{"run":{"id":"01KQF123EDH3HHSD52PEESPPX3","asana_task_gid":"1211709017140700","asana_task_url":"https://app.asana.com/1/1203754389657527/project/1211039529104749/task/1211709017140700","asana_task_title":"Teresa Ramirez","customer_name":"Teresa Ramirez","status":"awaiting_review","current_stage":"awaiting_review","drive_folder_id":"1lcO5aA-VkQ3sJlAZh7r_jXH5laQHAcX_","drive_cad_folder_id":"1QSubAYKQtku-FjHGZL0Y7rTqCilfizul","plan_set_filename":"Teresa Ramirez_V0_12-16-2025.pdf","bom_filename":null,"solarapp_uuid":null,"project_url":null,"error_stage":"/api/v1/projects/f2c8212a-d5f6-4ce9-bb14-37ad83b0ab6a/details","error_message":"HTTP 500 | path=/api/v1/projects/f2c8212a-d5f6-4ce9-bb14-37ad83b0ab6a/details | Server Error","error_payload":{"errors":{},"status":500,"request_path":"/api/v1/projects/f2c8212a-d5f6-4ce9-bb14-37ad83b0ab6a/details","solarapp_code":null},"ai_token_usage":{"input_tokens":79128,"output_tokens":10345,"cache_read_input_tokens":0,"cache_creation_input_tokens":9556},"avg_confidence":0.847,"warnings":["Roof pitch derived from 18° tilt (~4/12).","Project address ZIP from PDF (93250) used; Asana lacked ZIP.","Inverter is Tesla Powerwall 3 - integrated PV inverter + ESS in single unit; selected 'String Inverter without DC-DC Converters' but operator should verify SolarAPP+ canonical mapping for Powerwall 3.","Existing PV system on roof is on a separate utility meter per plan set; not modeled here.","Module manufacturer normalized to 'Q Cells' (Hanwha Q Cells).","BOM was empty; all equipment details sourced from PDF plan set and Asana.","Module fire rating type inferred as Class 1 (Class A) based on comp shingle roofing — standard for residential PV in CA.","PV system weight (lbs/sq ft) is a typical design estimate for Unirac NXT UMount on comp shingle; not explicitly stated.","Home sprinkler system status not stated anywhere; inferred No for single-family residential in this area.","Rafter largest span is a rough estimate; structural truss drawings not provided — reviewer should verify.","ESS center of mass < 4 ft: based on wall-mount height of unit (43.5 in height); actual mounting height not specified.","Smoke/heat alarm: inferred from CA code compliance; no explicit plan callout for exterior ESS wall location.","Calculated backup load taken as Powerwall 3 rated output since system is configured for whole home backup.","Busbar feeder interconnection compliance method: 705.12(B)(2) per plan note; exact enum string should be verified against SolarAPP+ catalog.","Supply side connection per NEC 705.12(A) = No because plans explicitly use 705.12(B)(2) load-side method.","Utility fault current > 10 kA: low confidence inference; reviewer should confirm with SCE fault current data.","DC-coupled battery fields skipped — system uses AC-coupled Powerwall 3 (not DC-coupled battery).","Microinverter fields skipped — new system uses Powerwall 3 integrated inverter, not microinverters (existing system has Enphase but that is a separate utility meter/system).","ESS subject to vehicle damage and separation fields: only one ESS unit installed, separation condition not applicable for single unit.","Busbar feeder interconnection compliance method value '705.12(B)(2)' should be matched to exact ix_compliance_method enum in SolarAPP+.","Project has no DC-coupled battery (Powerwall 3 is AC-coupled per Asana 'TESLA 1707000-21 AC BESS' and Powerwall 3 datasheet specs nominal 13.5 kWh AC).","No microinverters on the new system — Tesla MCI-2S are rapid shutdown devices, not microinverters. The existing PV array on the structure uses Enphase IQ8+ microinverters but is on a separate utility meter and not part of this scope.","No supply-side interconnection — plan set clearly indicates load-side PV breaker tie-in to sub panel ('INTERCONNECTION: PV BREAKER TIE IN SUB')."],"flow":"v1","iteration_count":0,"iteration_outcome":null,"final_diagnosis":null,"created_at":"2026-04-30T11:05:52.850726+00:00","updated_at":"2026-04-30T11:24:42.754004+00:00","submitted_at":"2026-04-30T11:23:48.796337+00:00","completed_at":null},"iterations":[],"insights":{"stuck_rules":[],"newly_revealed":[],"conditional_triggers":{}},"audit_log":[{"id":293,"ts":"2026-04-30T11:05:52.859342+00:00","stage":"asana_fetched","level":"info","message":"Resolving Asana task reference 'https://app.asana.com/1/1203754389657527/project/1211039529104749/task/1211709017140700'","payload":null},{"id":294,"ts":"2026-04-30T11:05:53.614172+00:00","stage":"asana_fetched","level":"info","message":"Loaded Asana task: Teresa Ramirez","payload":{"gid":"1211709017140700","title":"Teresa Ramirez","customer":"Teresa