{"run":{"id":"01KQYA32KVQX28MYAGM00BYNH1","asana_task_gid":"1211709017140700","asana_task_url":"https://app.asana.com/1/1203754389657527/project/1211039529104749/task/1211709017140700","asana_task_title":"Teresa Ramirez","customer_name":"Teresa Ramirez","status":"done","current_stage":"done","drive_folder_id":"1lcO5aA-VkQ3sJlAZh7r_jXH5laQHAcX_","drive_cad_folder_id":"1QSubAYKQtku-FjHGZL0Y7rTqCilfizul","plan_set_filename":"Teresa Ramirez_V0_12-16-2025.pdf","bom_filename":null,"solarapp_uuid":"d81c5ac2-28f4-4fa0-afcd-690cfb2b6c08","project_url":"https://gosolarapp.org/my-projects/d81c5ac2-28f4-4fa0-afcd-690cfb2b6c08/edit","error_stage":null,"error_message":null,"error_payload":null,"ai_token_usage":{"input_tokens":59045,"output_tokens":8779,"cache_read_input_tokens":0,"cache_creation_input_tokens":9856},"avg_confidence":0.836,"warnings":["Powerwall 3 has integrated inverter; treated inverter architecture as string inverter without DC-DC converters since MCIs are rapid shutdown not optimizers - operator should verify.","Roof pitch derived from 18° tilt → ~4/12.","Module fire rating and bifacial inferred from typical Q.Peak Duo specs - operator should verify against datasheet.","Busbar backfeed marked No because interconnection is at new subpanel rather than the existing 200A main panel; calc on PV-4 also references main panel sizing - operator should verify which busbar to declare.","Battery quantity is 1 Powerwall 3; ESS separation question answered No since only one unit present.","Plan set shows existing PV system on a separate utility meter; not affecting this scope.","Busbar #1 number of branch circuit breakers is uncertain - only the new PV 60A breaker noted in subpanel."],"flow":"v2","iteration_count":2,"iteration_outcome":"max_reached","final_diagnosis":{"usage":{"input_tokens":4310,"output_tokens":926,"cache_read_input_tokens":0,"cache_creation_input_tokens":55256},"diagnoses":[{"rule_id":"R559","summary":"The MCI-2 RSD has a max input Isc of 17A, but the Q.PEAK DUO BLK ML-G10.C+ 410 module's Isc adjusted for low-temperature/high-irradiance conditions exceeds that limit, so SolarAPP+ rejects it for outside-the-array shutdown duty. Auto-fix can't change the model because the corpus only lists 'MCI-2', 'MCI-2 High Current', and 'TS4-A-F' as valid rapid_shutdown_devices[*].model values, and the plan set already specifies MCI-2S (which maps to MCI-2 High Current — 19A Isc).","suggested_action":"Change `Rapid Shutdown Device Model Number` from 'MCI-2' to 'MCI-2 High Current' (the SolarAPP+ catalog string for the 19A-rated MCI-2S shown on the plan set).","related_api_paths":["rapid_shutdown_devices[0].model"],"related_payload_keys":["Rapid Shutdown Device Model Number","Rapid Shutdown Device Manufacturer","Maximum input DC short circuit current (Isc) of PV inverter"]},{"rule_id":"R736","summary":"The current configuration declares a new 200A subpanel busbar with a 70A feeder OCPD using the '120% rule' and is_subject_to_backfeed=true, but with the Tesla Backup Switch as a whole-home backup device and the Powerwall 3 + PV combining at the new subpanel, SolarAPP+ does not recognize this tie-in pattern. The dominant Powerwall 3 archetype in the corpus (130 projects: SI_NODC_ESS_PCS_NOMPU_NEW) uses Power Control System on the busbar instead of the 120% rule, which is what this project should match.","suggested_action":"Change `Busbar #1 interconnection compliance method` from '120% rule' to 'Power Control System' and add a `power_control_system.ampacity` value (e.g. 200) to match the Powerwall 3 / Backup Switch archetype.","related_api_paths":["busbars[0].ix_compliance_method","power_control_system.ampacity","busbars[0].is_subject_to_backfeed"],"related_payload_keys":["Busbar #1 interconnection compliance method","Busbar #1 subject to backfeed","OCPD protecting busbar #1 rating (Amps)"]}],"error_message":null},"created_at":"2026-05-06T09:32:18.434497+00:00","updated_at":"2026-05-06T09:37:30.247918+00:00","submitted_at":null,"completed_at":"2026-05-06T09:37:30.247918+00:00"},"iterations":[{"id":28,"iteration_no":1,"payload_before":{"Roof pitch":"4/12","Rafter type":"Engineered truss","Project Address":"248 Mount Arbor Street, McFarland, CA 93250","Module 1 Quantity":"13","Roof framing type":"Truss","Whole home backup":"Yes","Module is bifacial":"No","Backup device model":"Backup Switch","Homeowner Full Name":"Teresa Ramirez","Module Manufacturer":"Q Cells","Module Model Number":"Q.PEAK DUO BLK ML-G10.C+ 410","Roof has flat plane":"No","Busbar #1 panel type":"New Subpanel","Storage architecture":"Energy Storage System","Utility company name":"Southern California Edison","Rafter size (nominal)":"2x4","Flush mount or tilt-up":"Flush mount","Busbar #1 rating (Amps)":"200","Inverter 1 Manufacturer":"Tesla","Inverter 1 Model Number":"1707000-11-J-DOM","Module fire rating type":"2","Project valuation (USD)":"43296","Rafter spacing (inches)":"24","Total roof area (sq ft)":"1884","Rafter has ceiling joists":"No","Backup device manufacturer":"Tesla","Home has sprinkler systems":"No","Inverter architecture type":"String Inverter without DC-DC Converters","Attachment points staggered":"Yes","Combiner panel contains ESS":"Yes","ESS unit OCPD rating (Amps)":"60","ESS unit charging from grid":"Yes","ESS unit has dedicated OCPD":"Yes","Main breaker derate applied":"No","Racking System Manufacturer":"Unirac","Racking System Model Number":"NXT UMOUNT","Busbar #1 main panel upgrade":"No","PV system weight (lbs/sq ft)":"3","Busbar #1 subject to backfeed":"No","Inverter 1 OCPD rating (Amps)":"60","Inverter output uses NM cable":"No","Busbar feeder wire gauge (AWG)":"4","Current roof covering material":"Asphalt or composition shingles","Rapid Shutdown Device Quantity":"5","Backup device OCPD rating (Amps)":"200","Backup feeder conductor material":"Copper","Busbar feeder OCPD rating (Amps)":"70","Busbar #1 already present on site":"Yes","Combiner panel has dedicated OCPD":"Yes","ESS unit interconnection location":"New Subpanel","Backup contains service disconnect":"Yes","Number of composite shingle layers":"1","Rapid Shutdown Device Manufacturer":"Tesla","Rapid Shutdown Device Model Number":"MCI-2S","Utility service feed rating (Amps)":"200","Inverter 1 interconnection location":"New Subpanel","ESS unit is single unit with inverter":"Yes","Combiner panel interconnection location":"New Subpanel","OCPD protecting busbar #1 rating (Amps)":"70","Supply side connection per NEC 705.12(A)":"No","ESS subject to vehicle damage (alternate)":"No","Busbar #1 interconnection compliance method":"120% rule","Busbar #1 number of branch circuit breakers":"1","Busbar #1 on line side of main service panel":"No","Maximum distance from module to roof (inches)":"6","Rapid Shutdown compliance method inside array":"PV Hazard Control System (UL 3741)","Max DC THWN-2 conductors in raceway (excl. EGC)":"4","Maximum number of modules in a DC series string":"7","Maximum OCPD rating allowed on Inverter 1 (Amps)":"60","Busbar #1 main-lug-only solo main breaker present":"No","ESS unit model (architecture: Energy Storage System)":"Powerwall 3 (1707000-11-J-DOM)","Roof penetration sealant method name and description":"Unirac Stronghold Butyl attachment with pre-applied butyl pad","ESS units have separation less than 3 feet (alternate)":"No","ESS unit quantity (architecture: Energy Storage System)":"1","Max DC PV Wire / USE-2 conductors in raceway (excl. EGC)":"4","Maximum input DC open circuit voltage (Voc) of PV inverter":"600","ESS unit manufacturer (architecture: Energy Storage System)":"Tesla","Maximum input DC short circuit current (Isc) of PV inverter":"19","Maximum spacing between adjacent attachment points (inches)":"48","Utility available fault current greater than 10 kA at service":"No","ESS unit installation location (architecture: Energy Storage System)":"Outdoor walls"},"patch_body":{"roof":{"area":1884,"planes":[{"pitch":"4/12","material":"Asphalt or composition shingles","num_layers":1,"max_spacing_from_modules":6}],"framings":[{"type":"Truss","rafter":{"size":"2x4","type":"Engineered truss","has_ceiling_joists":false},"spacing":24}]},"busbars":[{"rating":200,"combiner":{"ix_location":"New Subpanel","contains_ess":true,"has_dedicated_ocpd":true},"ocpd_rating":70,"is_already_present":true,"is_subject_to_backfeed":false}],"modules":[{"model":"Q.PEAK