{"run":{"id":"01KQEY2BDDRYYRNFN0HKGTTDNV","asana_task_gid":"1211709017140700","asana_task_url":"https://app.asana.com/1/1203754389657527/project/1211039529104749/task/1211709017140700","asana_task_title":"Teresa Ramirez","customer_name":"Teresa Ramirez","status":"done","current_stage":"done","drive_folder_id":"1lcO5aA-VkQ3sJlAZh7r_jXH5laQHAcX_","drive_cad_folder_id":"1QSubAYKQtku-FjHGZL0Y7rTqCilfizul","plan_set_filename":"Teresa Ramirez_V0_12-16-2025.pdf","bom_filename":null,"solarapp_uuid":"4d1a158e-e76f-45d5-87aa-b56f14a8d212","project_url":"https://gosolarapp.org/my-projects/4d1a158e-e76f-45d5-87aa-b56f14a8d212/edit","error_stage":null,"error_message":null,"error_payload":null,"ai_token_usage":{"input_tokens":46931,"output_tokens":7686,"cache_read_input_tokens":0,"cache_creation_input_tokens":5663},"avg_confidence":0.825,"warnings":["BOM CSV was empty; equipment values pulled from plan-set PDF.","Roof pitch derived from 18° tilt (~3.9/12); rounded to 4/12.","OCPD protecting busbar #1: subpanel is fed from MSP through Tesla Backup Switch with 70A main; verify with reviewer.","Module bifacial inferred as No (Q.PEAK DUO BLK ML-G10.C+ is a monofacial all-black module).","Total roof area uses plan view area for the array roof plane (1883.98 sq ft); whole-home roof area not separately stated.","BOM CSV was empty; all equipment data sourced from plan-set PDF text.","Maximum distance from module to roof: no explicit dimension stated in plans; 6 inches is inferred from Unirac NXT Umount typical standoff height — reviewer should verify against actual installation or manufacturer spec sheet.","PV system weight (lbs/sq ft): calculated from estimated module weight (44 lbs each from typical QCells G10+ spec) divided by array footprint area from plan. Reviewer should verify against QCells module datasheet weight.","Module Isc per MPPT is 19A per Tesla Powerwall 3 datasheet; when MPPTs are combined via jumper, rating doubles to 38A Isc — the 19A figure reflects the standard single-MPPT configuration used in this design.","Number of composite shingle layers defaulted to 1 as no re-roof or double-layer indication found in any source.","Attachment points staggered: standard practice for Unirac NXT Umount but not explicitly stated in plans — reviewer should confirm.","ESS center of mass <4 ft: inferred from wall-mount configuration; reviewer should confirm installation height from finished floor."],"flow":"v1","iteration_count":0,"iteration_outcome":null,"final_diagnosis":null,"created_at":"2026-04-30T10:13:35.281005+00:00","updated_at":"2026-04-30T10:17:49.159639+00:00","submitted_at":"2026-04-30T10:16:12.782885+00:00","completed_at":"2026-04-30T10:17:49.159639+00:00"},"iterations":[],"insights":{"stuck_rules":[],"newly_revealed":[],"conditional_triggers":{}},"audit_log":[{"id":253,"ts":"2026-04-30T10:13:35.291823+00:00","stage":"asana_fetched","level":"info","message":"Resolving Asana task reference 'https://app.asana.com/1/1203754389657527/project/1211039529104749/task/1211709017140700'","payload":null},{"id":254,"ts":"2026-04-30T10:13:35.891735+00:00","stage":"asana_fetched","level":"info","message":"Loaded Asana task: Teresa Ramirez","payload":{"gid":"1211709017140700","title":"Teresa Ramirez","customer":"Teresa Ramirez"}},{"id":255,"ts":"2026-04-30T10:13:35.898202+00:00","stage":"drive_resolved","level":"info","message":"Searching Asana fields for Google Drive URL","payload":null},{"id":256,"ts":"2026-04-30T10:13:37.251365+00:00","stage":"drive_resolved","level":"info","message":"Resolved Drive folder (8 items, 7 in CAD/)","payload":{"folder_id":"1lcO5aA-VkQ3sJlAZh7r_jXH5laQHAcX_","cad_folder_id":"1QSubAYKQtku-FjHGZL0Y7rTqCilfizul"}},{"id":257,"ts":"2026-04-30T10:13:37.257898+00:00","stage":"pdf_downloaded","level":"info","message":"Picking the latest-dated plan-set PDF","payload":null},{"id":258,"ts":"2026-04-30T10:13:39.281378+00:00","stage":"pdf_downloaded","level":"info","message":"Downloaded plan-set: Teresa Ramirez_V0_12-16-2025.pdf (8.2 MB)","payload":{"bytes":8555492,"filename":"Teresa Ramirez_V0_12-16-2025.pdf"}},{"id":259,"ts":"2026-04-30T10:13:39.291097+00:00","stage":"bom_downloaded","level":"info","message":"Looking for the BOM CSV in the same folder","payload":null},{"id":260,"ts":"2026-04-30T10:13:39.304140+00:00","stage":"bom_downloaded","level":"warn","message":"No BOM CSV in folder — modules section will rely on PDF + Asana