Ramirez"}},{"id":295,"ts":"2026-04-30T11:05:53.621719+00:00","stage":"drive_resolved","level":"info","message":"Searching Asana fields for Google Drive URL","payload":null},{"id":296,"ts":"2026-04-30T11:05:55.027518+00:00","stage":"drive_resolved","level":"info","message":"Resolved Drive folder (8 items, 7 in CAD/)","payload":{"folder_id":"1lcO5aA-VkQ3sJlAZh7r_jXH5laQHAcX_","cad_folder_id":"1QSubAYKQtku-FjHGZL0Y7rTqCilfizul"}},{"id":297,"ts":"2026-04-30T11:05:55.034796+00:00","stage":"pdf_downloaded","level":"info","message":"Picking the latest-dated plan-set PDF","payload":null},{"id":298,"ts":"2026-04-30T11:05:56.868380+00:00","stage":"pdf_downloaded","level":"info","message":"Downloaded plan-set: Teresa Ramirez_V0_12-16-2025.pdf (8.2 MB)","payload":{"bytes":8555492,"filename":"Teresa Ramirez_V0_12-16-2025.pdf"}},{"id":299,"ts":"2026-04-30T11:05:56.874698+00:00","stage":"bom_downloaded","level":"info","message":"Looking for the BOM CSV in the same folder","payload":null},{"id":300,"ts":"2026-04-30T11:05:56.887110+00:00","stage":"bom_downloaded","level":"warn","message":"No BOM CSV in folder — modules section will rely on PDF + Asana only","payload":null},{"id":301,"ts":"2026-04-30T11:05:56.894861+00:00","stage":"ai_extracted","level":"info","message":"Extracting text from the plan-set PDF","payload":null},{"id":302,"ts":"2026-04-30T11:06:03.237320+00:00","stage":"ai_extracted","level":"info","message":"Pass 1/3: Claude Opus 4.7 (full extraction)","payload":null},{"id":303,"ts":"2026-04-30T11:07:10.372277+00:00","stage":"ai_extracted","level":"info","message":"Pass 1: Opus filled 66 fields (avg 87%)","payload":null},{"id":304,"ts":"2026-04-30T11:07:10.388161+00:00","stage":"ai_extracted","level":"info","message":"Pass 2/3: Claude Sonnet 4.6 retrying 48 missing fields","payload":null},{"id":305,"ts":"2026-04-30T11:08:19.802687+00:00","stage":"ai_extracted","level":"info","message":"Pass 2: Sonnet added 35 more fields","payload":null},{"id":306,"ts":"2026-04-30T11:08:19.819095+00:00","stage":"ai_extracted","level":"info","message":"Pass 3/3: Claude Opus 4.7 final retry on 13 stubborn fields","payload":null},{"id":307,"ts":"2026-04-30T11:08:32.737674+00:00","stage":"ai_extracted","level":"info","message":"Extracted 103 fields, avg confidence 84% (Opus: 66, Sonnet retry: +35, Opus retry: +2, 11 still unfilled)","payload":{"usage":{"input_tokens":79128,"output_tokens":10345,"cache_read_input_tokens":0,"cache_creation_input_tokens":9556},"fields":103,"passes":{"opus_full":66,"opus_retry":2,"sonnet_retry":35},"missing":11,"extra_fields":0,"avg_confidence":0.847}},{"id":308,"ts":"2026-04-30T11:08:32.752418+00:00","stage":"awaiting_review","level":"info","message":"Pipeline complete — review the extracted fields and submit when ready","payload":null},{"id":309,"ts":"2026-04-30T11:08:43.419506+00:00","stage":"submitting","level":"info","message":"Building SolarAPP+ payload from reviewed fields","payload":null},{"id":310,"ts":"2026-04-30T11:08:43.444185+00:00","stage":"submitting","level":"info","message":"Calling SolarAPP+ create_project + PATCH /details","payload":null},{"id":311,"ts":"2026-04-30T11:09:54.931927+00:00","stage":"submitting","level":"error","message":"SolarAPP+ rejected the submission: HTTP 500 | path=/api/v1/projects/f2c8212a-d5f6-4ce9-bb14-37ad83b0ab6a/details | Server Error","payload":null},{"id":312,"ts":"2026-04-30T11:23:49.045891+00:00","stage":"submitting","level":"info","message":"Building SolarAPP+ payload from reviewed fields","payload":null},{"id":313,"ts":"2026-04-30T11:23:49.075942+00:00","stage":"submitting","level":"info","message":"Calling SolarAPP+ create_project + PATCH /details","payload":null},{"id":314,"ts":"2026-04-30T11:24:42.762881+00:00","stage":"submitting","level":"error","message":"SolarAPP+ rejected the submission: HTTP 500 | path=/api/v1/projects/f2c8212a-d5f6-4ce9-bb14-37ad83b0ab6a/details | Server Error","payload":null}],"field_values":[{"payload_key":"Attachment points staggered","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.5,"edited":true,"reasoning":null,"source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Backup contains service disconnect","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.88,"edited":true,"reasoning":null,"source_excerpt":"(N) TESLA BACKUP SWITCH (MICROGRID INTERCONNECTION DEVICE) ... The Tesla Backup Switch controls connection to the grid in a Powerwall system","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Backup device manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"(N) TESLA BACKUP SWITCH (MICROGRID INTERCONNECTION DEVICE)","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Backup device model","source":"user","raw_value":"Backup