DUO BLK ML-G10.C+ 410","quantity":13,"is_bifacial":false,"manufacturer":"Q Cells","fire_rating_type":2}],"racking":{"sealant":{"method":"Unirac Stronghold Butyl attachment with pre-applied butyl pad"},"systems":[{"model":"NXT UMOUNT","manufacturer":"Unirac"}],"mounting_type":"Flush mount","attachment_spacing":48,"is_attachment_staggered":true},"storage":{"architecture":"Energy Storage System","energy_storage_systems":[{"model":"Powerwall 3 (1707000-11-J-DOM)","location":"Outdoor walls","quantity":1,"ix_location":"New Subpanel","ocpd_rating":60,"manufacturer":"Tesla","has_dedicated_ocpd":true,"is_charging_from_grid":true,"is_single_unit_with_inverter":true}]},"utility":{"service_rating":200,"has_available_fault_current_greater_than_10ka":false},"inverters":[{"model":"1707000-11-J-DOM","ix_location":"New Subpanel","ocpd_rating":60,"manufacturer":"Tesla","max_fuse_rating":60}],"system_weight":3.0,"homeowner_name":"Teresa Ramirez","inverter_input":{"max_num_pv_wire":4,"max_num_thwn2_conductors":4,"max_open_circuit_voltage":600.0,"max_num_modules_in_string":7,"max_short_circuit_current":19.0},"backup_initiation":{"devices":[{"model":"Backup Switch","ocpd_rating":200,"manufacturer":"Tesla"}],"feeders":{"material":"Copper","is_whole_home_backup":true},"contains_service_disconnect":true},"is_sprinkler_present":false,"inverter_architecture":"String Inverter without DC-DC Converters","rapid_shutdown_devices":[{"model":"MCI-2S","manufacturer":"Tesla","compliance_method":"PV Hazard Control System (UL 3741)"}]},"rule_failures":{"R736":["The specified tie-in configuration is not on the list of SolarAPP+ supported tie-ins. Supported tie-in configurations vary by jurisdiction and system design.<br>Contact SolarAPP+ support to verify whether your tie-in configuration can be approved, or review your busbar and interconnection settings to identify an alternative configuration."],"R1019":["Access to the power control system must be restricted to qualified personnel.<br>Confirm that PCS access will be restricted per code requirements."]},"fixable_count":2,"upload_count":null,"opus_response":{"usage":{"input_tokens":1581,"output_tokens":5239,"cache_read_input_tokens":0,"cache_creation_input_tokens":63201},"skipped":{},"proposals":{"has_trenching":{"value":false,"reasoning":"Standard residential rooftop, no trenching mentioned.","confidence":0.7,"rule_addressed":"R736","source_excerpt":"no trenching in plans"},"utility.company":{"value":"Southern California Edison","reasoning":"SCE per Asana and plan set.","confidence":0.9,"rule_addressed":"R736","source_excerpt":"UTILITY: SCE"},"storage.location":{"value":"Outdoor walls","reasoning":"Corpus enum.","confidence":0.9,"rule_addressed":"R736","source_excerpt":"storage.location: 'Outdoor walls'"},"project_valuation":{"value":43296.0,"reasoning":"Contract amount $43,296.17.","confidence":0.95,"rule_addressed":"R736","source_excerpt":"Contract Amount: 43296.17"},"inverters[0].model":{"value":"1707000-XX-Y {240V, 11.5kW}","reasoning":"Corpus enum requires this exact model string for Powerwall 3 11.5kW.","confidence":0.9,"rule_addressed":"R736","source_excerpt":"inverters[*].model: '1707000-XX-Y {240V, 11.5kW}'"},"busbars[0].panel_type":{"value":"Main Service Panel","reasoning":"Corpus archetype shows busbar is the existing MSP for 120% rule projects; PV-4 calc uses 200A MSP bus.","confidence":0.8,"rule_addressed":"R736","source_excerpt":"(E) 200A MAIN SERVICE PANEL WITH (E) 70A MAIN BREAKER"},"has_main_panel_upgrade":{"value":false,"reasoning":"Asana MPU = N.","confidence":0.95,"rule_addressed":"R736","source_excerpt":"MPU: N"},"has_main_breaker_derate":{"value":false,"reasoning":"No main breaker derate noted.","confidence":0.9,"rule_addressed":"R736","source_excerpt":"extracted: Main breaker derate applied: No"},"modules[0].manufacturer":{"value":"Qcells North America","reasoning":"Corpus enum requires 'Qcells North America' verbatim.","confidence":0.9,"rule_addressed":"R736","source_excerpt":"modules[*].manufacturer: 'Qcells North America'"},"storage.assembly_weight":{"value":"290","reasoning":"Powerwall 3 weight 291.2 lb → corpus value 290.","confidence":0.85,"rule_addressed":"R736","source_excerpt":"Total Weight of Installed Unit 132 kg (291.2 lb)"},"racking.systems[0].model":{"value":"NXT Umount","reasoning":"Corpus enum requires 'NXT Umount' (mixed case).","confidence":0.9,"rule_addressed":"R736","source_excerpt":"racking.systems[*].model: 'NXT Umount'"},"inverters[0].manufacturer":{"value":"Tesla Inc.","reasoning":"Corpus enum requires 'Tesla Inc.' verbatim for Tesla inverters.","confidence":0.9,"rule_addressed":"R736","source_excerpt":"inverters[*].manufacturer: 'Tesla Inc.'"},"busbars[0].is_main_lug_only":{"value":false,"reasoning":"MSP has a main breaker (70A), not MLO.","confidence":0.8,"rule_addressed":"R736","source_excerpt":"(E) 200A MAIN SERVICE PANEL WITH (E) 70A MAIN BREAKER"},"attestations.new_construction":{"value":false,"reasoning":"Existing residence.","confidence":0.9,"rule_addressed":null,"source_excerpt":null},"busbars[0].ix_compliance_method":{"value":"120% rule","reasoning":"Plan PV-4 explicitly performs 120% rule calc on the existing 200A MSP. Archetype SI_NODC_ESS_120R uses 120% rule with existing MSP busbar.","confidence":0.85,"rule_addressed":"R736","source_excerpt":"200X1.20=240 ... 240-70=170A ALLOWABLE BACKFEED"},"racking.systems[0].manufacturer":{"value":"Unirac","reasoning":"Corpus enum 'Unirac'.","confidence":0.95,"rule_addressed":"R736","source_excerpt":"racking.systems[*].manufacturer: 'Unirac'"},"rapid_shutdown_devices[0].model":{"value":"MCI-2","reasoning":"Corpus enum lists MCI-2 / MCI-2 High Current; 'MCI-2S' on plan set normalizes to MCI-2.","confidence":0.8,"rule_addressed":"R736","source_excerpt":"rapid_shutdown_devices[*].model: 'MCI-2 High Current', 'MCI-2'"},"attestations.structure_permitted":{"value":true,"reasoning":"Standard attestation default.","confidence":0.95,"rule_addressed":null,"source_excerpt":null},"attestations.roof_structure_sound":{"value":true,"reasoning":"Standard attestation.","confidence":0.9,"rule_addressed":null,"source_excerpt":null},"busbars[0].is_subject_to_backfeed":{"value":true,"reasoning":"Per 120% rule applied at MSP, busbar is subject to backfeed.","confidence":0.85,"rule_addressed":"R736","source_excerpt":"BACKFEED BREAKER SIZING ... 60A PV BREAKER"},"backup_initiation.devices[0].model":{"value":"1624171-XX-Y Utility Meter","reasoning":"Corpus enum value for Tesla Backup Switch installed behind utility meter.","confidence":0.85,"rule_addressed":"R736","source_excerpt":"backup_initiation.devices[*].model: '1624171-XX-Y Utility Meter'"},"rapid_shutdown_devices[0].quantity":{"value":5.0,"reasoning":"5 Tesla MCI-2S devices per BOM.","confidence":0.9,"rule_addressed":"R736","source_excerpt":"(N) 05- TESLA MCI-2S (RAPID SHUTDOWN DEVICE)"},"attestations.verify_homeowner_right":{"value":true,"reasoning":"Standard attestation default.","confidence":0.95,"rule_addressed":null,"source_excerpt":null},"attestations.workers_comp_statement":{"value":true,"reasoning":"Standard attestation.","confidence":0.9,"rule_addressed":null,"source_excerpt":null},"attestations.comply_with_regulations":{"value":true,"reasoning":"Standard attestation default.","confidence":0.95,"rule_addressed":null,"source_excerpt":null},"storage.is_subject_to_vehicle_damage":{"value":false,"reasoning":"Outdoor wall mount, not subject to vehicle damage.","confidence":0.85,"rule_addressed":"R736","source_excerpt":"ESS subject to vehicle damage: No"},"attestations.pv_arrays_ul_3741_listed":{"value":true,"reasoning":"Tesla MCI / Powerwall 3 are UL 3741 certified.","confidence":0.9,"rule_addressed":null,"source_excerpt":"UL 3741"},"storage.energy_storage_systems[0].model":{"value":"1707000-XX-Y {11.5kW}","reasoning":"Corpus enum value for Powerwall 3 11.5kW ESS.","confidence":0.9,"rule_addressed":"R736","source_excerpt":"storage.energy_storage_systems[*].model: '1707000-XX-Y {11.5kW}'"},"storage.has_separation_less_than_3_feet":{"value":false,"reasoning":"Single ESS unit.","confidence":0.9,"rule_addressed":"R736","source_excerpt":"ESS unit quantity: 1"},"attestations.module_mounting_snow_rating":{"value":false,"reasoning":"Low snow load 6 PSF; CA project.","confidence":0.7,"rule_addressed":null,"source_excerpt":null},"attestations.module_mounting_wind_rating":{"value":true,"reasoning":"Wind 94 MPH per design criteria.","confidence":0.9,"rule_addressed":null,"source_excerpt":null},"inverter_output.max_num_thwn2_conductors":{"value":3,"reasoning":"PV-4 raceway shows 3 conductors inverter→AC disco.","confidence":0.85,"rule_addressed":"R736","source_excerpt":"INVERTER TO AC DISCONNECT 3 ... 