{"run":{"id":"01KQ9T8AF16RM3BZMVB77WSE0Q","asana_task_gid":"1214016163628485","asana_task_url":"https://app.asana.com/1/1203754389657527/project/1207873459369363/task/1214016163628485","asana_task_title":"Daniel Martinez Noriega","customer_name":"Daniel Martinez Noriega","status":"awaiting_review","current_stage":"awaiting_review","drive_folder_id":"1An0edHhDk5tFVtXUV4hK9COsZrXz6ys4","drive_cad_folder_id":"1c5s9FE-i_5SxibhGGDKpc0xd8vnRVHHL","plan_set_filename":"Daniel Martinez Noriega_LGCY_V5_04-23-2026.pdf","bom_filename":"BOM_LIS56437.csv","solarapp_uuid":null,"project_url":null,"error_stage":null,"error_message":null,"error_payload":null,"ai_token_usage":{"input_tokens":35316,"output_tokens":4361,"cache_read_input_tokens":0,"cache_creation_input_tokens":5191},"avg_confidence":0.861,"warnings":["Roof pitch derived from 7° tilt (~1.5/12); operator should verify exact pitch","ESS install location inferred as outdoor wall - not explicitly stated","Module bifacial status inferred from model line (Q.PEAK DUO BLK is monofacial)","Two busbars assumed: existing 200A MSP and new 125A subpanel; reviewer should confirm which is the actual interconnection point","Inverter architecture: Powerwall 3 is integrated string inverter; MCI-2 devices are PVRSE rapid-shutdown only, not DC-DC optimizers","Number of composite shingle layers not stated; default 1 is a guess"],"flow":"v1","iteration_count":0,"iteration_outcome":null,"final_diagnosis":null,"created_at":"2026-04-28T10:30:44.450585+00:00","updated_at":"2026-04-28T10:31:47.774008+00:00","submitted_at":null,"completed_at":null},"iterations":[],"insights":{"stuck_rules":[],"newly_revealed":[],"conditional_triggers":{}},"audit_log":[{"id":3,"ts":"2026-04-28T10:30:44.460474+00:00","stage":"asana_fetched","level":"info","message":"Resolving Asana task reference '1214016163628485'","payload":null},{"id":4,"ts":"2026-04-28T10:30:44.980357+00:00","stage":"asana_fetched","level":"info","message":"Loaded Asana task: Daniel Martinez Noriega","payload":{"gid":"1214016163628485","title":"Daniel Martinez Noriega","customer":"Daniel Martinez Noriega"}},{"id":5,"ts":"2026-04-28T10:30:44.986774+00:00","stage":"drive_resolved","level":"info","message":"Searching Asana fields for Google Drive URL","payload":null},{"id":6,"ts":"2026-04-28T10:30:46.573696+00:00","stage":"drive_resolved","level":"info","message":"Resolved Drive folder (5 items, 4 in CAD/)","payload":{"folder_id":"1An0edHhDk5tFVtXUV4hK9COsZrXz6ys4","cad_folder_id":"1c5s9FE-i_5SxibhGGDKpc0xd8vnRVHHL"}},{"id":7,"ts":"2026-04-28T10:30:46.587125+00:00","stage":"pdf_downloaded","level":"info","message":"Picking the latest-dated plan-set PDF","payload":null},{"id":8,"ts":"2026-04-28T10:30:49.245756+00:00","stage":"pdf_downloaded","level":"info","message":"Downloaded plan-set: Daniel Martinez Noriega_LGCY_V5_04-23-2026.pdf (6.2 MB)","payload":{"bytes":6514576,"filename":"Daniel Martinez Noriega_LGCY_V5_04-23-2026.pdf"}},{"id":9,"ts":"2026-04-28T10:30:49.254617+00:00","stage":"bom_downloaded","level":"info","message":"Looking for the BOM CSV in the same folder","payload":null},{"id":10,"ts":"2026-04-28T10:30:49.898273+00:00","stage":"bom_downloaded","level":"info","message":"Downloaded BOM: BOM_LIS56437.csv (20 rows)","payload":{"rows":20,"filename":"BOM_LIS56437.csv"}},{"id":11,"ts":"2026-04-28T10:30:49.905014+00:00","stage":"ai_extracted","level":"info","message":"Extracting text from the plan-set PDF","payload":null},{"id":12,"ts":"2026-04-28T10:30:52.281807+00:00","stage":"ai_extracted","level":"info","message":"Calling Claude Opus 4.7 to extract structured fields","payload":null},{"id":13,"ts":"2026-04-28T10:31:47.767382+00:00","stage":"ai_extracted","level":"info","message":"Extracted 49 fields, avg confidence 86%","payload":{"usage":{"input_tokens":35316,"output_tokens":4361,"cache_read_input_tokens":0,"cache_creation_input_tokens":5191},"fields":49,"extra_fields":0,"avg_confidence":0.861}},{"id":14,"ts":"2026-04-28T10:31:47.781866+00:00","stage":"awaiting_review","level":"info","message":"Pipeline complete — review the extracted fields and submit when ready","payload":null}],"field_values":[{"payload_key":"Busbar #1 already present on site","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.9,"edited":false,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Busbar #1 rating (Amps)","source":"pdf","raw_value":"200","ai_value":"200","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Busbar #1 subject to backfeed","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.7,"edited":false,"reasoning":null,"source_excerpt":"PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Current roof covering material","source":"pdf","raw_value":"Asphalt or composition shingles","ai_value":"Asphalt or composition shingles","user_value":null,"confidence":0.97,"edited":false,"reasoning":null,"source_excerpt":"ROOF MATERIAL: COMP SHINGLE","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Each ESS unit has dedicated OCPD","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.7,"edited":false,"reasoning":null,"source_excerpt":"(N) 60A BREAKER ... Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"ESS installation location","source":"inferred","raw_value":"Outdoor walls","ai_value":"Outdoor walls","user_value":null,"confidence":0.6,"edited":false,"reasoning":"AC disconnect noted as on south outside wall; ESS adjacent","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"ESS Model 1 includes DC-coupled expansion unit","source":"bom","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.9,"edited":false,"reasoning":"BOM lists only Powerwall 3, no Expansion unit","source_excerpt":"Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"ESS Model 1 Manufacturer","source":"bom","raw_value":"Tesla","ai_value":"Tesla","user_value":null,"confidence":0.98,"edited":false,"reasoning":null,"source_excerpt":"Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"ESS Model 1 Number","source":"bom","raw_value":"Powerwall 3","ai_value":"Powerwall 3","user_value":null,"confidence":0.97,"edited":false,"reasoning":null,"source_excerpt":"Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"ESS Model 1 Quantity","source":"pdf","raw_value":"1","ai_value":"1","user_value":null,"confidence":0.98,"edited":false,"reasoning":null,"source_excerpt":"(N) 1- TESLA: POWERWALL 3","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"ESS positively attached to building per manufacturer","source":"inferred","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.85,"edited":false,"reasoning":"Standard manufacturer-compliant wall mount","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"ESS + PV Inverter certified as single unit (no field wiring)","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.85,"edited":false,"reasoning":null,"source_excerpt":"POWERWALL 3 ... ENERGY STORAGE SYSTEM INTEGRATED INVERTER","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Flush mount or tilt-up","source":"pdf","raw_value":"Flush mount","ai_value":"Flush mount","user_value":null,"confidence":0.9,"edited":false,"reasoning":null,"source_excerpt":"PHOTOVOLTAIC ROOF MOUNT SYSTEM","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Home has sprinkler systems","source":"pdf","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"Sprinklers: No","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Homeowner Full Name","source":"asana","raw_value":"Daniel Martinez Noriega","ai_value":"Daniel Martinez Noriega","user_value":null,"confidence":0.98,"edited":false,"reasoning":null,"source_excerpt":"Customer Name: Daniel Martinez Noriega","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Inverter 1 interconnection location","source":"pdf","raw_value":"Existing Subpanel","ai_value":"Existing Subpanel","user_value":null,"confidence":0.7,"edited":false,"reasoning":null,"source_excerpt":"INTERCONNECTION: BREAKER TIE-IN AT SUBPANEL","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Inverter 1 Manufacturer","source":"bom","raw_value":"Tesla","ai_value":"Tesla","user_value":null,"confidence":0.98,"edited":false,"reasoning":null,"source_excerpt":"Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Inverter 1 Model Number","source":"bom","raw_value":"Powerwall 3","ai_value":"Powerwall 3","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"Tesla Powerwall 3 (1707000-XX-Y)","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Inverter 1 OCPD rating (Amps)","source":"pdf","raw_value":"60","ai_value":"60","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"(N) 60A BREAKER","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Inverter 1 power setting (kW)","source":"pdf","raw_value":"11.5","ai_value":"11.5","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"SYSTEM SIZE AC: 1x 11500W= 11.500 kWAC","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Inverter architecture type","source":"inferred","raw_value":"String Inverter without DC-DC Converters","ai_value":"String Inverter