Switch","ai_value":"Backup Switch","user_value":"Backup Switch","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"TESLA BACKUP SWITCH","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Backup device OCPD rating (Amps)","source":"user","raw_value":"200","ai_value":"200","user_value":"200","confidence":0.82,"edited":true,"reasoning":null,"source_excerpt":"Continuous Load Rating 200 A, 120/240 V split phase","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Backup feeder conductor material","source":"user","raw_value":"Copper","ai_value":"Copper","user_value":"Copper","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"ALL CONDUCTORS COPPER, UNLESS OTHERWISE NOTED","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Busbar #1 already present on site","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL WITH (E) 70A MAIN BREAKER","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Busbar #1 interconnection compliance method","source":"user","raw_value":"120% rule","ai_value":"120% rule","user_value":"120% rule","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"200X1.20=240 BUS RATING x 120% 240-70=170A ALLOWABLE BACKFEED","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Busbar #1 main-lug-only solo main breaker present","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.7,"edited":true,"reasoning":"The new sub panel has a 60A PV breaker shown; it is a standard load-center sub panel, not a main-lug-only configuration described as solo main breaker.","source_excerpt":"(N) 200A SUB PANEL ... (N) 60A BREAKER","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Busbar #1 main panel upgrade","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"MPU: N","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Busbar #1 number of branch circuit breakers","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.72,"edited":true,"reasoning":"The new sub panel is shown with a 60A PV breaker as the primary/described breaker for PV interconnection. Only one PV backfeed breaker is shown on the sub panel.","source_excerpt":"(N) 60A BREAKER ... (N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Busbar #1 on line side of main service panel","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB ... (E) 200A MAIN SERVICE PANEL WITH (E) 70A MAIN BREAKER ... (N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Busbar #1 panel type","source":"user","raw_value":"Main Service Panel","ai_value":"Main Service Panel","user_value":"Main Service Panel","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL WITH (E) 70A MAIN BREAKER","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Busbar #1 rating (Amps)","source":"user","raw_value":"200","ai_value":"200","user_value":"200","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Busbar #1 subject to backfeed","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Busbar feeder interconnection compliance method","source":"pdf","raw_value":"705.12(B)(2)","ai_value":"705.12(B)(2)","user_value":null,"confidence":0.82,"edited":false,"reasoning":null,"source_excerpt":"SEE NEC 705.12(B)(2) OF 2026 NEC ... 200X1.20=240 BUS RATING x 120% ... 240-70=170A ALLOWABLE BACKFEED","in_field_map":true,"updated_at":"2026-04-30T11:08:32.471777+00:00"},{"payload_key":"Busbar feeder max THWN-2 conductors in raceway","source":"user","raw_value":"3","ai_value":"3","user_value":"3","confidence":0.92,"edited":true,"reasoning":null,"source_excerpt":"RACEWAY 5 AC SUB PANEL TO MAIN PANEL 3 1\" EMT CONDUIT RUN 4 AWG THWN-2 COPPER","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Busbar feeder OCPD rating (Amps)","source":"user","raw_value":"70","ai_value":"70","user_value":"70","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL WITH (E) 70A MAIN BREAKER ... RACEWAY 5: SUB PANEL TO MAIN PANEL 4 AWG THWN-2 ... 70.00","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Busbar feeder wire gauge (AWG)","source":"user","raw_value":"4","ai_value":"4","user_value":"4","confidence":0.92,"edited":true,"reasoning":null,"source_excerpt":"RACEWAY 5 AC SUB PANEL TO MAIN PANEL 3 1\" EMT CONDUIT RUN 4 AWG THWN-2 COPPER","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Calculated backup load (Watts)","source":"user","raw_value":"11500","ai_value":"11500","user_value":"11500","confidence":0.72,"edited":true,"reasoning":"Whole home backup configuration; Powerwall 3 rated at 11,500 W continuous AC output.","source_excerpt":"BATTERY CONFIGURATION: WHOLE HOME BACKUP ... Nominal Output Power (AC) 11.5 kW","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Combiner panel contains ESS","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.75,"edited":true,"reasoning":"The