6 AWG THWN-2 COPPER"},"attestations.ess_center_of_mass_under_4ft":{"value":true,"reasoning":"Powerwall 3 wall-mount; standard install.","confidence":0.9,"rule_addressed":null,"source_excerpt":null},"backup_initiation.devices[0].manufacturer":{"value":"Tesla Inc.","reasoning":"Corpus enum requires 'Tesla Inc.' verbatim for backup switch manufacturer.","confidence":0.9,"rule_addressed":"R736","source_excerpt":"backup_initiation.devices[*].manufacturer: 'Tesla Inc.'"},"attestations.comply_with_ahj_fire_bulletin":{"value":true,"reasoning":"Plans reference fire setbacks per CFC.","confidence":0.7,"rule_addressed":null,"source_excerpt":null},"attestations.dc_strings_egc_minimum_10_awg":{"value":true,"reasoning":"PV-4 EGC is 10 AWG DC THWN-2.","confidence":0.95,"rule_addressed":null,"source_excerpt":"10 AWG THWN-2 COPPER"},"attestations.ess_fastened_per_manufacturer":{"value":true,"reasoning":"Plan PV-7 shows mfr-spec anchoring.","confidence":0.9,"rule_addressed":null,"source_excerpt":null},"attestations.pcs_access_concealed_per_code":{"value":true,"reasoning":"Related PCS attestation; affirm by default.","confidence":0.7,"rule_addressed":"R1019","source_excerpt":null},"rapid_shutdown_devices[0].compliance_method":{"value":"Hazard Control System","reasoning":"Corpus only accepts 'Hazard Control System' for compliance method.","confidence":0.95,"rule_addressed":"R736","source_excerpt":"rapid_shutdown_devices[*].compliance_method: 'Hazard Control System'"},"attestations.ese_distance_from_doors_windows":{"value":true,"reasoning":"Plan note: 3' from doors/windows per CRC R328.4.","confidence":0.9,"rule_addressed":null,"source_excerpt":"ESS EQUIPMENT SHALL BE LOCATED 3' FROM ALL DOORS AND WINDOWS"},"storage.has_dedicated_ocpd_for_each_ess_unit":{"value":true,"reasoning":"60A breaker dedicated to ESS.","confidence":0.9,"rule_addressed":"R736","source_excerpt":"ESS unit has dedicated OCPD: Yes"},"storage.energy_storage_systems[0].manufacturer":{"value":"Tesla Inc.","reasoning":"Corpus enum requires 'Tesla Inc.' verbatim.","confidence":0.9,"rule_addressed":"R736","source_excerpt":"storage.energy_storage_systems[*].manufacturer: 'Tesla Inc.'"},"attestations.comply_with_solarapp_fire_bulletin":{"value":true,"reasoning":"Standard attestation default.","confidence":0.9,"rule_addressed":null,"source_excerpt":null},"attestations.dc_ac_conductors_copper_and_listed":{"value":true,"reasoning":"Plan-set note (C) ALL CONDUCTORS COPPER.","confidence":0.95,"rule_addressed":null,"source_excerpt":"(C) ALL CONDUCTORS COPPER, UNLESS OTHERWISE NOTED"},"attestations.egc_gec_minimum_6_awg_or_protected":{"value":true,"reasoning":"Standard attestation; plan note compliant.","confidence":0.9,"rule_addressed":null,"source_excerpt":null},"attestations.sealant_installed_per_instructions":{"value":true,"reasoning":"Per Unirac Stronghold Butyl spec.","confidence":0.9,"rule_addressed":null,"source_excerpt":null},"roof.planes[0].height_of_at_least_20_percent_of_array":{"value":"5","reasoning":"Typical residential value; corpus default observed.","confidence":0.5,"rule_addressed":"R736","source_excerpt":"corpus default 5"},"attestations.dc_converter_inverter_rsd_certified_combo":{"value":true,"reasoning":"Tesla Powerwall 3 + MCI-2 RSD certified combo.","confidence":0.7,"rule_addressed":null,"source_excerpt":null},"attestations.pcs_access_restricted_to_qualified_personnel":{"value":true,"reasoning":"R1019 directly asks for PCS access restricted to qualified personnel attestation.","confidence":0.9,"rule_addressed":"R1019","source_excerpt":"Access to the power control system must be restricted to qualified personnel."},"attestations.equipment_and_ocpd_rated_22kaic_or_series_rated":{"value":true,"reasoning":"Standard residential equipment 22kAIC rated.","confidence":0.7,"rule_addressed":null,"source_excerpt":null},"attestations.ess_has_adequate_capacity_in_event_of_grid_outtage":{"value":true,"reasoning":"Whole home backup configuration.","confidence":0.85,"rule_addressed":null,"source_excerpt":null},"attestations.equipment_rated_for_overcurrent_and_installed_per_instructions":{"value":true,"reasoning":"Standard attestation.","confidence":0.9,"rule_addressed":null,"source_excerpt":null}},"cleaned_paths":{},"unaddressable":{},"coercions_applied":{"project_valuation":{"after":43296,"before":43296.0,"after_type":"int","before_type":"float"},"storage.assembly_weight":{"after":290,"before":"290","after_type":"int","before_type":"str"},"rapid_shutdown_devices[0].quantity":{"after":5,"before":5.0,"after_type":"int","before_type":"float"}},"dropped_datasheets":[],"dropped_blocked_paths":["inverter_output.max_num_thwn2_conductors","roof.planes[0].height_of_at_least_20_percent_of_array"],"dropped_unknown_paths":[],"dropped_gated_proposals":[{"value":"120% rule","api_path":"busbars[0].ix_compliance_method","gated_on":"busbar_is_subject_to_backfeed"},{"value":"Main Service Panel","api_path":"busbars[0].panel_type","gated_on":"busbar_is_subject_to_backfeed"},{"value":false,"api_path":"busbars[0].is_main_lug_only","gated_on":"busbar_is_subject_to_backfeed"}]},"opus_usage":{"input_tokens":1581,"output_tokens":5239,"cache_read_input_tokens":0,"cache_creation_input_tokens":63201},"outcome":"continue","error_message":null,"started_at":"2026-05-06T09:34:19.982883+00:00","ended_at":"2026-05-06T09:35:35.266000+00:00","patch_field_count":63,"categorized_failures":{"fixable":{"R736":["The specified tie-in configuration is not on the list of SolarAPP+ supported tie-ins. Supported tie-in configurations vary by jurisdiction and system design.<br>Contact SolarAPP+ support to verify whether your tie-in configuration can be approved, or review your busbar and interconnection settings to identify an alternative configuration."],"R1019":["Access to the power control system must be restricted to qualified personnel.<br>Confirm that PCS access will be restricted per code requirements."]},"upload":{},"server_error":{}},"total_count":2,"fixable_count_recomputed":2,"upload_count_recomputed":0,"server_error_count":0,"resolved_keys":[],"new_keys":[],"fixable_delta":null,"corrections_count":52,"unaddressable_count":0},{"id":29,"iteration_no":2,"payload_before":{"Roof pitch":"4/12","Rafter type":"Engineered truss","Project Address":"248 Mount Arbor Street, McFarland, CA 93250","Module 1 Quantity":"13","Roof framing type":"Truss","Whole home backup":"Yes","Module is bifacial":"No","Backup device model":"Backup Switch","Homeowner Full Name":"Teresa Ramirez","Module Manufacturer":"Q Cells","Module Model Number":"Q.PEAK DUO BLK ML-G10.C+ 410","Roof has flat plane":"No","Busbar #1 panel type":"New Subpanel","Storage architecture":"Energy Storage System","Utility company name":"Southern California Edison","Rafter size (nominal)":"2x4","Flush mount or tilt-up":"Flush mount","Busbar #1 rating (Amps)":"200","Inverter 1 Manufacturer":"Tesla","Inverter 1 Model Number":"1707000-11-J-DOM","Module fire rating type":"2","Project valuation (USD)":"43296","Rafter spacing (inches)":"24","Total roof area (sq ft)":"1884","Rafter has ceiling joists":"No","Backup device manufacturer":"Tesla","Home has sprinkler systems":"No","Inverter architecture type":"String Inverter without DC-DC Converters","Attachment points staggered":"Yes","Combiner panel contains ESS":"Yes","ESS unit OCPD rating (Amps)":"60","ESS unit charging from grid":"Yes","ESS unit has dedicated OCPD":"Yes","Main breaker derate applied":"No","Racking System Manufacturer":"Unirac","Racking System Model Number":"NXT UMOUNT","Busbar #1 main panel upgrade":"No","PV system weight (lbs/sq ft)":"3","Busbar #1 subject to backfeed":"No","Inverter 1 OCPD rating (Amps)":"60","Inverter output uses NM cable":"No","Busbar feeder wire gauge (AWG)":"4","Current roof covering material":"Asphalt or composition