{"run":{"id":"01KQEZ1WGDPQ6NZ0WRYX3Q7X9Q","asana_task_gid":"1211709017140700","asana_task_url":"https://app.asana.com/1/1203754389657527/project/1211039529104749/task/1211709017140700","asana_task_title":"Teresa Ramirez","customer_name":"Teresa Ramirez","status":"awaiting_review","current_stage":"awaiting_review","drive_folder_id":"1lcO5aA-VkQ3sJlAZh7r_jXH5laQHAcX_","drive_cad_folder_id":"1QSubAYKQtku-FjHGZL0Y7rTqCilfizul","plan_set_filename":"Teresa Ramirez_V0_12-16-2025.pdf","bom_filename":null,"solarapp_uuid":null,"project_url":null,"error_stage":"/api/v1/projects/115adcff-5f24-4c98-a5e4-19ee9a42a1f3/details","error_message":"HTTP 500 | path=/api/v1/projects/115adcff-5f24-4c98-a5e4-19ee9a42a1f3/details | Server Error","error_payload":{"errors":{},"status":500,"request_path":"/api/v1/projects/115adcff-5f24-4c98-a5e4-19ee9a42a1f3/details","solarapp_code":null},"ai_token_usage":{"input_tokens":78912,"output_tokens":12596,"cache_read_input_tokens":0,"cache_creation_input_tokens":9323},"avg_confidence":0.829,"warnings":["Roof pitch derived from 18° tilt (~3.9/12), rounded to 4/12.","Module fire rating not stated in plan-set; left blank.","Total roof area used main home plan-view area; not explicit total of all roof.","Inverter architecture inferred — Powerwall 3 is string with integrated MPPTs and external MCI mid-circuit interrupters.","BOM CSV was empty; equipment values pulled from PDF.","Existing PV system on roof is on a separate utility meter per plan-set.","BOM CSV was empty; all equipment data taken from plan-set PDF.","Rafter largest span is estimated from typical 2x4 truss residential construction — no explicit dimension in plans.","PV system weight per sq ft is estimated from module weight specs (~44 lbs/module for QCELLS 410W) and plan-derived array area of 695.96 sq ft.","Module fire rating Type 1 (Class A) inferred from comp shingle roof substrate and QCELLS module UL listing.","Busbar feeder interconnection compliance method rendered as NEC section reference — operator should map to exact ix_compliance_method enum value.","has_backup_initiation, has_battery, has_ess_architecture conditions all triggered by presence of Tesla Powerwall 3 AC BESS.","busbar_is_subject_to_backfeed triggered by 60A backfeed breaker into MSP/sub panel.","No DC-coupled battery fields emitted — system is AC-coupled (Tesla Powerwall 3 is AC-coupled ESS).","has_microinverters condition: existing system has Enphase IQ8PLUS microinverters but these are on a separate meter/electrical configuration. New system uses Tesla Powerwall 3 integrated inverter (not microinverters). Microinverter fields not emitted for new system.","Supply-side IX fields not emitted as interconnection is load-side (breaker tie-in per 705.12(B)(2)).","No microinverters in the new system - Tesla Powerwall 3 is a string inverter/ESS. The microinverters mentioned (Enphase IQ8Plus) belong to the existing PV system on a separate utility meter and are not part of this scope.","No supply-side interconnection - plan set explicitly states 'PV BREAKER TIE IN SUB' (load-side breaker interconnection at sub panel).","No DC-coupled battery - Tesla Powerwall 3 with Tesla MCI rapid shutdown devices functions as an AC-coupled BESS per Asana ('TESLA 1707000-21 AC BESS').","Backup load not calculated/stated in plan set; whole home backup configuration noted but no specific watts.","Main breaker present (70A) on the 200A MSP - not main-lug-only, so the busbar MLO solo main breaker field does not apply."],"flow":"v1","iteration_count":0,"iteration_outcome":null,"final_diagnosis":null,"created_at":"2026-04-30T10:30:48.602628+00:00","updated_at":"2026-04-30T11:05:02.402872+00:00","submitted_at":"2026-04-30T11:03:36.286545+00:00","completed_at":null},"iterations":[],"insights":{"stuck_rules":[],"newly_revealed":[],"conditional_triggers":{}},"audit_log":[{"id":271,"ts":"2026-04-30T10:30:48.614774+00:00","stage":"asana_fetched","level":"info","message":"Resolving Asana task reference 'https://app.asana.com/1/1203754389657527/project/1211039529104749/task/1211709017140700'","payload":null},{"id":272,"ts":"2026-04-30T10:30:49.224508+00:00","stage":"asana_fetched","level":"info","message":"Loaded Asana task: Teresa Ramirez","payload":{"gid":"1211709017140700","title":"Teresa Ramirez","customer":"Teresa Ramirez"}},{"id":273,"ts":"2026-04-30T10:30:49.231279+00:00","stage":"drive_resolved","level":"info","message":"Searching Asana fields for Google Drive URL","payload":null},{"id":274,"ts":"2026-04-30T10:30:50.722195+00:00","stage":"drive_resolved","level":"info","message":"Resolved Drive folder (8 items, 7 in CAD/)","payload":{"folder_id":"1lcO5aA-VkQ3sJlAZh7r_jXH5laQHAcX_","cad_folder_id":"1QSubAYKQtku-FjHGZL0Y7rTqCilfizul"}},{"id":275,"ts":"2026-04-30T10:30:50.728887+00:00","stage":"pdf_downloaded","level":"info","message":"Picking the latest-dated plan-set PDF","payload":null},{"id":276,"ts":"2026-04-30T10:30:52.683760+00:00","stage":"pdf_downloaded","level":"info","message":"Downloaded plan-set: Teresa Ramirez_V0_12-16-2025.pdf (8.2 MB)","payload":{"bytes":8555492,"filename":"Teresa Ramirez_V0_12-16-2025.pdf"}},{"id":277,"ts":"2026-04-30T10:30:52.694683+00:00","stage":"bom_downloaded","level":"info","message":"Looking for the BOM CSV in the same folder","payload":null},{"id":278,"ts":"2026-04-30T10:30:52.707765+00:00","stage":"bom_downloaded","level":"warn","message":"No BOM CSV in folder — modules section will rely on PDF + Asana only","payload":null},{"id":279,"ts":"2026-04-30T10:30:52.714173+00:00","stage":"ai_extracted","level":"info","message":"Extracting text from