes
Racking System Model Number NXT UMOUNT NXT UMOUNT 0.90 yes yes
Rafter depth (inches) 3.5 3.5 0.65 yes yes
Rafter has ceiling joists No No 0.70 yes yes
Rafter largest span (feet) 24.0 24.0 0.45 yes yes
Rafter size (nominal) 2x4 2x4 0.95 yes yes
Rafter spacing (inches) 24 24 0.95 yes yes
Rafter type Engineered truss Engineered truss 0.90 yes yes
Rapid Shutdown compliance method inside array Module-level rapid shutdown via Tesla MCI-2S mid-circuit interrupters Module-level rapid shutdown via Tesla MCI-2S mid-circuit interrupters 0.80 yes yes
Rapid Shutdown Device Manufacturer Tesla Tesla 0.98 yes yes
Rapid Shutdown Device Model Number MCI-2S MCI-2S 0.95 yes yes
Rapid Shutdown Device Quantity 5 5 0.95 yes yes
Roof framing type Truss Truss 0.90 yes yes
Roof has flat plane No No 0.85 yes yes
Roof penetration sealant method name and description Unirac Stronghold Butyl attachment with pre-applied butyl pad seal Unirac Stronghold Butyl attachment with pre-applied butyl pad seal 0.85 yes yes
Roof pitch 4/12 4/12 0.70 yes yes
Roof plane height of at least 20% of array Yes Yes 0.60 yes yes
Separation between ESS units less than 3 feet No No 0.85 yes yes
Smoke/heat alarm present at ESS location Yes Yes 0.60 yes yes
Storage architecture Energy Storage System Energy Storage System 0.85 yes yes
Supply side connection per NEC 705.12(A) No No 0.85 yes yes
THWN-2 conductors in PV inverter AC output circuit raceway (excl. EGC) 3 3 0.85 yes yes
Total roof area (sq ft) 1884 1884 0.85 yes yes
Using Power Control System to curtail Inverter 1 No No 0.70 yes yes
Utility available fault current greater than 10 kA at service No No 0.55 yes yes
Utility company name Southern California Edison Southern California Edison 0.90 yes yes
Utility service feed rating (Amps) 200 200 0.95 yes yes
Whole home backup Yes Yes 0.95 yes yes

Artifacts (3)

Kind Path Size SHA
asana_json /data/runs/01KQEZ1WGDPQ6NZ0WRYX3Q7X9Q/asana.json 39033 B
pdf /data/runs/01KQEZ1WGDPQ6NZ0WRYX3Q7X9Q/pdf/Teresa_Ramirez_V0_12-16-2025.pdf 8555492 B 41acb4f7fafc1047
extraction /data/runs/01KQEZ1WGDPQ6NZ0WRYX3Q7X9Q/extraction.json 51618 B