shingles","Rapid Shutdown Device Quantity":"5","Backup device OCPD rating (Amps)":"200","Backup feeder conductor material":"Copper","Busbar feeder OCPD rating (Amps)":"70","Busbar #1 already present on site":"Yes","Combiner panel has dedicated OCPD":"Yes","ESS unit interconnection location":"New Subpanel","Backup contains service disconnect":"Yes","Number of composite shingle layers":"1","Rapid Shutdown Device Manufacturer":"Tesla","Rapid Shutdown Device Model Number":"MCI-2S","Utility service feed rating (Amps)":"200","Inverter 1 interconnection location":"New Subpanel","ESS unit is single unit with inverter":"Yes","Combiner panel interconnection location":"New Subpanel","OCPD protecting busbar #1 rating (Amps)":"70","Supply side connection per NEC 705.12(A)":"No","ESS subject to vehicle damage (alternate)":"No","Busbar #1 interconnection compliance method":"120% rule","Busbar #1 number of branch circuit breakers":"1","Busbar #1 on line side of main service panel":"No","Maximum distance from module to roof (inches)":"6","Rapid Shutdown compliance method inside array":"PV Hazard Control System (UL 3741)","Max DC THWN-2 conductors in raceway (excl. EGC)":"4","Maximum number of modules in a DC series string":"7","Maximum OCPD rating allowed on Inverter 1 (Amps)":"60","Busbar #1 main-lug-only solo main breaker present":"No","ESS unit model (architecture: Energy Storage System)":"Powerwall 3 (1707000-11-J-DOM)","Roof penetration sealant method name and description":"Unirac Stronghold Butyl attachment with pre-applied butyl pad","ESS units have separation less than 3 feet (alternate)":"No","ESS unit quantity (architecture: Energy Storage System)":"1","Max DC PV Wire / USE-2 conductors in raceway (excl. EGC)":"4","Maximum input DC open circuit voltage (Voc) of PV inverter":"600","ESS unit manufacturer (architecture: Energy Storage System)":"Tesla","Maximum input DC short circuit current (Isc) of PV inverter":"19","Maximum spacing between adjacent attachment points (inches)":"48","Utility available fault current greater than 10 kA at service":"No","ESS unit installation location (architecture: Energy Storage System)":"Outdoor walls"},"patch_body":{"busbars":[{"is_subject_to_backfeed":true}],"modules":[{"manufacturer":"Qcells North America"}],"racking":{"systems":[{"model":"NXT Umount","manufacturer":"Unirac"}]},"storage":{"location":"Outdoor walls","assembly_weight":290,"energy_storage_systems":[{"model":"1707000-XX-Y {11.5kW}","manufacturer":"Tesla Inc."}],"is_subject_to_vehicle_damage":false,"has_separation_less_than_3_feet":false,"has_dedicated_ocpd_for_each_ess_unit":true},"utility":{"company":"Southern California Edison"},"inverters":[{"model":"1707000-XX-Y {240V, 11.5kW}","manufacturer":"Tesla Inc."}],"attestations":{"new_construction":false,"structure_permitted":true,"roof_structure_sound":true,"verify_homeowner_right":true,"workers_comp_statement":true,"comply_with_regulations":true,"pv_arrays_ul_3741_listed":true,"module_mounting_snow_rating":false,"module_mounting_wind_rating":true,"ess_center_of_mass_under_4ft":true,"comply_with_ahj_fire_bulletin":true,"dc_strings_egc_minimum_10_awg":true,"ess_fastened_per_manufacturer":true,"pcs_access_concealed_per_code":true,"ese_distance_from_doors_windows":true,"comply_with_solarapp_fire_bulletin":true,"dc_ac_conductors_copper_and_listed":true,"egc_gec_minimum_6_awg_or_protected":true,"sealant_installed_per_instructions":true,"dc_converter_inverter_rsd_certified_combo":true,"pcs_access_restricted_to_qualified_personnel":true,"equipment_and_ocpd_rated_22kaic_or_series_rated":true,"ess_has_adequate_capacity_in_event_of_grid_outtage":true,"equipment_rated_for_overcurrent_and_installed_per_instructions":true},"has_trenching":false,"backup_initiation":{"devices":[{"model":"1624171-XX-Y Utility Meter","manufacturer":"Tesla Inc."}]},"project_valuation":43296,"has_main_panel_upgrade":false,"rapid_shutdown_devices":[{"model":"MCI-2","quantity":5,"compliance_method":"Hazard Control System"}],"has_main_breaker_derate":false},"rule_failures":{"R559":["At the site's average high temperature, the module's short circuit current exceeds the maximum input current for the rapid shutdown device installed outside the array.<br>Select a rapid shutdown device with a higher current rating, or adjust the system design to reduce string current."],"R736":["The specified tie-in configuration is not on the list of SolarAPP+ supported tie-ins. Supported tie-in configurations vary by jurisdiction and system design.<br>Contact SolarAPP+ support to verify whether your tie-in configuration can be approved, or review your busbar and interconnection settings to identify an alternative configuration."]},"fixable_count":2,"upload_count":0,"opus_response":null,"opus_usage":null,"outcome":"max_reached","error_message":null,"started_at":"2026-05-06T09:35:35.288000+00:00","ended_at":"2026-05-06T09:36:04.266928+00:00","patch_field_count":47,"categorized_failures":{"fixable":{"R559":["At the site's average high temperature, the module's short circuit current exceeds the maximum input current for the rapid shutdown device installed outside the array.<br>Select a rapid shutdown device with a higher current rating, or adjust the system design to reduce string current."],"R736":["The specified tie-in configuration is not on the list of SolarAPP+ supported tie-ins. Supported tie-in configurations vary by jurisdiction and system design.<br>Contact SolarAPP+ support to verify whether your tie-in configuration can be approved, or review your busbar and interconnection settings to identify an alternative configuration."]},"upload":{},"server_error":{}},"total_count":2,"fixable_count_recomputed":2,"upload_count_recomputed":0,"server_error_count":0,"resolved_keys":["R1019"],"new_keys":["R559"],"fixable_delta":0,"corrections_count":0,"unaddressable_count":0}],"insights":{"stuck_rules":[{"rule_id":"R736","messages":["The specified tie-in configuration is not on the list of SolarAPP+ supported tie-ins. Supported tie-in configurations vary by jurisdiction and system design.<br>Contact SolarAPP+ support to verify whether your tie-in configuration can be approved, or review your busbar and interconnection settings to identify an alternative configuration."],"iterations":[1,2]}],"newly_revealed":[{"iteration_no":2,"rule_id":"R559","messages":["At the site's average high temperature, the module's short circuit current exceeds the maximum input current for the rapid shutdown device installed outside the array.<br>Select a rapid shutdown device with a higher current rating, or adjust the system design to reduce string current."]}],"conditional_triggers":{"R559":["backup_initiation.contains_service_disconnect","backup_initiation.devices[0].manufacturer","backup_initiation.devices[0].model","backup_initiation.devices[0].ocpd_rating","backup_initiation.feeders.is_whole_home_backup","backup_initiation.feeders.material","busbars[0].combiner.contains_ess","busbars[0].combiner.has_dedicated_ocpd","busbars[0].combiner.ix_location","busbars[0].is_already_present"]}},"audit_log":[{"id":901,"ts":"2026-05-06T09:32:18.457174+00:00","stage":"extracting","level":"info","message":"Starting v2 intake (always-Opus extraction)","payload":null},{"id":902,"ts":"2026-05-06T09:32:18.471290+00:00","stage":"asana_fetched","level":"info","message":"Resolving Asana task reference 'https://app.asana.com/1/1203754389657527/project/1211039529104749/task/1211709017140700'","payload":null},{"id":903,"ts":"2026-05-06T09:32:18.890646+00:00","stage":"asana_fetched","level":"info","message":"Loaded Asana task: Teresa Ramirez","payload":{"gid":"1211709017140700","title":"Teresa Ramirez","customer":"Teresa Ramirez"}},{"id":904,"ts":"2026-05-06T09:32:18.898541+00:00","stage":"drive_resolved","level":"info","message":"Searching Asana fields for Google Drive URL","payload":null},{"id":905,"ts":"2026-05-06T09:32:20.356423+00:00","stage":"drive_resolved","level":"info","message":"Resolved Drive folder (8 items, 7 in CAD/)","payload":{"folder_id":"1lcO5aA-VkQ3sJlAZh7r_jXH5laQHAcX_","cad_folder_id":"1QSubAYKQtku-FjHGZL0Y7rTqCilfizul"}},{"id":906,"ts":"2026-05-06T09:32:20.362972+00:00","stage":"pdf_downloaded","level":"info","message":"Picking the latest-dated plan-set