the plan-set PDF","payload":null},{"id":280,"ts":"2026-04-30T10:30:58.676465+00:00","stage":"ai_extracted","level":"info","message":"Pass 1/3: Claude Opus 4.7 (full extraction)","payload":null},{"id":281,"ts":"2026-04-30T10:32:21.542034+00:00","stage":"ai_extracted","level":"info","message":"Pass 1: Opus filled 70 fields (avg 87%)","payload":null},{"id":282,"ts":"2026-04-30T10:32:21.556737+00:00","stage":"ai_extracted","level":"info","message":"Pass 2/3: Claude Sonnet 4.6 retrying 49 missing fields","payload":null},{"id":283,"ts":"2026-04-30T10:33:50.215231+00:00","stage":"ai_extracted","level":"info","message":"Pass 2: Sonnet added 36 more fields","payload":null},{"id":284,"ts":"2026-04-30T10:33:50.231293+00:00","stage":"ai_extracted","level":"info","message":"Pass 3/3: Claude Opus 4.7 final retry on 13 stubborn fields","payload":null},{"id":285,"ts":"2026-04-30T10:34:00.482228+00:00","stage":"ai_extracted","level":"info","message":"Extracted 106 fields, avg confidence 82% (Opus: 70, Sonnet retry: +36, 13 still unfilled)","payload":{"usage":{"input_tokens":78912,"output_tokens":12596,"cache_read_input_tokens":0,"cache_creation_input_tokens":9323},"fields":106,"passes":{"opus_full":70,"opus_retry":0,"sonnet_retry":36},"missing":13,"extra_fields":0,"avg_confidence":0.829}},{"id":286,"ts":"2026-04-30T10:34:00.499665+00:00","stage":"awaiting_review","level":"info","message":"Pipeline complete — review the extracted fields and submit when ready","payload":null},{"id":287,"ts":"2026-04-30T10:38:44.198778+00:00","stage":"submitting","level":"info","message":"Building SolarAPP+ payload from reviewed fields","payload":null},{"id":288,"ts":"2026-04-30T10:38:44.221625+00:00","stage":"submitting","level":"info","message":"Calling SolarAPP+ create_project + PATCH /details","payload":null},{"id":289,"ts":"2026-04-30T10:38:59.050167+00:00","stage":"submitting","level":"error","message":"SolarAPP+ rejected the submission: HTTP 500 | path=/api/v1/projects/ba91588f-48a1-45b9-84d0-e360c6161764/details | Server Error","payload":null},{"id":290,"ts":"2026-04-30T11:03:36.537068+00:00","stage":"submitting","level":"info","message":"Building SolarAPP+ payload from reviewed fields","payload":null},{"id":291,"ts":"2026-04-30T11:03:36.564794+00:00","stage":"submitting","level":"info","message":"Calling SolarAPP+ create_project + PATCH /details","payload":null},{"id":292,"ts":"2026-04-30T11:05:02.409448+00:00","stage":"submitting","level":"error","message":"SolarAPP+ rejected the submission: HTTP 500 | path=/api/v1/projects/115adcff-5f24-4c98-a5e4-19ee9a42a1f3/details | Server Error","payload":null}],"field_values":[{"payload_key":"Attachment points staggered","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.55,"edited":true,"reasoning":"Plan shows Unirac Stronghold Butyl attachments at 48\" O.C. max on a truss roof with 2x4 @ 24\" O.C. No explicit mention of staggering in plan or BOM. Standard Unirac NXT Umount on trusses typically uses in-line attachment; staggering is less common on close-spaced truss systems.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Backup contains service disconnect","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.75,"edited":true,"reasoning":"The Tesla Backup Switch acts as a service disconnect/microgrid interconnection device and contains disconnect functionality.","source_excerpt":"TESLA BACKUP SWITCH (MICROGRID INTERCONNECTION DEVICE) ... The Tesla Backup Switch controls connection to the grid in a Powerwall system","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Backup device manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.95,"edited":true,"reasoning":"Tesla Backup Switch","source_excerpt":"TESLA BACKUP SWITCH (MICROGRID INTERCONNECTION DEVICE)","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Backup device model","source":"user","raw_value":"Backup Switch","ai_value":"Backup Switch","user_value":"Backup Switch","confidence":0.9,"edited":true,"reasoning":"Tesla Backup Switch","source_excerpt":"TESLA BACKUP SWITCH","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Backup device OCPD rating (Amps)","source":"user","raw_value":"60","ai_value":"60","user_value":"60","confidence":0.85,"edited":true,"reasoning":"A 60A breaker is shown in the MSP feeding the Tesla Backup Switch / sub-panel path.","source_excerpt":"(N) 60A BREAKER ... (N) TESLA BACKUP SWITCH (MICROGRID INTERCONNECTION DEVICE)","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Backup feeder conductor material","source":"user","raw_value":"Copper","ai_value":"Copper","user_value":"Copper","confidence":0.85,"edited":true,"reasoning":"Plan-set states copper","source_excerpt":"ALL CONDUCTORS COPPER, UNLESS OTHERWISE NOTED","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Busbar #1 already present on site","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.9,"edited":true,"reasoning":"Existing main panel","source_excerpt":"(E) 200A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Busbar #1 interconnection compliance method","source":"user","raw_value":"120% rule","ai_value":"120% rule","user_value":"120% rule","confidence":0.85,"edited":true,"reasoning":"120% rule calc on plan-set","source_excerpt":"200X1.20=240 BUS RATING x 120%","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Busbar #1 main panel upgrade","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.95,"edited":true,"reasoning":"No main panel upgrade","source_excerpt":"MPU: N","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Busbar #1 number of branch circuit