ESS (Powerwall 3) is a separate unit from the sub panel; the sub panel is a standard load-center, not the ESS enclosure.","source_excerpt":"(N) 200A SUB PANEL ... (N) TESLA POWERWALL 3 ... INVERTER / ENERGY STORAGE SYSTEM","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Combiner panel has dedicated OCPD","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"(N) 60A BREAKER ... (N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Combiner panel interconnection location","source":"user","raw_value":"New Subpanel","ai_value":"New Subpanel","user_value":"New Subpanel","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB ... (N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Current roof covering material","source":"user","raw_value":"Asphalt or composition shingles","ai_value":"Asphalt or composition shingles","user_value":"Asphalt or composition shingles","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"ROOF TYPE: COMP SHINGLE (MAIN HOME)","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Each ESS unit has dedicated OCPD","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.7,"edited":true,"reasoning":null,"source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS assembly weight (lbs)","source":"user","raw_value":"291","ai_value":"291","user_value":"291","confidence":0.92,"edited":true,"reasoning":null,"source_excerpt":"Total Weight of Installed Unit 132 kg (291.2 lb)","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS center of mass less than 4 feet from floor","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.75,"edited":true,"reasoning":"Unit height is 43.5 inches (~3.6 ft). Wall-mounted unit's center of mass would typically be at roughly mid-height; if floor-mounted or low wall-mount the CoM would be under 4 ft.","source_excerpt":"Dimensions 1105 x 609 x 193 mm (43.5 x 24 x 7.6 in) ... Mounting Options Floor or wall mount","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS in sleeping rooms or closets opening to sleeping rooms","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS installation location","source":"user","raw_value":"Outdoor walls","ai_value":"Outdoor walls","user_value":"Outdoor walls","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"EAST OUTSIDE WALL ... TESLA POWERWALL","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS location subject to vehicle damage","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.7,"edited":true,"reasoning":null,"source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS Model 1 includes DC-coupled expansion unit","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.8,"edited":true,"reasoning":null,"source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS Model 1 Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS Model 1 Number","source":"user","raw_value":"1707000-11-J-DOM","ai_value":"1707000-11-J-DOM","user_value":"1707000-11-J-DOM","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM)","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS Model 1 Quantity","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"(N) 01- TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS positively attached to building per manufacturer","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"TESLA POWERWALL MOUNTING BRACKET (4) 1/4\" X 3\" LAG BOLTS","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS + PV Inverter certified as single unit (no field wiring)","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.8,"edited":true,"reasoning":null,"source_excerpt":"INVERTER / ENERGY STORAGE SYSTEM (single unit)","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS subject to vehicle damage (alternate)","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.7,"edited":true,"reasoning":"Powerwall 3 mounted on east outside wall of dwelling, not in driveway/garage area subject to vehicle damage.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS unit charging from grid","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"BATTERY CONFIGURATION: WHOLE HOME BACKUP ... Maximum Continuous Charge Current / Power (Powerwall 3 only) 20.8 A AC / 5 kW","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS unit has dedicated OCPD","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"Overcurrent Protection Device 60 A ... (N) 60A BREAKER","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS unit installation location (architecture: Energy Storage System)","source":"user","raw_value":"Outdoor walls","ai_value":"Outdoor walls","user_value":"Outdoor walls","confidence":0.82,"edited":true,"reasoning":null,"source_excerpt":"EAST OUTSIDE WALL ... TESLA POWERWALL MOUNTING BRACKET (4) 