PDF","payload":null},{"id":907,"ts":"2026-05-06T09:32:23.008338+00:00","stage":"pdf_downloaded","level":"info","message":"Downloaded plan-set: Teresa Ramirez_V0_12-16-2025.pdf (8.2 MB)","payload":{"bytes":8555492,"filename":"Teresa Ramirez_V0_12-16-2025.pdf"}},{"id":908,"ts":"2026-05-06T09:32:23.014819+00:00","stage":"bom_downloaded","level":"info","message":"Looking for the BOM CSV in the same folder","payload":null},{"id":909,"ts":"2026-05-06T09:32:23.028399+00:00","stage":"bom_downloaded","level":"warn","message":"No BOM CSV in folder — modules section will rely on PDF + Asana only","payload":null},{"id":910,"ts":"2026-05-06T09:32:23.035099+00:00","stage":"ai_extracted","level":"info","message":"Extracting text from the plan-set PDF","payload":null},{"id":911,"ts":"2026-05-06T09:32:28.979463+00:00","stage":"ai_extracted","level":"info","message":"Pass 1/2: Claude Opus 4.7 (full extraction)","payload":null},{"id":912,"ts":"2026-05-06T09:33:40.777220+00:00","stage":"ai_extracted","level":"info","message":"Pass 1: Opus filled 61 fields (avg 87%)","payload":null},{"id":913,"ts":"2026-05-06T09:33:40.796272+00:00","stage":"ai_extracted","level":"info","message":"Pass 2/2: Claude Opus 4.7 retrying 36 missing fields","payload":null},{"id":914,"ts":"2026-05-06T09:34:19.705028+00:00","stage":"ai_extracted","level":"info","message":"Extracted 81 fields, avg confidence 83% (Opus: 61, Opus retry: +20, 16 still unfilled)","payload":{"usage":{"input_tokens":59045,"output_tokens":8779,"cache_read_input_tokens":0,"cache_creation_input_tokens":9856},"fields":81,"passes":{"opus_full":61,"opus_retry":20},"missing":16,"extra_fields":0,"avg_confidence":0.836}},{"id":915,"ts":"2026-05-06T09:34:19.909560+00:00","stage":"creating_draft","level":"info","message":"[DEV] Looking for an existing dev draft in prod…","payload":{"dev_mode":true,"solarapp_mode":"prod"}},{"id":916,"ts":"2026-05-06T09:34:19.940736+00:00","stage":"dev_mode_reuse","level":"warn","message":"[DEV] Reusing existing draft d81c5ac2-28f4-4fa0-afcd-690cfb2b6c08 (used 12× — archive at /audit/dev to start fresh)","payload":{"uuid":"d81c5ac2-28f4-4fa0-afcd-690cfb2b6c08","title":"Michael McMillin — 420 Wood Street","is_reuse":true,"runs_count":12,"project_url":"https://gosolarapp.org/my-projects/d81c5ac2-28f4-4fa0-afcd-690cfb2b6c08/edit"}},{"id":917,"ts":"2026-05-06T09:34:19.947403+00:00","stage":"creating_draft","level":"info","message":"[DEV] Draft reused: d81c5ac2-28f4-4fa0-afcd-690cfb2b6c08","payload":{"uuid":"d81c5ac2-28f4-4fa0-afcd-690cfb2b6c08","is_reuse":true,"project_url":"https://gosolarapp.org/my-projects/d81c5ac2-28f4-4fa0-afcd-690cfb2b6c08/edit"}},{"id":918,"ts":"2026-05-06T09:34:19.969661+00:00","stage":"corpus_loaded","level":"info","message":"Corpus loaded (382 approved projects); archetype matched: SI_NODC_ESS_120R_NOMPU_NEW (score 1.00)","payload":{"archetype_id":"SI_NODC_ESS_120R_NOMPU_NEW","total_projects":382,"archetype_score":1.0,"corpus_block_chars":55911,"archetype_recommended":true}},{"id":919,"ts":"2026-05-06T09:34:19.993881+00:00","stage":"iteration_started","level":"info","message":"Iteration 1 of 2","payload":{"total_max":2,"iteration_no":1}},{"id":920,"ts":"2026-05-06T09:34:26.598316+00:00","stage":"patch_sent","level":"info","message":"PATCHed 63 fields (core)","payload":{"patch_kind":"core","field_count":63,"iteration_no":1}},{"id":921,"ts":"2026-05-06T09:34:26.611709+00:00","stage":"qualification_submitted","level":"info","message":"Submitting for qualification","payload":{"iteration_no":1}},{"id":922,"ts":"2026-05-06T09:34:34.902073+00:00","stage":"failures_received","level":"info","message":"2 fixable, 0 upload","payload":{"fixable":2,"uploads":0,"iteration_no":1}},{"id":923,"ts":"2026-05-06T09:34:34.915271+00:00","stage":"opus_called","level":"info","message":"Sending 2 failure(s) to Opus","payload":{"iteration_no":1,"failure_count":2,"self_correcting":false}},{"id":924,"ts":"2026-05-06T09:35:35.250410+00:00","stage":"opus_returned","level":"info","message":"47 corrections proposed","payload":{"iteration_no":1,"changed_paths":["attestations.comply_with_ahj_fire_bulletin","attestations.comply_with_regulations","attestations.comply_with_solarapp_fire_bulletin","attestations.dc_ac_conductors_copper_and_listed","attestations.dc_converter_inverter_rsd_certified_combo","attestations.dc_strings_egc_minimum_10_awg","attestations.egc_gec_minimum_6_awg_or_protected","attestations.equipment_and_ocpd_rated_22kaic_or_series_rated","attestations.equipment_rated_for_overcurrent_and_installed_per_instructions","attestations.ese_distance_from_doors_windows","attestations.ess_center_of_mass_under_4ft","attestations.ess_fastened_per_manufacturer","attestations.ess_has_adequate_capacity_in_event_of_grid_outtage","attestations.module_mounting_snow_rating","attestations.module_mounting_wind_rating","attestations.new_construction","attestations.pcs_access_concealed_per_code","attestations.pcs_access_restricted_to_qualified_personnel","attestations.pv_arrays_ul_3741_listed","attestations.roof_structure_sound"],"self_correcting":false,"corrections_count":47,"unaddressable_count":0}},{"id":925,"ts":"2026-05-06T09:35:35.278720+00:00","stage":"iteration_completed","level":"info","message":"Iteration 1 done: 47 corrections staged","payload":{"outcome":"continue","iteration_no":1,"self_correcting":false,"corrections_count":47}},{"id":926,"ts":"2026-05-06T09:35:35.297927+00:00","stage":"iteration_started","level":"info","message":"Iteration 2 of 2","payload":{"total_max":2,"iteration_no":2}},{"id":927,"ts":"2026-05-06T09:35:38.219470+00:00","stage":"patch_retry","level":"warn","message":"PATCH got 500 — retrying once after 2s","payload":{"first_error":"HTTP 500 | path=/api/v1/projects/d81c5ac2-28f4-4fa0-afcd-690cfb2b6c08/details | Server Error","iteration_no":2}},{"id":928,"ts":"2026-05-06T09:35:42.894071+00:00","stage":"patch_bisect_started","level":"warn","message":"PATCH 500 persisted — bisecting 13 keys","payload":{"keys":["inverters","storage","modules","backup_initiation","rapid_shutdown_devices","racking","busbars","has_main_panel_upgrade","has_main_breaker_derate","has_trenching","project_valuation","utility","attestations"],"iteration_no":2}},{"id":929,"ts":"2026-05-06T09:35:55.931562+00:00","stage":"patch_bisect_done","level":"warn","message":"Bisect: applied 13 key(s), 0 bad (none)","payload":{"bad_keys":[],"budget_used":6,"applied_keys":["inverters","storage","modules","backup_initiation","rapid_shutdown_devices","racking","busbars","has_main_panel_upgrade","has_main_breaker_derate","has_trenching","project_valuation","utility","attestations"],"iteration_no":2}},{"id":930,"ts":"2026-05-06T09:35:55.939799+00:00","stage":"patch_sent","level":"info","message":"PATCHed 13 fields (delta)","payload":{"patch_kind":"delta","field_count":13,"iteration_no":2}},{"id":931,"ts":"2026-05-06T09:35:55.952188+00:00","stage":"qualification_submitted","level":"info","message":"Submitting for qualification","payload":{"iteration_no":2}},{"id":932,"ts":"2026-05-06T09:36:04.253125+00:00","stage":"failures_received","level":"info","message":"2 fixable, 0 upload","payload":{"fixable":2,"uploads":0,"iteration_no":2}},{"id":933,"ts":"2026-05-06T09:36:04.274067+00:00","stage":"loop_max_reached","level":"warn","message":"2 iterations exhausted, 2 rules remain","payload":{"remaining":2,"iteration_no":2}},{"id":934,"ts":"2026-05-06T09:36:04.291566+00:00","stage":"diagnosis_started","level":"info","message":"Diagnosing 2 remaining rule(s)…","payload":{"remaining":2}},{"id":935,"ts":"2026-05-06T09:36:20.552618+00:00","stage":"diagnosis_completed","level":"info","message":"Diagnosis complete — 2 rule explanation(s)","payload":{"count":2,"rule_ids":["R559","R736"]}},{"id":936,"ts":"2026-05-06T09:36:20.568936+00:00","stage":"awaiting_review","level":"info","message":"Pipeline complete — reached 2-iteration cap with 2 rule(s) still failing. Review fields and submit when ready.","payload":{"outcome":"max_reached","iterations":2,"remaining_fixable":2,"remaining_uploads":0}},{"id":937,"ts":"2026-05-06T09:37:23.744982+00:00","stage":"final_patching","level":"info","message":"Final PATCH /details with reviewed values","payload":null},{"id":938,"ts":"2026-05-06T09:37:30.254715+00:00","stage":"done","level":"info","message":"SolarAPP+ draft