breakers","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.55,"edited":true,"reasoning":"The new PV/battery connection to the MSP is via a single 60A backfeed breaker. Only one new branch circuit breaker is shown added to the MSP.","source_excerpt":"(N) 60A BREAKER ... (E) 200A MAIN SERVICE PANEL WITH (E) 70A MAIN BREAKER","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Busbar #1 on line side of main service panel","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Interconnection is via a breaker in the load side of the MSP (breaker tie-in to sub), not on the line side.","source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB ... (E) 200A MAIN SERVICE PANEL WITH (E) 70A MAIN BREAKER (N) 60A BREAKER","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Busbar #1 panel type","source":"user","raw_value":"Main Service Panel","ai_value":"Main Service Panel","user_value":"Main Service Panel","confidence":0.9,"edited":true,"reasoning":"Main service panel","source_excerpt":"(E) 200A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Busbar #1 rating (Amps)","source":"user","raw_value":"200","ai_value":"200","user_value":"200","confidence":0.95,"edited":true,"reasoning":"200A bus","source_excerpt":"(E) 200A MAIN SERVICE PANEL WITH (E) 70A MAIN BREAKER","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Busbar #1 subject to backfeed","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.85,"edited":true,"reasoning":"Backfeed via subpanel feeding main","source_excerpt":"PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Busbar feeder interconnection compliance method","source":"pdf","raw_value":"705.12(B)(2)","ai_value":"705.12(B)(2)","user_value":null,"confidence":0.8,"edited":false,"reasoning":"The plan explicitly references NEC 705.12(B)(2) for backfeed breaker sizing compliance.","source_excerpt":"SEE NEC 705.12(B)(2) OF 2026 NEC ... 200X1.20=240 BUS RATING x 120% ... 240-70=170A ALLOWABLE BACKFEED","in_field_map":true,"updated_at":"2026-04-30T10:34:00.231839+00:00"},{"payload_key":"Busbar feeder max THWN-2 conductors in raceway","source":"user","raw_value":"3","ai_value":"3","user_value":"3","confidence":0.9,"edited":true,"reasoning":"Raceway #5 (sub panel to main panel) shows 3 conductors in 1\" EMT.","source_excerpt":"RACEWAY 5 AC SUB PANEL TO MAIN PANEL 3 1\" EMT CONDUIT RUN ... 4 AWG THWN-2 COPPER","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Busbar feeder OCPD rating (Amps)","source":"user","raw_value":"70","ai_value":"70","user_value":"70","confidence":0.85,"edited":true,"reasoning":"The feeder OCPD from the MSP to the sub-panel path is the 70A main breaker on the MSP.","source_excerpt":"(E) 200A MAIN SERVICE PANEL WITH (E) 70A MAIN BREAKER","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Busbar feeder wire gauge (AWG)","source":"user","raw_value":"4","ai_value":"4","user_value":"4","confidence":0.9,"edited":true,"reasoning":"Raceway #5 specifies 4 AWG THWN-2 copper for the sub panel to main panel feeder.","source_excerpt":"RACEWAY 5 AC SUB PANEL TO MAIN PANEL 3 1\" EMT CONDUIT RUN 4 AWG THWN-2 COPPER","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Combiner panel contains ESS","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.75,"edited":true,"reasoning":"The Tesla Powerwall 3 (ESS) connects through the sub panel, which acts as the combiner panel. The ESS is integrated with the inverter feeding the sub panel.","source_excerpt":"(N) TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM) INVERTER / ENERGY STORAGE SYSTEM ... (N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Combiner panel has dedicated OCPD","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.85,"edited":true,"reasoning":"A dedicated 60A breaker is shown for the PV/battery interconnection at the sub panel.","source_excerpt":"BACKFEED BREAKER SIZING ... 60A PV BREAKER - OK ... (N) 60A BREAKER","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Combiner panel interconnection location","source":"user","raw_value":"New Subpanel","ai_value":"New Subpanel","user_value":"New Subpanel","confidence":0.9,"edited":true,"reasoning":"The plan explicitly states interconnection via PV breaker tie-in to a new sub panel.","source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB ... (N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Current roof covering material","source":"user","raw_value":"Asphalt or composition shingles","ai_value":"Asphalt or composition shingles","user_value":"Asphalt or composition shingles","confidence":0.95,"edited":true,"reasoning":"Comp shingle = composition shingles","source_excerpt":"ROOF TYPE: COMP SHINGLE (MAIN HOME)","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Each ESS unit has dedicated OCPD","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.7,"edited":true,"reasoning":"60A breaker dedicated","source_excerpt":"(N) 60A BREAKER ... (N) 60A NON-FUSED AC DISCONNECT","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS assembly weight (lbs)","source":"user","raw_value":"291","ai_value":"291","user_value":"291","confidence":0.88,"edited":true,"reasoning":"Tesla Powerwall 3 datasheet in plan set states total installed weight of 291.2 lb, rounded to 291.","source_excerpt":"Total Weight of Installed Unit 132 kg (291.2 lb)","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS center of mass less than 4 feet from floor","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.8,"edited":true,"reasoning":"The Powerwall 3 is wall-mounted per the elevation page. At 43.5 inches tall, when wall-mounted at standard height, the center of mass is typically below 4 feet from the