without DC-DC Converters","user_value":null,"confidence":0.6,"edited":false,"reasoning":"Powerwall 3 is integrated string inverter with MCI rapid shutdown (not DC optimizers)","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Max DC PV Wire / USE-2 conductors in raceway (excl. EGC)","source":"pdf","raw_value":"4","ai_value":"4","user_value":null,"confidence":0.8,"edited":false,"reasoning":null,"source_excerpt":"MCI TO JUNCTION BOX 4- 10 AWG PV WIRE","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Max DC THWN-2 conductors in raceway (excl. EGC)","source":"pdf","raw_value":"4","ai_value":"4","user_value":null,"confidence":0.8,"edited":false,"reasoning":null,"source_excerpt":"JUNCTION BOX TO TESLA POWERWALL 3 4 ... 10 AWG THWN-2","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Maximum distance from module to roof (inches)","source":"pdf","raw_value":"6","ai_value":"6","user_value":null,"confidence":0.85,"edited":false,"reasoning":null,"source_excerpt":"3\" MIN. 6\" MAX.","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Maximum input DC open circuit voltage (Voc) of PV inverter","source":"pdf","raw_value":"600","ai_value":"600","user_value":null,"confidence":0.92,"edited":false,"reasoning":null,"source_excerpt":"Withstand Voltage 600 V DC","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Maximum input DC short circuit current (Isc) of PV inverter","source":"pdf","raw_value":"19","ai_value":"19","user_value":null,"confidence":0.9,"edited":false,"reasoning":null,"source_excerpt":"Maximum Short Circuit Current per MPPT (Isc) 19 A","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Maximum number of modules in a DC series string","source":"pdf","raw_value":"8","ai_value":"8","user_value":null,"confidence":0.9,"edited":false,"reasoning":null,"source_excerpt":"(N) 8 MODULES IN BRANCH CIRCUIT #1","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Maximum OCPD rating allowed on Inverter 1 (Amps)","source":"pdf","raw_value":"60","ai_value":"60","user_value":null,"confidence":0.9,"edited":false,"reasoning":null,"source_excerpt":"Overcurrent Protection Device 60 A","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Module 1 Quantity","source":"bom","raw_value":"15","ai_value":"15","user_value":null,"confidence":0.99,"edited":false,"reasoning":null,"source_excerpt":"15 ... QCELLS Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Module is bifacial","source":"inferred","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.85,"edited":false,"reasoning":"Q.PEAK DUO BLK ML-G10.C+ is a monofacial black module","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Module Manufacturer","source":"bom","raw_value":"Qcells","ai_value":"Qcells","user_value":null,"confidence":0.98,"edited":false,"reasoning":null,"source_excerpt":"QCELLS Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Module Model Number","source":"bom","raw_value":"Q.PEAK DUO BLK ML-G10.C+ 410","ai_value":"Q.PEAK DUO BLK ML-G10.C+ 410","user_value":null,"confidence":0.97,"edited":false,"reasoning":null,"source_excerpt":"QCELLS Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Number of busbars","source":"pdf","raw_value":"2","ai_value":"2","user_value":null,"confidence":0.7,"edited":false,"reasoning":"Existing 200A MSP busbar plus new 125A subpanel busbar","source_excerpt":"(E) 200A MAIN SERVICE PANEL ... (N) 125A SUB PANEL","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Number of composite shingle layers","source":"inferred","raw_value":"1","ai_value":"1","user_value":null,"confidence":0.5,"edited":false,"reasoning":"Single layer assumed; not stated explicitly","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Number of distinct ESS models","source":"bom","raw_value":"1","ai_value":"1","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"OCPD protecting busbar #1 rating (Amps)","source":"pdf","raw_value":"200","ai_value":"200","user_value":null,"confidence":0.9,"edited":false,"reasoning":null,"source_excerpt":"(E) 200A MAIN BREAKER","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Racking System Manufacturer","source":"bom","raw_value":"SnapNrack","ai_value":"SnapNrack","user_value":null,"confidence":0.97,"edited":false,"reasoning":null,"source_excerpt":"SnapNrack Domestic UR-45 172\" Rail","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Racking System Model Number","source":"pdf","raw_value":"Ultra Rail UR-45","ai_value":"Ultra Rail UR-45","user_value":null,"confidence":0.92,"edited":false,"reasoning":null,"source_excerpt":"(N) SNAPNRACK