updated: https://gosolarapp.org/my-projects/d81c5ac2-28f4-4fa0-afcd-690cfb2b6c08/edit","payload":{"project_url":"https://gosolarapp.org/my-projects/d81c5ac2-28f4-4fa0-afcd-690cfb2b6c08/edit","project_uuid":"d81c5ac2-28f4-4fa0-afcd-690cfb2b6c08"}}],"field_values":[{"payload_key":"Attachment points staggered","source":"inferred","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.6,"edited":false,"reasoning":"Standard Unirac staggered layout typical, not explicitly stated","source_excerpt":null,"in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Backup contains service disconnect","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.7,"edited":false,"reasoning":"Tesla Backup Switch is installed behind the utility meter and acts as a service disconnect for the backup configuration.","source_excerpt":"(N) TESLA BACKUP SWITCH (MICROGRID INTERCONNECTION DEVICE)","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Backup device manufacturer","source":"pdf","raw_value":"Tesla","ai_value":"Tesla","user_value":null,"confidence":0.97,"edited":false,"reasoning":"Tesla Backup Switch","source_excerpt":"TESLA BACKUP SWITCH (MICROGRID INTERCONNECTION DEVICE)","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Backup device model","source":"pdf","raw_value":"Backup Switch","ai_value":"Backup Switch","user_value":null,"confidence":0.92,"edited":false,"reasoning":"Tesla Backup Switch","source_excerpt":"TESLA BACKUP SWITCH","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Backup device OCPD rating (Amps)","source":"pdf","raw_value":"200","ai_value":"200","user_value":null,"confidence":0.8,"edited":false,"reasoning":"Backup switch 200A rating","source_excerpt":"Continuous Load Rating 200 A, 120/240 V split phase","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Backup feeder conductor material","source":"pdf","raw_value":"Copper","ai_value":"Copper","user_value":null,"confidence":0.9,"edited":false,"reasoning":"All copper per plan notes","source_excerpt":"ALL CONDUCTORS COPPER, UNLESS OTHERWISE NOTED","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Busbar #1 already present on site","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.9,"edited":false,"reasoning":"Existing MSP","source_excerpt":"(E) 200A MAIN SERVICE PANEL WITH (E) 70A MAIN BREAKER","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Busbar #1 interconnection compliance method","source":"pdf","raw_value":"120% rule","ai_value":"120% rule","user_value":null,"confidence":0.9,"edited":false,"reasoning":"Plan set explicitly shows 120% rule calculation per NEC 705.12(B)(2).","source_excerpt":"200X1.20=240 BUS RATING x 120% 240-70=170A ALLOWABLE BACKFEED","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Busbar #1 main-lug-only solo main breaker present","source":"pdf","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.8,"edited":false,"reasoning":"MSP has a main breaker (70A), not main-lug-only.","source_excerpt":"(E) 200A MAIN SERVICE PANEL WITH (E) 70A MAIN BREAKER","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Busbar #1 main panel upgrade","source":"asana","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.95,"edited":false,"reasoning":"No MPU","source_excerpt":"MPU: N","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Busbar #1 number of branch circuit breakers","source":"pdf","raw_value":"1","ai_value":"1","user_value":null,"confidence":0.4,"edited":false,"reasoning":"PV interconnection is via 60A breaker into subpanel; only one PV breaker referenced. Verify.","source_excerpt":"(N) 60A BREAKER ... PV BREAKER TIE IN SUB","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Busbar #1 on line side of main service panel","source":"pdf","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.85,"edited":false,"reasoning":"Interconnection is load-side via subpanel breaker.","source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Busbar #1 panel type","source":"pdf","raw_value":"New Subpanel","ai_value":"New Subpanel","user_value":null,"confidence":0.85,"edited":false,"reasoning":"PV backfeed lands on the new 200A subpanel.","source_excerpt":"(N) 200A SUB PANEL ... PV BREAKER TIE IN SUB","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Busbar #1 rating (Amps)","source":"pdf","raw_value":"200","ai_value":"200","user_value":null,"confidence":0.95,"edited":false,"reasoning":"200A bus","source_excerpt":"(E) 200A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Busbar #1 subject to backfeed","source":"pdf","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.7,"edited":false,"reasoning":"Interconnection is at subpanel, not the main","source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Busbar feeder OCPD rating (Amps)","source":"pdf","raw_value":"70","ai_value":"70","user_value":null,"confidence":0.6,"edited":false,"reasoning":"Feeder from MSP to subpanel is protected by the existing 70A main breaker.","source_excerpt":"(E) 70A MAIN BREAKER","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Busbar feeder wire gauge (AWG)","source":"pdf","raw_value":"4","ai_value":"4","user_value":null,"confidence":0.7,"edited":false,"reasoning":"Conductor schedule row 5 shows 4 AWG THWN-2 between sub and main.","source_excerpt":"SUB PANEL TO MAIN PANEL ... 4 AWG THWN-2 COPPER","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Combiner panel contains ESS","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.7,"edited":false,"reasoning":"Powerwall 3 with whole-home backup integrates with the new subpanel.","source_excerpt":"BATTERY CONFIGURATION: WHOLE HOME BACKUP ... TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Combiner panel has dedicated OCPD","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.7,"edited":false,"reasoning":"60A dedicated breaker for PV/ESS interconnection.","source_excerpt":"(N) 60A BREAKER","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Combiner panel interconnection location","source":"pdf","raw_value":"New Subpanel","ai_value":"New Subpanel","user_value":null,"confidence":0.85,"edited":false,"reasoning":"Interconnection is at new 200A subpanel.","source_excerpt":"(N) 200A SUB PANEL ... PV BREAKER TIE IN SUB","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Current roof covering material","source":"pdf","raw_value":"Asphalt or composition shingles","ai_value":"Asphalt or composition shingles","user_value":null,"confidence":0.97,"edited":false,"reasoning":"Comp shingle","source_excerpt":"ROOF TYPE: COMP SHINGLE (MAIN HOME)","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"ESS subject to vehicle damage (alternate)","source":"inferred","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.6,"edited":false,"reasoning":"ESS mounted on east outside wall of house, not in driveway/garage path; standard residential install.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"ESS unit charging from grid","source":"inferred","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.6,"edited":false,"reasoning":"Whole home backup config typically allows grid charging","source_excerpt":null,"in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"ESS unit has dedicated OCPD","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.85,"edited":false,"reasoning":"60A dedicated breaker","source_excerpt":"(N) 60A BREAKER","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"ESS unit installation location (architecture: Energy Storage System)","source":"pdf","raw_value":"Outdoor walls","ai_value":"Outdoor walls","user_value":null,"confidence":0.8,"edited":false,"reasoning":"Mounted on east outside wall","source_excerpt":"EAST OUTSIDE WALL","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"ESS unit interconnection location","source":"pdf","raw_value":"New Subpanel","ai_value":"New Subpanel","user_value":null,"confidence":0.8,"edited":false,"reasoning":"Tied into new subpanel","source_excerpt":"(N) 200A SUB PANEL ... INTERCONNECTION: PV BREAKER TIE IN SUB","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"ESS unit is single unit with inverter","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.95,"edited":false,"reasoning":"Powerwall 3 integrates inverter and battery","source_excerpt":"TESLA POWERWALL 3 ... INVERTER / ENERGY STORAGE SYSTEM","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"ESS