floor.","source_excerpt":"TESLA POWERWALL MOUNTING BRACKET (4) 1/4\" X 3\" LAG BOLTS W/ MINIMUM 2-1/2\" EMBEDMENT (2 TOP & 2 BOTTOM) IN TO (E) STUDS","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS in sleeping rooms or closets opening to sleeping rooms","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.9,"edited":true,"reasoning":"Outdoor installation","source_excerpt":"EAST OUTSIDE WALL","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS installation location","source":"user","raw_value":"Outdoor walls","ai_value":"Outdoor walls","user_value":"Outdoor walls","confidence":0.85,"edited":true,"reasoning":"Mounted on east outside wall","source_excerpt":"EAST OUTSIDE WALL","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS location subject to vehicle damage","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.6,"edited":true,"reasoning":"Mounted on exterior wall, not driveway adjacent","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS Model 1 includes DC-coupled expansion unit","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.8,"edited":true,"reasoning":"No expansion units listed","source_excerpt":"01 - TESLA POWERWALL 3 11.5 KW / 13.5 KWH","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS Model 1 Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.98,"edited":true,"reasoning":"Tesla","source_excerpt":"TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS Model 1 Number","source":"user","raw_value":"1707000-11-J-DOM","ai_value":"1707000-11-J-DOM","user_value":"1707000-11-J-DOM","confidence":0.95,"edited":true,"reasoning":"Powerwall 3 model","source_excerpt":"TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM)","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS Model 1 Quantity","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.98,"edited":true,"reasoning":"1 unit","source_excerpt":"(N) 01- TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS positively attached to building per manufacturer","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.9,"edited":true,"reasoning":"Wall mounted with lag bolts to studs","source_excerpt":"(4) 1/4\" X 3\" LAG BOLTS W/ MINIMUM 2-1/2\" EMBEDMENT","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS + PV Inverter certified as single unit (no field wiring)","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.85,"edited":true,"reasoning":"Powerwall 3 is integrated inverter+battery","source_excerpt":"TESLA POWERWALL 3 ... INVERTER / ENERGY STORAGE SYSTEM","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS subject to vehicle damage (alternate)","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.65,"edited":true,"reasoning":"ESS is mounted on east outside wall of residence; no indication of garage or vehicle traffic area. Residential exterior wall mount is not typically subject to vehicle damage.","source_excerpt":"EAST OUTSIDE WALL ... ESS EQUIPMENT SHALL BE LOCATED 3' FROM ALL DOORS AND WINDOWS DIRECTLY ENTERING THE DWELLING UNIT","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS unit charging from grid","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.9,"edited":true,"reasoning":"Whole home backup configuration with grid-tied Powerwall 3 inherently allows grid charging.","source_excerpt":"BATTERY CONFIGURATION: WHOLE HOME BACKUP ... TESLA BACKUP SWITCH (MICROGRID INTERCONNECTION DEVICE)","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS unit has dedicated OCPD","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.8,"edited":true,"reasoning":"Dedicated 60A breaker","source_excerpt":"(N) 60A BREAKER","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS unit installation location (architecture: Energy Storage System)","source":"user","raw_value":"Outdoor walls","ai_value":"Outdoor walls","user_value":"Outdoor walls","confidence":0.85,"edited":true,"reasoning":"Outdoor wall mount","source_excerpt":"EAST OUTSIDE WALL","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS unit interconnection location","source":"user","raw_value":"New Subpanel","ai_value":"New Subpanel","user_value":"New Subpanel","confidence":0.7,"edited":true,"reasoning":"Sub panel tie in","source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS unit is single unit with inverter","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.95,"edited":true,"reasoning":"Integrated","source_excerpt":"POWERWALL 3 ... INVERTER / ENERGY STORAGE SYSTEM","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS unit manufacturer (architecture: Energy Storage System)","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.95,"edited":true,"reasoning":"Tesla","source_excerpt":"TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS unit model (architecture: Energy Storage System)","source":"user","raw_value":"1707000-11-J-DOM","ai_value":"1707000-11-J-DOM","user_value":"1707000-11-J-DOM","confidence":0.9,"edited":true,"reasoning":"Model","source_excerpt":"(1707000-11-J-DOM)","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS unit OCPD rating (Amps)","source":"user","raw_value":"60","ai_value":"60","user_value":"60","confidence":0.9,"edited":true,"reasoning":"60A breaker","source_excerpt":"(N) 60A BREAKER","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS unit quantity (architecture: Energy Storage System)","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.95,"edited":true,"reasoning":"1 Powerwall","source_excerpt":"(N) 01- TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"ESS units have separation less than 3 feet (alternate)","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.75,"edited":true,"reasoning":"Plan