only","payload":null},{"id":261,"ts":"2026-04-30T10:13:39.319029+00:00","stage":"ai_extracted","level":"info","message":"Extracting text from the plan-set PDF","payload":null},{"id":262,"ts":"2026-04-30T10:13:45.184779+00:00","stage":"ai_extracted","level":"info","message":"Pass 1/3: Claude Opus 4.7 (full extraction)","payload":null},{"id":263,"ts":"2026-04-30T10:14:57.747990+00:00","stage":"ai_extracted","level":"info","message":"Pass 1: Opus filled 50 fields (avg 85%)","payload":null},{"id":264,"ts":"2026-04-30T10:14:57.762877+00:00","stage":"ai_extracted","level":"info","message":"Pass 2/3: Claude Sonnet 4.6 retrying 12 missing fields","payload":null},{"id":265,"ts":"2026-04-30T10:15:36.650782+00:00","stage":"ai_extracted","level":"info","message":"Pass 2: Sonnet added 12 more fields","payload":null},{"id":266,"ts":"2026-04-30T10:15:36.834265+00:00","stage":"ai_extracted","level":"info","message":"Extracted 62 fields, avg confidence 82% (Opus: 50, Sonnet retry: +12)","payload":{"usage":{"input_tokens":46931,"output_tokens":7686,"cache_read_input_tokens":0,"cache_creation_input_tokens":5663},"fields":62,"passes":{"opus_full":50,"opus_retry":0,"sonnet_retry":12},"missing":0,"extra_fields":0,"avg_confidence":0.825}},{"id":267,"ts":"2026-04-30T10:15:36.847176+00:00","stage":"awaiting_review","level":"info","message":"Pipeline complete — review the extracted fields and submit when ready","payload":null},{"id":268,"ts":"2026-04-30T10:16:12.927252+00:00","stage":"submitting","level":"info","message":"Building SolarAPP+ payload from reviewed fields","payload":null},{"id":269,"ts":"2026-04-30T10:16:12.950658+00:00","stage":"submitting","level":"info","message":"Calling SolarAPP+ create_project + PATCH /details","payload":null},{"id":270,"ts":"2026-04-30T10:17:49.172818+00:00","stage":"done","level":"info","message":"SolarAPP+ draft created: https://gosolarapp.org/my-projects/4d1a158e-e76f-45d5-87aa-b56f14a8d212/edit","payload":{"project_url":"https://gosolarapp.org/my-projects/4d1a158e-e76f-45d5-87aa-b56f14a8d212/edit","project_uuid":"4d1a158e-e76f-45d5-87aa-b56f14a8d212"}}],"field_values":[{"payload_key":"Attachment points staggered","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.6,"edited":true,"reasoning":"Unirac Stronghold Butyl attachments at 48\" O.C. max on a rail system with staggered rafter attachment is standard practice; the plan shows two rows of modules with attachments distributed across the array, and staggered attachment is the default installation method for Unirac NXT Umount systems to distribute load.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Busbar #1 already present on site","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.8,"edited":true,"reasoning":"Subpanel is new (interconnection point).","source_excerpt":"(N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Busbar #1 interconnection compliance method","source":"user","raw_value":"120% rule","ai_value":"120% rule","user_value":"120% rule","confidence":0.85,"edited":true,"reasoning":"NEC 705.12(B)(2) 120% rule calculation shown.","source_excerpt":"200X1.20=240 BUS RATING x 120% 240-70=170A ALLOWABLE BACKFEED","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Busbar #1 panel type","source":"user","raw_value":"New Subpanel","ai_value":"New Subpanel","user_value":"New Subpanel","confidence":0.85,"edited":true,"reasoning":"PV interconnects at the new subpanel.","source_excerpt":"(N) 200A SUB PANEL ... PV BREAKER TIE IN SUB","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Busbar #1 rating (Amps)","source":"user","raw_value":"200","ai_value":"200","user_value":"200","confidence":0.85,"edited":true,"reasoning":"200A subpanel busbar rating.","source_excerpt":"(N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Busbar #1 subject to backfeed","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.85,"edited":true,"reasoning":"PV breaker backfeeds the subpanel busbar.","source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Current roof covering material","source":"user","raw_value":"Asphalt or composition shingles","ai_value":"Asphalt or composition shingles","user_value":"Asphalt or composition shingles","confidence":0.97,"edited":true,"reasoning":"Plan-set design criteria.","source_excerpt":"ROOFTYPE: COMP SHINGLE (MAIN HOME)","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Each ESS unit has dedicated OCPD","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.7,"edited":true,"reasoning":"Dedicated 