unit manufacturer (architecture: Energy Storage System)","source":"pdf","raw_value":"Tesla","ai_value":"Tesla","user_value":null,"confidence":0.97,"edited":false,"reasoning":"Tesla","source_excerpt":"TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"ESS unit model (architecture: Energy Storage System)","source":"pdf","raw_value":"Powerwall 3 (1707000-11-J-DOM)","ai_value":"Powerwall 3 (1707000-11-J-DOM)","user_value":null,"confidence":0.92,"edited":false,"reasoning":"Powerwall 3","source_excerpt":"TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM)","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"ESS unit OCPD rating (Amps)","source":"pdf","raw_value":"60","ai_value":"60","user_value":null,"confidence":0.9,"edited":false,"reasoning":"60A breaker","source_excerpt":"(N) 60A BREAKER","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"ESS unit quantity (architecture: Energy Storage System)","source":"pdf","raw_value":"1","ai_value":"1","user_value":null,"confidence":0.97,"edited":false,"reasoning":"1 unit","source_excerpt":"(N) 01- TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"ESS units have separation less than 3 feet (alternate)","source":"pdf","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.7,"edited":false,"reasoning":"Only one Powerwall 3 unit; per code note, separation maintained. Single unit means N/A but answer No to <3ft.","source_excerpt":"MULTIPLE ESS SYSTEMS SHALL BE SEPARATED FROM EACH OTHER BY AT LEAST 3'","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Flush mount or tilt-up","source":"pdf","raw_value":"Flush mount","ai_value":"Flush mount","user_value":null,"confidence":0.95,"edited":false,"reasoning":"Roof mount with rails per plan","source_excerpt":"PHOTOVOLTAIC ROOF MOUNT SYSTEM","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Home has sprinkler systems","source":"inferred","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.5,"edited":false,"reasoning":"Single-family residence in McFarland CA; residential sprinklers not standard for older homes and not mentioned.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Homeowner Full Name","source":"asana","raw_value":"Teresa Ramirez","ai_value":"Teresa Ramirez","user_value":null,"confidence":0.98,"edited":false,"reasoning":"Asana task name","source_excerpt":"task_name: Teresa Ramirez","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Inverter 1 interconnection location","source":"pdf","raw_value":"New Subpanel","ai_value":"New Subpanel","user_value":null,"confidence":0.85,"edited":false,"reasoning":"PV breaker tie-in to new subpanel","source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Inverter 1 Manufacturer","source":"pdf","raw_value":"Tesla","ai_value":"Tesla","user_value":null,"confidence":0.98,"edited":false,"reasoning":"Tesla Powerwall 3","source_excerpt":"TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM) INVERTER / ENERGY STORAGE SYSTEM","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Inverter 1 Model Number","source":"pdf","raw_value":"1707000-11-J-DOM","ai_value":"1707000-11-J-DOM","user_value":null,"confidence":0.95,"edited":false,"reasoning":"Powerwall 3 model","source_excerpt":"TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM)","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Inverter 1 OCPD rating (Amps)","source":"pdf","raw_value":"60","ai_value":"60","user_value":null,"confidence":0.95,"edited":false,"reasoning":"60A backfeed breaker","source_excerpt":"(N) 60A BREAKER","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Inverter architecture type","source":"inferred","raw_value":"String Inverter without DC-DC Converters","ai_value":"String Inverter without DC-DC Converters","user_value":null,"confidence":0.7,"edited":false,"reasoning":"Powerwall 3 with MCI rapid shutdown devices, treated as string inverter","source_excerpt":null,"in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Inverter output uses NM cable","source":"pdf","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.7,"edited":false,"reasoning":"Inverter AC output runs in EMT with THWN-2, not NM.","source_excerpt":"INVERTER TO AC DISCONNECT ... 3/4\" EMT CONDUIT RUN ... 6 AWG THWN-2","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Main breaker derate applied","source":"pdf","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.8,"edited":false,"reasoning":"120% rule used, no main breaker derate.","source_excerpt":"200X1.20=240 ... 240-70=170A ALLOWABLE BACKFEED","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Max DC PV Wire / USE-2 conductors in raceway (excl. EGC)","source":"pdf","raw_value":"4","ai_value":"4","user_value":null,"confidence":0.8,"edited":false,"reasoning":"4 PV wire conductors","source_excerpt":"1 DC MCI TO JUNCTION BOX 4 - 10 AWG PV WIRE","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Max DC THWN-2 conductors in raceway (excl. EGC)","source":"pdf","raw_value":"4","ai_value":"4","user_value":null,"confidence":0.8,"edited":false,"reasoning":"4 THWN-2 conductors DC","source_excerpt":"2 DC JUNCTION BOX TO INVERTER 4 3/4\" EMT 10 AWG THWN-2","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Maximum distance from module to roof (inches)","source":"pdf","raw_value":"6","ai_value":"6","user_value":null,"confidence":0.85,"edited":false,"reasoning":"Attachment detail max standoff","source_excerpt":"3\" MIN. 6\" MAX.","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Maximum input DC open circuit voltage (Voc) of PV inverter","source":"pdf","raw_value":"600","ai_value":"600","user_value":null,"confidence":0.9,"edited":false,"reasoning":"PW3 max DC voltage","source_excerpt":"Withstand Voltage 600 V DC","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Maximum input DC short circuit current (Isc) of PV inverter","source":"pdf","raw_value":"19","ai_value":"19","user_value":null,"confidence":0.85,"edited":false,"reasoning":"Per MPPT","source_excerpt":"Maximum Short Circuit Current per MPPT (Isc) 19 A","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Maximum number of modules in a DC series string","source":"pdf","raw_value":"7","ai_value":"7","user_value":null,"confidence":0.85,"edited":false,"reasoning":"Largest string is 7 modules","source_excerpt":"(N) 7 MODULES IN BRANCH CIRCUIT #2","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Maximum OCPD rating allowed on Inverter 1 (Amps)","source":"pdf","raw_value":"60","ai_value":"60","user_value":null,"confidence":0.92,"edited":false,"reasoning":"Datasheet OCPD for 11.5 kW model","source_excerpt":"Overcurrent Protection Device 60 A","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Maximum spacing between adjacent attachment points (inches)","source":"pdf","raw_value":"48","ai_value":"48","user_value":null,"confidence":0.9,"edited":false,"reasoning":"Stated max attachment spacing","source_excerpt":"UNIRAC STRONGHOLD BUTYL ATTACHMENTS @ 48\" O.C MAX","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Module 1 Quantity","source":"pdf","raw_value":"13","ai_value":"13","user_value":null,"confidence":0.98,"edited":false,"reasoning":"13 modules","source_excerpt":"(N) 13- QCELLS: Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Module fire rating type","source":"inferred","raw_value":"2","ai_value":"2","user_value":null,"confidence":0.6,"edited":false,"reasoning":"Class 2 typical for Q.Peak modules","source_excerpt":null,"in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Module is bifacial","source":"inferred","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.85,"edited":false,"reasoning":"Q.Peak Duo BLK is monofacial","source_excerpt":null,"in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Module Manufacturer","source":"pdf","raw_value":"Q Cells","ai_value":"Q Cells","user_value":null,"confidence":0.95,"edited":false,"reasoning":"Hanwha Q Cells","source_excerpt":"QCELLS: Q.PEAK DUO BLK ML-G10.C+ 410 (410W) MODULES","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Module Model Number","source":"pdf","raw_value":"Q.PEAK DUO BLK ML-G10.C+ 410","ai_value":"Q.PEAK DUO BLK ML-G10.C+ 410","user_value":null,"confidence":0.95,"edited":false,"reasoning":"Module model","source_excerpt":"Q.PEAK DUO BLK ML-G10.C+ 410 (410W)","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Number