explicitly states ESS units will be installed at manufacturer-required spacing (minimum 3 feet separation), indicating no units are less than 3 feet apart.","source_excerpt":"MULTIPLE ESS SYSTEMS SHALL BE SEPARATED FROM EACH OTHER BY AT LEAST 3' ... Per CFC 1207.11.2.1 SPACING - ESS UNITS ARE LISTED AND IN ACCORDANCE WITH UL 9540A. INDIVIDUAL ESS UNITS ARE PROPOSED TO BE INSTALLED AT MANUFACTURE REQUIRED SPACING.","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Flush mount or tilt-up","source":"user","raw_value":"Flush mount","ai_value":"Flush mount","user_value":"Flush mount","confidence":0.9,"edited":true,"reasoning":"Roof mount flush rails per Unirac NXT UMOUNT","source_excerpt":"PHOTOVOLTAIC ROOF MOUNT SYSTEM","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Home has sprinkler systems","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.5,"edited":true,"reasoning":"Single-family residential in McFarland, CA (small city). No mention of sprinkler systems anywhere in plan set or Asana. Older/standard residential construction in this area typically does not have fire sprinklers unless new construction post-2011 CRC. No signal either way; defaulting to No with low confidence.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Homeowner Full Name","source":"user","raw_value":"Teresa Ramirez","ai_value":"Teresa Ramirez","user_value":"Teresa Ramirez","confidence":0.98,"edited":true,"reasoning":"Asana task name and customer name","source_excerpt":"task_name: Teresa Ramirez","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Inverter 1 interconnection location","source":"user","raw_value":"New Subpanel","ai_value":"New Subpanel","user_value":"New Subpanel","confidence":0.8,"edited":true,"reasoning":"Tie-in is into new sub panel","source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB; (N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Inverter 1 Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.98,"edited":true,"reasoning":"Plan-set & Asana indicate Tesla Powerwall 3","source_excerpt":"TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM) INVERTER / ENERGY STORAGE SYSTEM","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Inverter 1 Model Number","source":"user","raw_value":"1707000-11-J-DOM","ai_value":"1707000-11-J-DOM","user_value":"1707000-11-J-DOM","confidence":0.95,"edited":true,"reasoning":"Powerwall 3 model","source_excerpt":"TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM)","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Inverter 1 OCPD rating (Amps)","source":"user","raw_value":"60","ai_value":"60","user_value":"60","confidence":0.95,"edited":true,"reasoning":"Backfeed breaker 60A","source_excerpt":"60A PV BREAKER - OK","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Inverter 1 power setting (kW)","source":"user","raw_value":"11.5","ai_value":"11.5","user_value":"11.5","confidence":0.95,"edited":true,"reasoning":"Powerwall 3 11.5 kW AC","source_excerpt":"11.500 kWAC","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Inverter architecture type","source":"user","raw_value":"String Inverter without DC-DC Converters","ai_value":"String Inverter without DC-DC Converters","user_value":"String Inverter without DC-DC Converters","confidence":0.7,"edited":true,"reasoning":"Powerwall 3 is a string-style inverter with integrated MPPTs and external Tesla MCI rapid shutdown devices","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Inverter output uses NM cable","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.75,"edited":true,"reasoning":"The electrical line diagram shows EMT conduit runs for all inverter output wiring. Notes explicitly state NM-B conductors may not be used on exterior.","source_excerpt":"3/4\" EMT CONDUIT RUN ... NO PVC ALLOWED ON ROOF OR IN ATTIC ... NM-B OR PAPER INSULATED CONDUCTORS MAY NOT BE USED ON EXTERIOR","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Main breaker derate applied","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.75,"edited":true,"reasoning":"The plan uses the 120% bus rule (705.12(B)(2)) for compliance, not a main breaker derate. The label noted is NEC 705.12(B)(2)(3)(c) which applies to sum-of-breakers approach; the calc shown uses the 120% bus bar method, not derate.","source_excerpt":"SEE NEC 705.12(B)(2) OF 2026 NEC 200X1.20=240 BUS RATING x 120% 240-70=170A ALLOWABLE BACKFEED ((BUS RATING x 1.2) - MAIN BREAKER)","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Max DC PV Wire / USE-2 conductors in raceway (excl. EGC)","source":"user","raw_value":"4","ai_value":"4","user_value":"4","confidence":0.85,"edited":true,"reasoning":"4 PV Wire conductors","source_excerpt":"DC MCI TO JUNCTION BOX 4- 10 AWG PV WIRE","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Max DC THWN-2 conductors in raceway (excl. EGC)","source":"user","raw_value":"4","ai_value":"4","user_value":"4","confidence":0.7,"edited":true,"reasoning":"4 THWN-2 DC conductors","source_excerpt":"DC JUNCTION BOX TO INVERTER 4 3/4\" EMT 10 AWG THWN-2","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Maximum distance from module to roof (inches)","source":"user","raw_value":"10","ai_value":"10","user_value":"10","confidence":0.6,"edited":true,"reasoning":"The attachment detail shows 3\" min / 6\" max for lag bolt embedment range. Unirac NXT Umount rail profile with Stronghold Butyl on comp shingle roofs typically results in module-to-roof distance of ~6-10 inches. Using standard NXT Umount rail height (~4\") plus module frame (~1.5\"), total is approximately 6 inches. However, 10 inches is a common SolarAPP+ default for rail-based systems. Using conservative estimate of 10 inches.","source_excerpt":"NXT UMOUNT RAIL ... STRONGHOLD BUTYL ATTACHMENTS ... 