| Attachment points staggered |
Yes |
— |
0.95 |
no |
yes |
| Busbar #1 already present on site |
Yes |
— |
0.90 |
no |
yes |
| Busbar #1 rating (Amps) |
100 |
— |
0.95 |
no |
yes |
| Busbar #1 subject to backfeed |
Yes |
— |
0.85 |
no |
yes |
| Current roof covering material |
Asphalt or composition shingles |
— |
0.99 |
no |
yes |
| Each ESS unit has dedicated OCPD |
Yes |
— |
0.90 |
no |
yes |
| ESS assembly weight (lbs) |
251 |
— |
0.60 |
no |
yes |
| ESS center of mass less than 4 feet from floor |
Yes |
— |
0.70 |
no |
yes |
| ESS in sleeping rooms or closets opening to sleeping rooms |
No |
— |
0.80 |
no |
yes |
| ESS installation location |
Outdoor walls |
— |
0.65 |
no |
yes |
| ESS location subject to vehicle damage |
No |
— |
0.65 |
no |
yes |
| ESS Model 1 includes DC-coupled expansion unit |
No |
— |
0.75 |
no |
yes |
| ESS Model 1 Manufacturer |
Tesla |
— |
0.99 |
no |
yes |
| ESS Model 1 Number |
1707000-XX-Y |
— |
0.95 |
no |
yes |
| ESS Model 1 Quantity |
1 |
— |
0.99 |
no |
yes |
| ESS positively attached to building per manufacturer |
Yes |
— |
0.85 |
no |
yes |
| ESS + PV Inverter certified as single unit (no field wiring) |
No |
— |
0.80 |
no |
yes |
| Flush mount or tilt-up |
Flush mount |
— |
0.90 |
no |
yes |
| Home has sprinkler systems |
No |
— |
0.99 |
no |
yes |
| Homeowner Full Name |
Benjamin Mandeville |
— |
0.99 |
no |
yes |
| Inverter 1 interconnection location |
Main Service Panel |
— |
0.90 |
no |
yes |
| Inverter 1 Manufacturer |
Enphase |
— |
0.99 |
no |
yes |
| Inverter 1 Model Number |
IQ8HC-72-M-DOM-US |
— |
0.99 |
no |
yes |
| Inverter 1 OCPD rating (Amps) |
30 |
— |
0.90 |
no |
yes |
| Inverter 1 power setting (kW) |
4.94 |
— |
0.90 |
no |
yes |
| Inverter architecture type |
Microinverters |
— |
0.99 |
no |
yes |
| Max DC PV Wire / USE-2 conductors in raceway (excl. EGC) |
2 |
— |
0.70 |
no |
yes |
| Max DC THWN-2 conductors in raceway (excl. EGC) |
2 |
— |
0.65 |
no |
yes |
| Maximum distance from module to roof (inches) |
6 |
— |
0.90 |
no |
yes |
| Maximum input DC open circuit voltage (Voc) of PV inverter |
60 |
— |
0.99 |
no |
yes |
| Maximum input DC short circuit current (Isc) of PV inverter |
25 |
— |
0.99 |
no |
yes |
| Maximum number of modules in a DC series string |
1 |
— |
0.95 |
no |
yes |
| Maximum OCPD rating allowed on Inverter 1 (Amps) |
20 |
— |
0.85 |
no |
yes |
| Maximum spacing between adjacent attachment points (inches) |
48 |
— |
0.99 |
no |
yes |
| Module 1 Quantity |
13 |
— |
0.99 |
no |
yes |
| Module fire rating type |
1 |
— |
0.75 |
no |
yes |
| Module is bifacial |
No |
— |
0.80 |
no |
yes |
| Module Manufacturer |
HANWHA Q CELLS |
— |
0.95 |
no |
yes |
| Module Model Number |
Q.PEAK DUO BLK ML-G10.C+ 410 |
— |
0.99 |
no |
yes |
| Number of busbars |
1 |
— |
0.85 |
no |
yes |
| Number of composite shingle layers |
1 |
— |
0.60 |
no |
yes |
| Number of distinct ESS models |
1 |
— |
0.99 |
no |
yes |
| OCPD protecting busbar #1 rating (Amps) |
100 |
— |
0.90 |
no |
yes |
| Project Address |
2135 Mission Boulevard, Santa Rosa, CA 95409 |
— |
0.99 |
no |
yes |
| PV system weight (lbs/sq ft) |
4.0 |
— |
0.40 |
no |
yes |
| Racking System Manufacturer |
SnapNRack |
— |
0.99 |
no |
yes |
| Racking System Model Number |
UR-45 Rail (232-10095-USA) |
— |
0.95 |
no |
yes |
| Rapid Shutdown compliance method inside array |
Module-level power electronics (MLPE) — Enphase IQ8HC microinverters listed as rapid shutdown equipment per UL 1741 |
— |
0.90 |
no |
yes |
| Rapid Shutdown Device Manufacturer |
Enphase |
— |
0.85 |
no |
yes |
| Rapid Shutdown Device Model Number |
IQ8HC-72-M-DOM-US |
— |
0.80 |
no |
yes |
| Roof penetration sealant method name and description |
Sealed penetration with manufacturer-specified sealant via SnapNRack UltraFoot rafter attachment; rooftop penetrations completed and sealed per code by licensed contractor |
— |
0.80 |
no |
yes |
| Roof pitch |
4/12 |
— |
0.80 |
no |
yes |
| Separation between ESS units less than 3 feet |
No |
— |
0.70 |
no |
yes |
| Smoke/heat alarm present at ESS location |
No |
— |
0.50 |
no |
yes |
| Supply side connection per NEC 705.12(A) |
No |
— |
0.85 |
no |
yes |
| THWN-2 conductors in PV inverter AC output circuit raceway (excl. EGC) |
2 |
— |
0.75 |
no |
yes |
| Total roof area (sq ft) |
2535 |
— |
0.99 |
no |
yes |
| Using Power Control System to curtail Inverter 1 |
No |
— |
0.75 |
no |
yes |
| Utility available fault current greater than 10 kA at service |
No |
— |
0.65 |
no |
yes |
| Utility service feed rating (Amps) |
100 |
— |
0.99 |
no |
yes |