1/4\" X 3\" LAG BOLTS W/ MINIMUM 2-1/2\" EMBEDMENT","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS unit interconnection location","source":"user","raw_value":"New Subpanel","ai_value":"New Subpanel","user_value":"New Subpanel","confidence":0.88,"edited":true,"reasoning":null,"source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB ... (N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS unit is single unit with inverter","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.97,"edited":true,"reasoning":null,"source_excerpt":"TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM) INVERTER / ENERGY STORAGE SYSTEM","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS unit manufacturer (architecture: Energy Storage System)","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.97,"edited":true,"reasoning":null,"source_excerpt":"(N) TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM) INVERTER / ENERGY STORAGE SYSTEM","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS unit model (architecture: Energy Storage System)","source":"user","raw_value":"Powerwall 3","ai_value":"Powerwall 3","user_value":"Powerwall 3","confidence":0.97,"edited":true,"reasoning":null,"source_excerpt":"(N) TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM) INVERTER / ENERGY STORAGE SYSTEM","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS unit OCPD rating (Amps)","source":"user","raw_value":"60","ai_value":"60","user_value":"60","confidence":0.92,"edited":true,"reasoning":null,"source_excerpt":"Overcurrent Protection Device 60 A ... BACKFEED BREAKER SIZING ... 60A PV BREAKER - OK","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS unit quantity (architecture: Energy Storage System)","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.97,"edited":true,"reasoning":null,"source_excerpt":"(N) 01- TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM) INVERTER / ENERGY STORAGE SYSTEM","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"ESS units have separation less than 3 feet (alternate)","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.6,"edited":true,"reasoning":"Plan note specifies multiple ESS units must be separated by at least 3 ft; only one Powerwall 3 unit is installed so this is N/A but defaulting to No.","source_excerpt":"MULTIPLE ESS SYSTEMS SHALL BE SEPARATED FROM EACH OTHER BY AT LEAST 3'","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Flush mount or tilt-up","source":"user","raw_value":"Flush mount","ai_value":"Flush mount","user_value":"Flush mount","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"PHOTOVOLTAIC ROOF MOUNT SYSTEM","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Home has sprinkler systems","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.45,"edited":true,"reasoning":"Single-family residential in McFarland, CA. No mention of sprinkler systems anywhere in the plan set or Asana. Residential sprinkler systems are uncommon in this area/vintage and not noted.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Homeowner Full Name","source":"user","raw_value":"Teresa Ramirez","ai_value":"Teresa Ramirez","user_value":"Teresa Ramirez","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"Customer Name: Teresa Ramirez","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Inverter 1 interconnection location","source":"user","raw_value":"New Subpanel","ai_value":"New Subpanel","user_value":"New Subpanel","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB ... (N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Inverter 1 Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM) INVERTER / ENERGY STORAGE SYSTEM","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Inverter 1 Model Number","source":"user","raw_value":"1707000-11-J-DOM","ai_value":"1707000-11-J-DOM","user_value":"1707000-11-J-DOM","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"TESLA POWERWALL 3 ... (1707000-11-J-DOM)","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Inverter 1 OCPD rating (Amps)","source":"user","raw_value":"60","ai_value":"60","user_value":"60","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"60A PV BREAKER - OK","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Inverter 1 power setting (kW)","source":"user","raw_value":"11.5","ai_value":"11.5","user_value":"11.5","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"SYSTEM SIZE AC: -01x 11500W= 11.500 kWAC","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Inverter architecture type","source":"user","raw_value":"String Inverter without DC-DC Converters","ai_value":"String Inverter without DC-DC Converters","user_value":"String Inverter without DC-DC