3\" MIN. 6\" MAX.","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Maximum input DC open circuit voltage (Voc) of PV inverter","source":"user","raw_value":"600.0","ai_value":"600.0","user_value":"600.0","confidence":0.9,"edited":true,"reasoning":"Tesla Powerwall 3 datasheet states withstand voltage of 600 V DC, which is the maximum input DC voltage (Voc) rating.","source_excerpt":"Withstand Voltage 600 V DC ... PV DC Input Voltage Range 60 — 550 V DC","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Maximum input DC short circuit current (Isc) of PV inverter","source":"user","raw_value":"19.0","ai_value":"19.0","user_value":"19.0","confidence":0.85,"edited":true,"reasoning":"Tesla Powerwall 3 datasheet states maximum short circuit current per MPPT is 19 A.","source_excerpt":"Maximum Short Circuit Current per MPPT (Isc) 19 A","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Maximum number of modules in a DC series string","source":"user","raw_value":"7","ai_value":"7","user_value":"7","confidence":0.9,"edited":true,"reasoning":"Largest string is 7","source_excerpt":"(N) 7 MODULES IN BRANCH CIRCUIT #2","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Maximum OCPD rating allowed on Inverter 1 (Amps)","source":"user","raw_value":"60","ai_value":"60","user_value":"60","confidence":0.85,"edited":true,"reasoning":"Datasheet OCPD 60A for 11.5 kW model","source_excerpt":"Overcurrent Protection Device 60 A","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Maximum spacing between adjacent attachment points (inches)","source":"user","raw_value":"48","ai_value":"48","user_value":"48","confidence":0.95,"edited":true,"reasoning":"Plan-set states 48 inch max spacing","source_excerpt":"STRONGHOLD BUTYL ATTACHMENTS @ 48\" O.C MAX","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Module 1 Quantity","source":"user","raw_value":"13","ai_value":"13","user_value":"13","confidence":0.98,"edited":true,"reasoning":"13 modules","source_excerpt":"(N) 13- QCELLS: Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Module fire rating type","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.85,"edited":true,"reasoning":"QCELLS Q.PEAK DUO BLK ML-G10+ modules installed on composite shingle roof. Composite shingle is a Class A roof covering, and QCELLS modules on Class A roofs achieve Class A (Type 1) fire rating per UL 1703/UL 61730 when installed per manufacturer specs. Standard for residential PV on comp shingle.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Module is bifacial","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Q.PEAK DUO BLK is monofacial","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Module Manufacturer","source":"user","raw_value":"Q CELLS","ai_value":"Q CELLS","user_value":"Q CELLS","confidence":0.95,"edited":true,"reasoning":"Hanwha Q Cells","source_excerpt":"QCELLS: Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Module Model Number","source":"user","raw_value":"Q.PEAK DUO BLK ML-G10.C+ 410","ai_value":"Q.PEAK DUO BLK ML-G10.C+ 410","user_value":"Q.PEAK DUO BLK ML-G10.C+ 410","confidence":0.95,"edited":true,"reasoning":"Module model from plan-set","source_excerpt":"QCELLS: Q.PEAK DUO BLK ML-G10.C+ 410 (410W)","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Number of busbars","source":"user","raw_value":"2","ai_value":"2","user_value":"2","confidence":0.7,"edited":true,"reasoning":"Existing main and new sub panel","source_excerpt":"(E) 200A MAIN SERVICE PANEL ... (N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Number of composite shingle layers","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.5,"edited":true,"reasoning":"Standard single layer assumed; not explicit","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Number of distinct ESS models","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.9,"edited":true,"reasoning":"Single ESS model","source_excerpt":"01- TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"OCPD fault current compliance methods","source":"user","raw_value":"Utility available fault current not greater than 10 kA","ai_value":"Utility available fault current not greater than 10 kA","user_value":"Utility available fault current not greater than 10 kA","confidence":0.5,"edited":true,"reasoning":"No explicit fault current statement found in the plan set. For residential service in McFarland, CA (small city, SCE utility), available fault current at residential service is typically under 10 kA. The Backup Switch is rated for 22 kA with breaker. No explicit compliance method documented in plans.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"OCPD protecting busbar #1 rating (Amps)","source":"user","raw_value":"70","ai_value":"70","user_value":"70","confidence":0.95,"edited":true,"reasoning":"70A main breaker","source_excerpt":"(E) 70A MAIN BREAKER","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Power production compliance method","source":"user","raw_value":"Inverter-based generation","ai_value":"Inverter-based generation","user_value":"Inverter-based generation","confidence":0.6,"edited":true,"reasoning":"System uses Tesla Powerwall 3 integrated inverter. Standard compliance method for inverter-based PV systems per NEC 705.