← back to audit · 01KQ9T8AF16RM3BZMVB77WSE0Q

Daniel Martinez Noriega

Daniel Martinez Noriega
Asana ↗ v1 awaiting_review stage=awaiting_review iters=0 conf=86%
Download JSON

Patches (downloadable JSON)

No patches recorded yet. Run hasn't reached the iteration loop.

Iteration history (0)

No iterations recorded (run hasn't reached the loop, or this is a v1 run).

Audit log (12 events)

# Level Stage Message Time
3 info asana_fetched Resolving Asana task reference '1214016163628485' 2026-04-28T10:30:44
4 info asana_fetched Loaded Asana task: Daniel Martinez Noriega
payload
{
  "customer": "Daniel Martinez Noriega",
  "gid": "1214016163628485",
  "title": "Daniel Martinez Noriega"
}
2026-04-28T10:30:44
5 info drive_resolved Searching Asana fields for Google Drive URL 2026-04-28T10:30:44
6 info drive_resolved Resolved Drive folder (5 items, 4 in CAD/)
payload
{
  "cad_folder_id": "1c5s9FE-i_5SxibhGGDKpc0xd8vnRVHHL",
  "folder_id": "1An0edHhDk5tFVtXUV4hK9COsZrXz6ys4"
}
2026-04-28T10:30:46
7 info pdf_downloaded Picking the latest-dated plan-set PDF 2026-04-28T10:30:46
8 info pdf_downloaded Downloaded plan-set: Daniel Martinez Noriega_LGCY_V5_04-23-2026.pdf (6.2 MB)
payload
{
  "bytes": 6514576,
  "filename": "Daniel Martinez Noriega_LGCY_V5_04-23-2026.pdf"
}
2026-04-28T10:30:49
9 info bom_downloaded Looking for the BOM CSV in the same folder 2026-04-28T10:30:49
10 info bom_downloaded Downloaded BOM: BOM_LIS56437.csv (20 rows)
payload
{
  "filename": "BOM_LIS56437.csv",
  "rows": 20
}
2026-04-28T10:30:49
11 info ai_extracted Extracting text from the plan-set PDF 2026-04-28T10:30:49
12 info ai_extracted Calling Claude Opus 4.7 to extract structured fields 2026-04-28T10:30:52
13 info ai_extracted Extracted 49 fields, avg confidence 86%
payload
{
  "avg_confidence": 0.861,
  "extra_fields": 0,
  "fields": 49,
  "usage": {
    "cache_creation_input_tokens": 5191,
    "cache_read_input_tokens": 0,
    "input_tokens": 35316,
    "output_tokens": 4361
  }
}
2026-04-28T10:31:47
14 info awaiting_review Pipeline complete — review the extracted fields and submit when ready 2026-04-28T10:31:47

Field values (49)

Show all extracted + edited fields
Key AI value User value Conf Edited In map
Busbar #1 already present on site Yes 0.90 no yes
Busbar #1 rating (Amps) 200 0.95 no yes
Busbar #1 subject to backfeed Yes 0.70 no yes
Current roof covering material Asphalt or composition shingles 0.97 no yes
Each ESS unit has dedicated OCPD Yes 0.70 no yes
ESS installation location Outdoor walls 0.60 no yes
ESS Model 1 includes DC-coupled expansion unit No 0.90 no yes
ESS Model 1 Manufacturer Tesla 0.98 no yes
ESS Model 1 Number Powerwall 3 0.97 no yes
ESS Model 1 Quantity 1 0.98 no yes
ESS positively attached to building per manufacturer Yes 0.85 no yes
ESS + PV Inverter certified as single unit (no field wiring) Yes 0.85 no yes
Flush mount or tilt-up Flush mount 0.90 no yes
Home has sprinkler systems No 0.95 no yes
Homeowner Full Name Daniel Martinez Noriega 0.98 no yes
Inverter 1 interconnection location Existing Subpanel 0.70 no yes
Inverter 1 Manufacturer Tesla 0.98 no yes
Inverter 1 Model Number Powerwall 3 0.95 no yes
Inverter 1 OCPD rating (Amps) 60 0.95 no yes
Inverter 1 power setting (kW) 11.5 0.95 no yes
Inverter architecture type String Inverter without DC-DC Converters 0.60 no yes
Max DC PV Wire / USE-2 conductors in raceway (excl. EGC) 4 0.80 no yes
Max DC THWN-2 conductors in raceway (excl. EGC) 4 0.80 no yes
Maximum distance from module to roof (inches) 6 0.85 no yes
Maximum input DC open circuit voltage (Voc) of PV inverter 600 0.92 no yes
Maximum input DC short circuit current (Isc) of PV inverter 19 0.90 no yes
Maximum number of modules in a DC series string 8 0.90 no yes
Maximum OCPD rating allowed on Inverter 1 (Amps) 60 0.90 no yes
Module 1 Quantity 15 0.99 no yes
Module is bifacial No 0.85 no yes
Module Manufacturer Qcells 0.98 no yes
Module Model Number Q.PEAK DUO BLK ML-G10.C+ 410 0.97 no yes
Number of busbars 2 0.70 no yes
Number of composite shingle layers 1 0.50 no yes
Number of distinct ESS models 1 0.95 no yes
OCPD protecting busbar #1 rating (Amps) 200 0.90 no yes
Racking System Manufacturer SnapNrack 0.97 no yes
Racking System Model Number Ultra Rail UR-45 0.92 no yes
Rapid Shutdown compliance method inside array PV Hazard Control System listed to UL 3741 0.70 no yes
Rapid Shutdown Device Manufacturer Tesla 0.97 no yes
Rapid Shutdown Device Model Number MCI-2 0.97 no yes
Roof penetration sealant method name and description SnapNrack UltraFoot Deck with SpeedSeal+ pre-applied butyl pad 0.85 no yes
Roof pitch 1.5/12 0.60 no yes
Smoke/heat alarm present at ESS location Yes 0.60 no yes
Supply side connection per NEC 705.12(A) No 0.85 no yes
THWN-2 conductors in PV inverter AC output circuit raceway (excl. EGC) 3 0.85 no yes
Total roof area (sq ft) 1739 0.85 no yes
Using Power Control System to curtail Inverter 1 Yes 0.90 no yes
Utility service feed rating (Amps) 200 0.95 no yes

Artifacts (4)

Kind Path Size SHA
asana_json /data/runs/01KQ9T8AF16RM3BZMVB77WSE0Q/asana.json 55126 B
pdf /data/runs/01KQ9T8AF16RM3BZMVB77WSE0Q/pdf/Daniel_Martinez_Noriega_LGCY_V5_04-23-2026.pdf 6514576 B 45f5dfe4628b3a5a
bom /data/runs/01KQ9T8AF16RM3BZMVB77WSE0Q/bom/BOM_LIS56437.csv 2156 B 88a4931866e8ec52
extraction /data/runs/01KQ9T8AF16RM3BZMVB77WSE0Q/extraction.json 22320 B