| Attachment points staggered |
Yes |
— |
0.50 |
no |
yes |
| Backup contains service disconnect |
Yes |
— |
0.70 |
no |
yes |
| Backup device manufacturer |
Tesla |
— |
0.95 |
no |
yes |
| Backup device model |
Backup Switch |
— |
0.90 |
no |
yes |
| Backup device OCPD rating (Amps) |
200 |
— |
0.75 |
no |
yes |
| Backup feeder conductor material |
Copper |
— |
0.90 |
no |
yes |
| Busbar #1 already present on site |
Yes |
— |
0.95 |
no |
yes |
| Busbar #1 interconnection compliance method |
120% rule |
— |
0.85 |
no |
yes |
| Busbar #1 main-lug-only solo main breaker present |
No |
— |
0.72 |
no |
yes |
| Busbar #1 main panel upgrade |
No |
— |
0.95 |
no |
yes |
| Busbar #1 number of branch circuit breakers |
1 |
— |
0.82 |
no |
yes |
| Busbar #1 on line side of main service panel |
No |
— |
0.88 |
no |
yes |
| Busbar #1 panel type |
Main Service Panel |
— |
0.90 |
no |
yes |
| Busbar #1 rating (Amps) |
200 |
— |
0.95 |
no |
yes |
| Busbar #1 subject to backfeed |
Yes |
— |
0.85 |
no |
yes |
| Busbar feeder interconnection compliance method |
120% rule |
— |
0.88 |
no |
yes |
| Busbar feeder max THWN-2 conductors in raceway |
3 |
— |
0.90 |
no |
yes |
| Busbar feeder OCPD rating (Amps) |
70 |
— |
0.88 |
no |
yes |
| Busbar feeder wire gauge (AWG) |
4 |
— |
0.92 |
no |
yes |
| Combiner panel contains ESS |
No |
— |
0.50 |
no |
yes |
| Combiner panel has dedicated OCPD |
Yes |
— |
0.60 |
no |
yes |
| Combiner panel interconnection location |
New Subpanel |
— |
0.80 |
no |
yes |
| Current roof covering material |
Asphalt or composition shingles |
— |
0.95 |
no |
yes |
| ESS assembly weight (lbs) |
291 |
— |
0.92 |
no |
yes |
| ESS subject to vehicle damage (alternate) |
No |
— |
0.78 |
no |
yes |
| ESS unit charging from grid |
Yes |
— |
0.60 |
no |
yes |
| ESS unit has dedicated OCPD |
Yes |
— |
0.70 |
no |
yes |
| ESS unit installation location (architecture: Energy Storage System) |
Outdoor walls |
— |
0.70 |
no |
yes |
| ESS unit interconnection location |
New Subpanel |
— |
0.70 |
no |
yes |
| ESS unit is single unit with inverter |
Yes |
— |
0.90 |
no |
yes |
| ESS unit manufacturer (architecture: Energy Storage System) |
Tesla |
— |
0.95 |
no |
yes |
| ESS unit model (architecture: Energy Storage System) |
Powerwall 3 (1707000-11-J-DOM) |
— |
0.90 |
no |
yes |
| ESS unit OCPD rating (Amps) |
60 |
— |
0.85 |
no |
yes |
| ESS unit quantity (architecture: Energy Storage System) |
1 |
— |
0.95 |
no |
yes |
| ESS units have separation less than 3 feet (alternate) |
No |
— |
0.88 |
no |
yes |
| Flush mount or tilt-up |
Flush mount |
— |
0.90 |
no |
yes |
| Home has sprinkler systems |
No |
— |
0.45 |
no |
yes |
| Homeowner Full Name |
Teresa Ramirez |
— |
0.98 |
no |
yes |
| Inverter 1 interconnection location |
New Subpanel |
— |
0.80 |
no |
yes |
| Inverter 1 Manufacturer |
Tesla |
— |
0.98 |
no |
yes |
| Inverter 1 Model Number |
1707000-11-J-DOM |
— |
0.95 |
no |
yes |
| Inverter 1 OCPD rating (Amps) |
60 |
— |
0.95 |
no |
yes |
| Inverter architecture type |
String Inverter with DC-DC Converters |
— |
0.75 |
no |
yes |
| Inverter output uses NM cable |
No |
— |
0.88 |