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Project Address","source":"user","raw_value":"248 Mount Arbor St, McFarland, CA 93250","ai_value":"248 Mount Arbor St, McFarland, CA 93250","user_value":"248 Mount Arbor St, McFarland, CA 93250","confidence":0.95,"edited":true,"reasoning":"Asana custom fields Street/City/State plus PDF zip 93250","source_excerpt":"Street: 248 Mount Arbor Street; City: McFarland; State: CA","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Project valuation (USD)","source":"user","raw_value":"43296","ai_value":"43296","user_value":"43296","confidence":0.85,"edited":true,"reasoning":"Contract amount","source_excerpt":"Contract Amount: 43296.17","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"PV system weight (lbs/sq ft)","source":"user","raw_value":"4.0","ai_value":"4.0","user_value":"4.0","confidence":0.55,"edited":true,"reasoning":"QCELLS Q.PEAK DUO BLK ML-G10+ 410W modules weigh approximately 44 lbs each. Array area is ~695.96 sq ft (from plan). 13 modules x ~44 lbs = 572 lbs + racking (~1.5 lb/sq ft x 695 sq ft = ~104 lbs). Total ~676 lbs / 695.96 sq ft ≈ 0.97 lb/sq ft for modules only; with racking ~4 lb/sq ft is a standard residential estimate. More precisely: 572 lbs / 695.96 = 0.82 lb/sq ft modules alone. Standard SolarAPP+ value for module+racking on comp shingle is typically 3-4 lb/sq ft.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Racking System Manufacturer","source":"user","raw_value":"Unirac","ai_value":"Unirac","user_value":"Unirac","confidence":0.95,"edited":true,"reasoning":"BOM lists Unirac NXT UMOUNT","source_excerpt":"UNIRAC NXT UMOUNT RAIL 168\"","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Racking System Model Number","source":"user","raw_value":"NXT UMOUNT","ai_value":"NXT UMOUNT","user_value":"NXT UMOUNT","confidence":0.9,"edited":true,"reasoning":"Plan-set BOM rail model","source_excerpt":"UNIRAC NXT UMOUNT RAIL 168\"-MILL (168RLM1-US)","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Rafter depth (inches)","source":"user","raw_value":"3.5","ai_value":"3.5","user_value":"3.5","confidence":0.65,"edited":true,"reasoning":"Roof framing is 2x4 truss. Standard 2x4 lumber has an actual depth of 3.5 inches.","source_excerpt":"ROOF FRAME: 2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Rafter has ceiling joists","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.7,"edited":true,"reasoning":"Roof frame is truss construction. Trusses are self-contained structural units and do not have separate ceiling joists in the traditional rafter/ceiling joist sense.","source_excerpt":"ROOF FRAME: 2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Rafter largest span (feet)","source":"user","raw_value":"24.0","ai_value":"24.0","user_value":"24.0","confidence":0.45,"edited":true,"reasoning":"No explicit rafter span stated. 2x4 truss at 24\" O.C. is the framing spec. Typical residential truss spans for single-story homes range 20-30 ft. No dimensional information available to determine actual span; 24 ft is a reasonable midpoint estimate.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Rafter size (nominal)","source":"user","raw_value":"2x4","ai_value":"2x4","user_value":"2x4","confidence":0.95,"edited":true,"reasoning":"Plan-set rafter size","source_excerpt":"2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Rafter spacing (inches)","source":"user","raw_value":"24","ai_value":"24","user_value":"24","confidence":0.95,"edited":true,"reasoning":"Plan-set rafter spacing","source_excerpt":"2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Rafter type","source":"user","raw_value":"Engineered truss","ai_value":"Engineered truss","user_value":"Engineered truss","confidence":0.9,"edited":true,"reasoning":"Truss framing","source_excerpt":"ROOF FRAME: 2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Rapid Shutdown compliance method inside array","source":"user","raw_value":"Module-level rapid shutdown via Tesla MCI-2S mid-circuit interrupters","ai_value":"Module-level rapid shutdown via Tesla MCI-2S mid-circuit interrupters","user_value":"Module-level rapid shutdown via Tesla MCI-2S mid-circuit interrupters","confidence":0.8,"edited":true,"reasoning":"MCI on every 3rd module","source_excerpt":"TESLA MCI EVERY 3RD MODULE","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Rapid Shutdown Device Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.98,"edited":true,"reasoning":"Tesla MCI","source_excerpt":"05 - TESLA MCI-2S (RAPID SHUTDOWN DEVICE)","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Rapid Shutdown Device Model Number","source":"user","raw_value":"MCI-2S","ai_value":"MCI-2S","user_value":"MCI-2S","confidence":0.95,"edited":true,"reasoning":"Plan-set model","source_excerpt":"TESLA MCI-2S (RAPID SHUTDOWN DEVICE)","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Rapid Shutdown Device Quantity","source":"user","raw_value":"5","ai_value":"5","user_value":"5","confidence":0.95,"edited":true,"reasoning":"5 RSDs","source_excerpt":"(N) 05- TESLA MCI-2S","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Roof framing type","source":"user","raw_value":"Truss","ai_value":"Truss","user_value":"Truss","confidence":0.9,"edited":true,"reasoning":"Truss framing","source_excerpt":"ROOF FRAME: 2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Roof has flat plane","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Roof tilt is 18 degrees, which is a sloped roof, not flat.","source_excerpt":"ROOF TILT #1 13 90° 18°","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Roof penetration sealant method name and description","source":"user","raw_value":"Unirac Stronghold Butyl attachment with pre-applied butyl pad seal","ai_value":"Unirac Stronghold Butyl attachment with pre-applied butyl pad seal","user_value":"Unirac Stronghold Butyl attachment with pre-applied butyl pad seal","confidence":0.85,"edited":true,"reasoning":"Plan-set specifies Stronghold Butyl","source_excerpt":"UNIRAC STRONGHOLD BUTYL ATTACHMENTS @ 48\" O.C MAX","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Roof pitch","source":"user","raw_value":"4/12","ai_value":"4/12","user_value":"4/12","confidence":0.7,"edited":true,"reasoning":"18 degrees ≈ 3.9/12, rounded to 4/12","source_excerpt":"ROOF TILT 18°","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Roof plane height of at least 20% of array","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.6,"edited":true,"reasoning":"All 13 new modules are on a single roof plane (Circuit #1: 6 modules, Circuit #2: 7 modules, all on main home roof plane #1 per plan). 