Converters","confidence":0.7,"edited":true,"reasoning":null,"source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Inverter output uses NM cable","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.82,"edited":true,"reasoning":null,"source_excerpt":"3/4\" EMT CONDUIT RUN 7/8\" ABOVE ROOF ... (G) NO PVC ALLOWED ON ROOF OR IN ATTIC ... (N) NM-B OR PAPER INSULATED CONDUCTORS MAY NOT BE USED ON EXTERIOR.","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Main breaker derate applied","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.78,"edited":true,"reasoning":"The plan shows 120% rule compliance, not a main breaker derate. The calculation uses the busbar rating × 1.2 minus main breaker method, not the derate method per 705.12(B)(2)(3)(c).","source_excerpt":"200X1.20=240 BUS RATING x 120% 240-70=170A ALLOWABLE BACKFEED ... 60A PV BREAKER - OK","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Max DC PV Wire / USE-2 conductors in raceway (excl. EGC)","source":"user","raw_value":"4","ai_value":"4","user_value":"4","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"DC MCI TO JUNCTION BOX 4- 10 AWG PV WIRE","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Max DC THWN-2 conductors in raceway (excl. EGC)","source":"user","raw_value":"4","ai_value":"4","user_value":"4","confidence":0.8,"edited":true,"reasoning":null,"source_excerpt":"DC JUNCTION BOX TO INVERTER 4 ... 10 AWG THWN-2","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Maximum distance from module to roof (inches)","source":"user","raw_value":"6","ai_value":"6","user_value":"6","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"3\" MIN. 6\" MAX.","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Maximum input DC open circuit voltage (Voc) of PV inverter","source":"user","raw_value":"600","ai_value":"600","user_value":"600","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"Withstand Voltage 600 V DC","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Maximum input DC short circuit current (Isc) of PV inverter","source":"user","raw_value":"19","ai_value":"19","user_value":"19","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"Maximum Short Circuit Current per MPPT (Isc) 19 A","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Maximum number of modules in a DC series string","source":"user","raw_value":"7","ai_value":"7","user_value":"7","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"(N) 7 MODULES IN BRANCH CIRCUIT #2","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Maximum OCPD rating allowed on Inverter 1 (Amps)","source":"user","raw_value":"60","ai_value":"60","user_value":"60","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"Overcurrent Protection Device 60 A","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Maximum spacing between adjacent attachment points (inches)","source":"user","raw_value":"48","ai_value":"48","user_value":"48","confidence":0.92,"edited":true,"reasoning":null,"source_excerpt":"UNIRAC STRONGHOLD BUTYL ATTACHMENTS @ 48\" O.C MAX","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Module 1 Quantity","source":"user","raw_value":"13","ai_value":"13","user_value":"13","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"(N) 13- QCELLS: Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Module fire rating type","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.85,"edited":true,"reasoning":"Roof material is comp shingle (composite shingle), which is a Class A rated roofing material. PV modules installed on Class A roofing are considered Class A (fire rating type 1) per standard residential PV practice and UL 1703/UL 61730 ratings.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Module is bifacial","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Module Manufacturer","source":"user","raw_value":"Q Cells","ai_value":"Q Cells","user_value":"Q Cells","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"QCELLS: Q.PEAK DUO BLK ML-G10.C+ 410 (410W) MODULES","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Module Model Number","source":"user","raw_value":"Q.PEAK DUO BLK ML-G10.C+ 410","ai_value":"Q.PEAK DUO BLK ML-G10.C+ 410","user_value":"Q.PEAK DUO BLK ML-G10.C+ 410","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"QCELLS: Q.PEAK DUO BLK ML-G10.C+ 410 (410W) MODULES","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Number of composite shingle layers","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.6,"edited":true,"reasoning":null,"source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Number of distinct ESS models","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"(N) 01- TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"OCPD