of composite shingle layers","source":"inferred","raw_value":"1","ai_value":"1","user_value":null,"confidence":0.6,"edited":false,"reasoning":"Single layer assumed; not stated","source_excerpt":null,"in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"OCPD protecting busbar #1 rating (Amps)","source":"pdf","raw_value":"70","ai_value":"70","user_value":null,"confidence":0.95,"edited":false,"reasoning":"70A main breaker","source_excerpt":"(E) 70A MAIN BREAKER","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Project Address","source":"asana","raw_value":"248 Mount Arbor Street, McFarland, CA 93250","ai_value":"248 Mount Arbor Street, McFarland, CA 93250","user_value":null,"confidence":0.95,"edited":false,"reasoning":"Asana custom fields combined with PDF zip 93250","source_excerpt":"Street: 248 Mount Arbor Street; City: McFarland; State: CA","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Project valuation (USD)","source":"asana","raw_value":"43296","ai_value":"43296","user_value":null,"confidence":0.9,"edited":false,"reasoning":"Contract value","source_excerpt":"Contract Amount: 43296.17","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"PV system weight (lbs/sq ft)","source":"inferred","raw_value":"3","ai_value":"3","user_value":null,"confidence":0.5,"edited":false,"reasoning":"Typical residential rail-mounted PV array distributed dead load is approximately 3 lbs/sq ft.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Racking System Manufacturer","source":"pdf","raw_value":"Unirac","ai_value":"Unirac","user_value":null,"confidence":0.97,"edited":false,"reasoning":"Racking BOM","source_excerpt":"UNIRAC NXT UMOUNT RAIL 168\"","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Racking System Model Number","source":"pdf","raw_value":"NXT UMOUNT","ai_value":"NXT UMOUNT","user_value":null,"confidence":0.95,"edited":false,"reasoning":"Racking model","source_excerpt":"UNIRAC NXT UMOUNT RAIL 168\"-MILL (168RLM1-US)","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Rafter has ceiling joists","source":"pdf","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.6,"edited":false,"reasoning":"Truss roof framing - trusses include integral bottom chord, not separate ceiling joists.","source_excerpt":"ROOF FRAME: 2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Rafter size (nominal)","source":"pdf","raw_value":"2x4","ai_value":"2x4","user_value":null,"confidence":0.95,"edited":false,"reasoning":"Per design criteria","source_excerpt":"2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Rafter spacing (inches)","source":"pdf","raw_value":"24","ai_value":"24","user_value":null,"confidence":0.97,"edited":false,"reasoning":"24 inches OC","source_excerpt":"2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Rafter type","source":"pdf","raw_value":"Engineered truss","ai_value":"Engineered truss","user_value":null,"confidence":0.9,"edited":false,"reasoning":"Truss specified","source_excerpt":"ROOF FRAME: 2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Rapid Shutdown compliance method inside array","source":"pdf","raw_value":"PV Hazard Control System (UL 3741)","ai_value":"PV Hazard Control System (UL 3741)","user_value":null,"confidence":0.7,"edited":false,"reasoning":"Tesla MCI is UL 3741 PVRSA","source_excerpt":"UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array)","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Rapid Shutdown Device Manufacturer","source":"pdf","raw_value":"Tesla","ai_value":"Tesla","user_value":null,"confidence":0.97,"edited":false,"reasoning":"Tesla MCI","source_excerpt":"TESLA MCI-2S (RAPID SHUTDOWN DEVICE)","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Rapid Shutdown Device Model Number","source":"pdf","raw_value":"MCI-2S","ai_value":"MCI-2S","user_value":null,"confidence":0.95,"edited":false,"reasoning":"MCI-2S","source_excerpt":"05 - TESLA MCI-2S (RAPID SHUTDOWN DEVICE)","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Rapid Shutdown Device Quantity","source":"pdf","raw_value":"5","ai_value":"5","user_value":null,"confidence":0.97,"edited":false,"reasoning":"5 devices","source_excerpt":"05 - TESLA MCI-2S","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Roof framing type","source":"pdf","raw_value":"Truss","ai_value":"Truss","user_value":null,"confidence":0.95,"edited":false,"reasoning":"Truss","source_excerpt":"ROOF FRAME: 2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Roof has flat plane","source":"pdf","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.85,"edited":false,"reasoning":"Roof has 18-degree pitch, not flat.","source_excerpt":"ROOFTILT 18°","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Roof penetration sealant method name and description","source":"pdf","raw_value":"Unirac Stronghold Butyl attachment with pre-applied butyl pad","ai_value":"Unirac Stronghold Butyl attachment with pre-applied butyl pad","user_value":null,"confidence":0.9,"edited":false,"reasoning":"Sealant method","source_excerpt":"UNIRAC STRONGHOLD BUTYL ATTACHMENTS","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Roof pitch","source":"pdf","raw_value":"4/12","ai_value":"4/12","user_value":null,"confidence":0.8,"edited":false,"reasoning":"18° ≈ 4/12 pitch","source_excerpt":"ROOF TILT 18°","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Storage architecture","source":"pdf","raw_value":"Energy Storage System","ai_value":"Energy Storage System","user_value":null,"confidence":0.9,"edited":false,"reasoning":"AC-coupled ESS","source_excerpt":"TESLA POWERWALL 3 ... INVERTER / ENERGY STORAGE SYSTEM","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Supply side connection per NEC 705.12(A)","source":"pdf","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.9,"edited":false,"reasoning":"Load-side interconnection per 705.12(B), not supply-side.","source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB ... SEE NEC 705.12(B)(2)","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Total roof area (sq ft)","source":"pdf","raw_value":"1884","ai_value":"1884","user_value":null,"confidence":0.85,"edited":false,"reasoning":"Plan-set roof area rounded","source_excerpt":"AREA OF ROOF (PLAN VIEW)(Sq. Ft.) 1883.98","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Utility available fault current greater than 10 kA at service","source":"inferred","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.6,"edited":false,"reasoning":"Typical residential service <10 kA","source_excerpt":null,"in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Utility company name","source":"asana","raw_value":"Southern California Edison","ai_value":"Southern California Edison","user_value":null,"confidence":0.9,"edited":false,"reasoning":"SCE","source_excerpt":"Utility: SCE (CA)","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Utility service feed rating (Amps)","source":"pdf","raw_value":"200","ai_value":"200","user_value":null,"confidence":0.95,"edited":false,"reasoning":"200A MSP","source_excerpt":"(E) 200A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"},{"payload_key":"Whole home backup","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.97,"edited":false,"reasoning":"Stated whole home backup","source_excerpt":"BATTERY CONFIGURATION: WHOLE HOME BACKUP","in_field_map":true,"updated_at":"2026-05-06T09:34:19.712008+00:00"}],"artifacts":[{"id":136,"kind":"asana_json","local_path":"/data/runs/01KQYA32KVQX28MYAGM00BYNH1/asana.json","drive_file_id":null,"sha256":null,"bytes":39325,"downloaded_at":"2026-05-06T09:32:18.874344+00:00"},{"id":137,"kind":"pdf","local_path":"/data/runs/01KQYA32KVQX28MYAGM00BYNH1/pdf/Teresa_Ramirez_V0_12-16-2025.pdf","drive_file_id":"1p3daAjfHODTGPqqvHtAIAmWQWNu83s9U","sha256":"41acb4f7fafc1047d3c43daf7d286d6f6f49b9f0cfa950d693b252711d0faac4","bytes":8555492,"downloaded_at":"2026-05-06T09:32:22.993459+00:00"},{"id":138,"kind":"extraction","local_path":"/data/runs/01KQYA32KVQX28MYAGM00BYNH1/extraction.json","drive_file_id":null,"sha256":null,"bytes":36111,"downloaded_at":"2026-05-06T09:34:19.695050+00:00"}],"has_final_patch":true,"final_patch_field_count":74,"_meta":{"collected_at":"2026-05-06T22:21:31.991543+00:00","iteration_count":2,"audit_log_count":38,"field_values_count":81,"artifacts_count":3,"has_final_patch":true}}