UR-45 RAIL","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Rapid Shutdown compliance method inside array","source":"pdf","raw_value":"PV Hazard Control System listed to UL 3741","ai_value":"PV Hazard Control System listed to UL 3741","user_value":null,"confidence":0.7,"edited":false,"reasoning":null,"source_excerpt":"UL 3741 ... PVRSE ... PVRSA","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Rapid Shutdown Device Manufacturer","source":"bom","raw_value":"Tesla","ai_value":"Tesla","user_value":null,"confidence":0.97,"edited":false,"reasoning":null,"source_excerpt":"Tesla MCI-2","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Rapid Shutdown Device Model Number","source":"bom","raw_value":"MCI-2","ai_value":"MCI-2","user_value":null,"confidence":0.97,"edited":false,"reasoning":null,"source_excerpt":"Tesla MCI-2","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Roof penetration sealant method name and description","source":"pdf","raw_value":"SnapNrack UltraFoot Deck with SpeedSeal+ pre-applied butyl pad","ai_value":"SnapNrack UltraFoot Deck with SpeedSeal+ pre-applied butyl pad","user_value":null,"confidence":0.85,"edited":false,"reasoning":null,"source_excerpt":"SpeedSeal+ Technology, a pre-installed butyl pad","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Roof pitch","source":"pdf","raw_value":"1.5/12","ai_value":"1.5/12","user_value":null,"confidence":0.6,"edited":false,"reasoning":"7° tilt converts to ~1.5/12 pitch (tan(7°)*12=1.47)","source_excerpt":"ROOF TILT 7°","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Smoke/heat alarm present at ESS location","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.6,"edited":false,"reasoning":null,"source_excerpt":"INTERCONNECTED SMOKE ALARMS ARE REQUIRED TO BE INSTALLED","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Supply side connection per NEC 705.12(A)","source":"pdf","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.85,"edited":false,"reasoning":null,"source_excerpt":"INTERCONNECTION: BREAKER TIE-IN AT SUBPANEL","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"THWN-2 conductors in PV inverter AC output circuit raceway (excl. EGC)","source":"pdf","raw_value":"3","ai_value":"3","user_value":null,"confidence":0.85,"edited":false,"reasoning":null,"source_excerpt":"TESLA POWERWALL 3 TO AC DISCONNECT 3 ... 6 AWG THWN-2","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Total roof area (sq ft)","source":"pdf","raw_value":"1739","ai_value":"1739","user_value":null,"confidence":0.85,"edited":false,"reasoning":null,"source_excerpt":"AREA OF ROOF (PLAN VIEW)(Sq. Ft.) 1739.21","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Using Power Control System to curtail Inverter 1","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.9,"edited":false,"reasoning":null,"source_excerpt":"PANEL LIMIT FEATURE FOR THE POWERWALL UNIT(S) TO BE UTILIZED ... PCS CONTROLLED CURRENT SETTING: 100A","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"},{"payload_key":"Utility service feed rating (Amps)","source":"pdf","raw_value":"200","ai_value":"200","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER","in_field_map":true,"updated_at":"2026-04-28T10:31:47.636449+00:00"}],"artifacts":[{"id":1,"kind":"asana_json","local_path":"/data/runs/01KQ9T8AF16RM3BZMVB77WSE0Q/asana.json","drive_file_id":null,"sha256":null,"bytes":55126,"downloaded_at":"2026-04-28T10:30:44.951963+00:00"},{"id":2,"kind":"pdf","local_path":"/data/runs/01KQ9T8AF16RM3BZMVB77WSE0Q/pdf/Daniel_Martinez_Noriega_LGCY_V5_04-23-2026.pdf","drive_file_id":"1BkqR8GvfC1e7dXHPZE7LE_NIMIPbzWDA","sha256":"45f5dfe4628b3a5ac83d8d74b57248432f8bc0286985b6f7f28e3c4358820a60","bytes":6514576,"downloaded_at":"2026-04-28T10:30:49.231150+00:00"},{"id":3,"kind":"bom","local_path":"/data/runs/01KQ9T8AF16RM3BZMVB77WSE0Q/bom/BOM_LIS56437.csv","drive_file_id":"1vENN8VK7BFuo4waOJcU6CHh4nQS1YaId","sha256":"88a4931866e8ec52e8fa6e37350af0d6fe132e277d7f2d5099072206e66f52b1","bytes":2156,"downloaded_at":"2026-04-28T10:30:49.881875+00:00"},{"id":4,"kind":"extraction","local_path":"/data/runs/01KQ9T8AF16RM3BZMVB77WSE0Q/extraction.json","drive_file_id":null,"sha256":null,"bytes":22320,"downloaded_at":"2026-04-28T10:31:47.628872+00:00"}],"has_final_patch":false,"final_patch_field_count":0,"_meta":{"collected_at":"2026-05-06T22:20:18.965186+00:00","iteration_count":0,"audit_log_count":12,"field_values_count":49,"artifacts_count":4,"has_final_patch":false}}