protecting busbar #1 rating (Amps)","source":"user","raw_value":"70","ai_value":"70","user_value":"70","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"(E) 70A MAIN BREAKER","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Project Address","source":"user","raw_value":"248 Mount Arbor St, McFarland, CA 93250","ai_value":"248 Mount Arbor St, McFarland, CA 93250","user_value":"248 Mount Arbor St, McFarland, CA 93250","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"Street: 248 Mount Arbor Street, City: McFarland, State: CA","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Project valuation (USD)","source":"user","raw_value":"43296","ai_value":"43296","user_value":"43296","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"Contract price: $43,296.17","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"PV system weight (lbs/sq ft)","source":"user","raw_value":"4.0","ai_value":"4.0","user_value":"4.0","confidence":0.55,"edited":true,"reasoning":"No explicit weight per sq ft stated. Unirac NXT UMount with comp shingle roof is typically ~3.5-4.5 lbs/sq ft for module+racking. 4.0 is a common design-standard estimate for this racking type.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Racking System Manufacturer","source":"user","raw_value":"Unirac","ai_value":"Unirac","user_value":"Unirac","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"UNIRAC NXT UMOUNT RAIL 168\"","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Racking System Model Number","source":"user","raw_value":"NXT UMOUNT","ai_value":"NXT UMOUNT","user_value":"NXT UMOUNT","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"UNIRAC NXT UMOUNT RAIL 168\"-MILL (168RLM1-US)","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Rafter has ceiling joists","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.72,"edited":true,"reasoning":"Roof frame is truss construction, not conventional rafters with separate ceiling joists. Trusses are self-contained structural members.","source_excerpt":"ROOF FRAME: 2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Rafter largest span (feet)","source":"user","raw_value":"24.0","ai_value":"24.0","user_value":"24.0","confidence":0.42,"edited":true,"reasoning":"No explicit rafter span stated. 2x4 truss at 24\" O.C. for a typical single-story California home in this size range would have truss spans commonly in the 20-28 ft range. Cannot determine precisely without structural drawings.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Rafter size (nominal)","source":"user","raw_value":"2x4","ai_value":"2x4","user_value":"2x4","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"ROOF FRAME: 2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Rafter spacing (inches)","source":"user","raw_value":"24","ai_value":"24","user_value":"24","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Rafter type","source":"user","raw_value":"Engineered truss","ai_value":"Engineered truss","user_value":"Engineered truss","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"ROOF FRAME: 2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Rapid Shutdown compliance method inside array","source":"user","raw_value":"PVRSE (Mid-Circuit Interrupters per NEC 690.12)","ai_value":"PVRSE (Mid-Circuit Interrupters per NEC 690.12)","user_value":"PVRSE (Mid-Circuit Interrupters per NEC 690.12)","confidence":0.7,"edited":true,"reasoning":null,"source_excerpt":"UL 1741 PVRSE, UL 3741, PVRSA","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Rapid Shutdown Device Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"TESLA MCI-2S (RAPID SHUTDOWN DEVICE)","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Rapid Shutdown Device Model Number","source":"user","raw_value":"MCI-2S","ai_value":"MCI-2S","user_value":"MCI-2S","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"TESLA MCI-2S (RAPID SHUTDOWN DEVICE)","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Rapid Shutdown Device Quantity","source":"user","raw_value":"5","ai_value":"5","user_value":"5","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"(N) 05- TESLA MCI-2S (RAPID SHUTDOWN DEVICE)","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Roof framing type","source":"user","raw_value":"Truss","ai_value":"Truss","user_value":"Truss","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"2X4 TRUSS @ 24\" O.C.","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Roof has flat plane","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Roof tilt is 18 degrees, confirming it is a pitched (non-flat) roof.","source_excerpt":"ROOF TILT #1 13 90° 18°","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Roof