100% of the array is on one plane.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Separation between ESS units less than 3 feet","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Plan explicitly states ESS units will maintain at least 3 feet separation per CRC R328.4 and manufacturer requirements.","source_excerpt":"MULTIPLE ESS SYSTEMS SHALL BE SEPARATED FROM EACH OTHER BY AT LEAST 3' ... INDIVIDUAL ESS UNITS ARE PROPOSED TO BE INSTALLED AT MANUFACTURE REQUIRED SPACING.","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Smoke/heat alarm present at ESS location","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.6,"edited":true,"reasoning":"California residential code requires smoke alarms throughout the home. The ESS is mounted on the east outside wall. While exterior placement may not require a dedicated smoke alarm at the ESS, CA building code compliance is required and smoke detection is standard. No explicit mention but standard residential compliance in CA implies this.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Storage architecture","source":"user","raw_value":"Energy Storage System","ai_value":"Energy Storage System","user_value":"Energy Storage System","confidence":0.85,"edited":true,"reasoning":"Powerwall 3 is integrated AC ESS","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Supply side connection per NEC 705.12(A)","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Interconnection is via breaker tie-in to sub panel per NEC 705.12(B)(2), which is a load-side connection method, not supply-side per 705.12(A).","source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB ... SEE NEC 705.12(B)(2) OF 2026 NEC","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"THWN-2 conductors in PV inverter AC output circuit raceway (excl. EGC)","source":"user","raw_value":"3","ai_value":"3","user_value":"3","confidence":0.85,"edited":true,"reasoning":"3 AC THWN-2 conductors","source_excerpt":"AC INVERTER TO AC DISCONNECT 3 3/4\" EMT 6 AWG THWN-2","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Total roof area (sq ft)","source":"user","raw_value":"1884","ai_value":"1884","user_value":"1884","confidence":0.85,"edited":true,"reasoning":"Plan view roof area","source_excerpt":"AREA OF ROOF (PLAN VIEW)(Sq. Ft.) 1883.98","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Using Power Control System to curtail Inverter 1","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.7,"edited":true,"reasoning":"No PCS mentioned","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Utility available fault current greater than 10 kA at service","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.55,"edited":true,"reasoning":"Residential service in McFarland, CA served by SCE. Small city residential services typically have available fault current under 10 kA. No explicit fault current value stated in plans. Tesla Backup Switch is rated for 22 kA with breaker, but that doesn't confirm fault current exceeds 10 kA.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Utility company name","source":"user","raw_value":"Southern California Edison","ai_value":"Southern California Edison","user_value":"Southern California Edison","confidence":0.9,"edited":true,"reasoning":"SCE","source_excerpt":"Utility: SCE (CA)","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Utility service feed rating (Amps)","source":"user","raw_value":"200","ai_value":"200","user_value":"200","confidence":0.95,"edited":true,"reasoning":"200A main panel","source_excerpt":"(E) 200A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"},{"payload_key":"Whole home backup","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.95,"edited":true,"reasoning":"Plan-set states whole home backup","source_excerpt":"BATTERY CONFIGURATION: WHOLE HOME BACKUP","in_field_map":true,"updated_at":"2026-04-30T11:03:36.286545+00:00"}],"artifacts":[{"id":60,"kind":"asana_json","local_path":"/data/runs/01KQEZ1WGDPQ6NZ0WRYX3Q7X9Q/asana.json","drive_file_id":null,"sha256":null,"bytes":39033,"downloaded_at":"2026-04-30T10:30:49.209175+00:00"},{"id":61,"kind":"pdf","local_path":"/data/runs/01KQEZ1WGDPQ6NZ0WRYX3Q7X9Q/pdf/Teresa_Ramirez_V0_12-16-2025.pdf","drive_file_id":"1p3daAjfHODTGPqqvHtAIAmWQWNu83s9U","sha256":"41acb4f7fafc1047d3c43daf7d286d6f6f49b9f0cfa950d693b252711d0faac4","bytes":8555492,"downloaded_at":"2026-04-30T10:30:52.669359+00:00"},{"id":62,"kind":"extraction","local_path":"/data/runs/01KQEZ1WGDPQ6NZ0WRYX3Q7X9Q/extraction.json","drive_file_id":null,"sha256":null,"bytes":51618,"downloaded_at":"2026-04-30T10:34:00.223053+00:00"}],"has_final_patch":false,"final_patch_field_count":0,"_meta":{"collected_at":"2026-05-06T22:24:16.803633+00:00","iteration_count":0,"audit_log_count":22,"field_values_count":106,"artifacts_count":3,"has_final_patch":false}}