no |
yes |
| Main breaker derate applied |
No |
— |
0.85 |
no |
yes |
| Max DC PV Wire / USE-2 conductors in raceway (excl. EGC) |
4 |
— |
0.85 |
no |
yes |
| Max DC THWN-2 conductors in raceway (excl. EGC) |
4 |
— |
0.85 |
no |
yes |
| Maximum distance from module to roof (inches) |
7 |
— |
0.70 |
no |
yes |
| Maximum input DC open circuit voltage (Voc) of PV inverter |
600 |
— |
0.90 |
no |
yes |
| Maximum input DC short circuit current (Isc) of PV inverter |
19 |
— |
0.90 |
no |
yes |
| Maximum number of modules in a DC series string |
7 |
— |
0.92 |
no |
yes |
| Maximum OCPD rating allowed on Inverter 1 (Amps) |
60 |
— |
0.90 |
no |
yes |
| Maximum spacing between adjacent attachment points (inches) |
48 |
— |
0.90 |
no |
yes |
| Max microinverters per branch circuit |
18 |
— |
0.55 |
no |
yes |
| Microinverter module capacity (W) |
450 |
— |
0.72 |
no |
yes |
| Microinverters protected by 20A OCPD |
Yes |
— |
0.72 |
no |
yes |
| Microinverter total quantity |
18 |
— |
0.92 |
no |
yes |
| Module 1 Quantity |
13 |
— |
0.98 |
no |
yes |
| Module fire rating type |
2 |
— |
0.50 |
no |
yes |
| Module is bifacial |
No |
— |
0.85 |
no |
yes |
| Module Manufacturer |
Q Cells |
— |
0.95 |
no |
yes |
| Module Model Number |
Q.PEAK DUO BLK ML-G10.C+ 410 |
— |
0.95 |
no |
yes |
| Number of composite shingle layers |
1 |
— |
0.50 |
no |
yes |
| OCPD protecting busbar #1 rating (Amps) |
70 |
— |
0.95 |
no |
yes |
| Project Address |
248 Mount Arbor St, McFarland, CA 93250 |
— |
0.95 |
no |
yes |
| Project valuation (USD) |
43296 |
— |
0.85 |
no |
yes |
| PV system weight (lbs/sq ft) |
4.0 |
— |
0.50 |
no |
yes |
| Racking System Manufacturer |
Unirac |
— |
0.95 |
no |
yes |
| Racking System Model Number |
NXT UMOUNT |
— |
0.95 |
no |
yes |
| Rafter has ceiling joists |
No |
— |
0.72 |
no |
yes |
| Rafter largest span (feet) |
24.0 |
— |
0.40 |
no |
yes |
| Rafter size (nominal) |
2x4 |
— |
0.95 |
no |
yes |
| Rafter spacing (inches) |
24 |
— |
0.95 |
no |
yes |
| Rafter type |
Engineered truss |
— |
0.90 |
no |
yes |
| Rapid Shutdown compliance method inside array |
Module-level shutdown (MLPE/MCI) |
— |
0.95 |
no |
yes |
| Rapid Shutdown Device Manufacturer |
Tesla |
— |
0.98 |
no |
yes |
| Rapid Shutdown Device Model Number |
MCI-2S |
— |
0.95 |
no |
yes |
| Rapid Shutdown Device Quantity |
5 |
— |
0.95 |
no |
yes |
| Roof framing type |
Truss |
— |
0.90 |
no |
yes |
| Roof has flat plane |
No |
— |
0.85 |
no |
yes |
| Roof penetration sealant method name and description |
Unirac Stronghold Butyl attachment with pre-applied butyl pad |
— |
0.85 |
no |
yes |
| Roof pitch |
4/12 |
— |
0.70 |
no |
yes |
| Storage architecture |
Energy Storage System |
— |
0.90 |
no |
yes |
| Supply side connection per NEC 705.12(A) |
No |
— |
0.85 |
no |
yes |
| Total roof area (sq ft) |
1884 |
— |
0.85 |
no |
yes |
| Utility available fault current greater than 10 kA at service |
No |
— |
0.60 |
no |
yes |
| Utility company name |
Southern California Edison |
— |
0.90 |
no |
yes |
| Utility service feed rating (Amps) |
200 |
— |
0.95 |
no |
yes |
| Whole home backup |
Yes |
— |
0.95 |
no |
yes |