penetration sealant method name and description","source":"user","raw_value":"Unirac Stronghold Butyl attachment with pre-applied butyl pad","ai_value":"Unirac Stronghold Butyl attachment with pre-applied butyl pad","user_value":"Unirac Stronghold Butyl attachment with pre-applied butyl pad","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"STRONGHOLD BUTYL ATTACHMENTS ... Pre-attached butyl pad","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Roof pitch","source":"user","raw_value":"4/12","ai_value":"4/12","user_value":"4/12","confidence":0.75,"edited":true,"reasoning":null,"source_excerpt":"ROOF TILT 18° (≈4/12)","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Separation between ESS units less than 3 feet","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"MULTIPLE ESS SYSTEMS SHALL BE SEPARATED FROM EACH OTHER BY AT LEAST 3'","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Smoke/heat alarm present at ESS location","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.55,"edited":true,"reasoning":"California residential code requires smoke alarms throughout the home. ESS is on exterior wall, but CA code and CRC R328 compliance implies alarm coverage. No explicit statement found; inferring compliance with code.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Storage architecture","source":"user","raw_value":"Energy Storage System","ai_value":"Energy Storage System","user_value":"Energy Storage System","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Supply side connection per NEC 705.12(A)","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.88,"edited":true,"reasoning":null,"source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB ... SEE NEC 705.12(B)(2) OF 2026 NEC","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"THWN-2 conductors in PV inverter AC output circuit raceway (excl. EGC)","source":"user","raw_value":"3","ai_value":"3","user_value":"3","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"AC INVERTER TO AC DISCONNECT 3 ... 6 AWG THWN-2","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Total roof area (sq ft)","source":"user","raw_value":"1884","ai_value":"1884","user_value":"1884","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"AREA OF ROOF (PLAN VIEW) (Sq. Ft.) 1883.98","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Using Power Control System to curtail Inverter 1","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.6,"edited":true,"reasoning":null,"source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Utility available fault current greater than 10 kA at service","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.62,"edited":true,"reasoning":"The Powerwall 3 datasheet lists maximum short-circuit current rating of 10 kA. Backup Switch rated at 22 kA with breaker. No explicit utility fault current statement; SCE residential services in rural CA typically at or below 10 kA. Inferring not greater than 10 kA.","source_excerpt":"Maximum Short-Circuit Current Rating 10 kA","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Utility company name","source":"user","raw_value":"Southern California Edison","ai_value":"Southern California Edison","user_value":"Southern California Edison","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"Utility: SCE  (CA)","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Utility service feed rating (Amps)","source":"user","raw_value":"200","ai_value":"200","user_value":"200","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"},{"payload_key":"Whole home backup","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"BATTERY CONFIGURATION: WHOLE HOME BACKUP","in_field_map":true,"updated_at":"2026-04-30T11:23:48.796337+00:00"}],"artifacts":[{"id":63,"kind":"asana_json","local_path":"/data/runs/01KQF123EDH3HHSD52PEESPPX3/asana.json","drive_file_id":null,"sha256":null,"bytes":39033,"downloaded_at":"2026-04-30T11:05:53.599904+00:00"},{"id":64,"kind":"pdf","local_path":"/data/runs/01KQF123EDH3HHSD52PEESPPX3/pdf/Teresa_Ramirez_V0_12-16-2025.pdf","drive_file_id":"1p3daAjfHODTGPqqvHtAIAmWQWNu83s9U","sha256":"41acb4f7fafc1047d3c43daf7d286d6f6f49b9f0cfa950d693b252711d0faac4","bytes":8555492,"downloaded_at":"2026-04-30T11:05:56.848252+00:00"},{"id":65,"kind":"extraction","local_path":"/data/runs/01KQF123EDH3HHSD52PEESPPX3/extraction.json","drive_file_id":null,"sha256":null,"bytes":42183,"downloaded_at":"2026-04-30T11:08:32.460381+00:00"}],"has_final_patch":false,"final_patch_field_count":0,"_meta":{"collected_at":"2026-05-06T22:20:18.962023+00:00","iteration_count":0,"audit_log_count":22,"field_values_count":103,"artifacts_count":3,"has_final_patch":false}}