60A breaker for the Powerwall 3.","source_excerpt":"(N) 60A BREAKER ... (N) 60A NON-FUSED AC DISCONNECT","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"ESS assembly weight (lbs)","source":"user","raw_value":"291","ai_value":"291","user_value":"291","confidence":0.9,"edited":true,"reasoning":"Tesla Powerwall 3 datasheet in the plan set explicitly states total installed weight as 291.2 lb, rounded to 291 as integer.","source_excerpt":"Total Weight of Installed Unit 132 kg (291.2 lb)","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"ESS center of mass less than 4 feet from floor","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.7,"edited":true,"reasoning":"Powerwall 3 unit dimensions are 1105mm (43.5 in) tall x 609mm wide. Wall-mounted unit with bottom near floor; even if center is at ~22 inches above mounting point, typical residential installation places center of mass well under 4 ft from floor.","source_excerpt":"TESLA POWERWALL MOUNTING BRACKET (4) 1/4\" X 3\" LAG BOLTS W/ MINIMUM 2-1/2\" EMBEDMENT (2 TOP & 2 BOTTOM) IN TO (E) STUDS","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"ESS in sleeping rooms or closets opening to sleeping rooms","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Outdoor wall installation.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"ESS installation location","source":"user","raw_value":"Outdoor walls","ai_value":"Outdoor walls","user_value":"Outdoor walls","confidence":0.85,"edited":true,"reasoning":"Wall-mounted on east outside wall per PV-7.","source_excerpt":"EAST OUTSIDE WALL ... TESLA POWERWALL MOUNTING BRACKET","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"ESS location subject to vehicle damage","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.6,"edited":true,"reasoning":"East outside wall, not in driveway path per site plan.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"ESS Model 1 includes DC-coupled expansion unit","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Only one Powerwall 3, no expansion units listed.","source_excerpt":"(N) 01- TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"ESS Model 1 Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.98,"edited":true,"reasoning":"Plan-set.","source_excerpt":"TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"ESS Model 1 Number","source":"user","raw_value":"1707000-11-J-DOM","ai_value":"1707000-11-J-DOM","user_value":"1707000-11-J-DOM","confidence":0.92,"edited":true,"reasoning":"Plan-set.","source_excerpt":"TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM)","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"ESS Model 1 Quantity","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.95,"edited":true,"reasoning":"Single Powerwall 3.","source_excerpt":"(N) 01- TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"ESS positively attached to building per manufacturer","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.95,"edited":true,"reasoning":"Plan set explicitly shows Tesla Powerwall anchoring drawing with lag bolts into wall studs per manufacturer requirements.","source_excerpt":"TESLA POWERWALL MOUNTING BRACKET (4) 1/4\" X 3\" LAG BOLTS W/ MINIMUM 2-1/2\" EMBEDMENT (2 TOP & 2 BOTTOM) IN TO (E) STUDS. USING 2 STUDS MINIMUM","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"ESS + PV Inverter certified as single unit (no field wiring)","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.85,"edited":true,"reasoning":"Powerwall 3 is integrated inverter+battery in one listed unit.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Flush mount or tilt-up","source":"user","raw_value":"Flush mount","ai_value":"Flush mount","user_value":"Flush mount","confidence":0.9,"edited":true,"reasoning":"Standard rail-flush roof mount per plan.","source_excerpt":"PHOTOVOLTAIC ROOF MOUNT SYSTEM ... NXT UMOUNT RAIL","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Home has sprinkler systems","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.5,"edited":true,"reasoning":"No mention of sprinkler systems anywhere in the plan set, Asana ticket, or BOM. McFarland, CA is a small city and this appears to be a standard single-family residential home; residential sprinkler systems are not typical for existing homes in this area unless specifically called out.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Homeowner Full Name","source":"user","raw_value":"Teresa Ramirez","ai_value":"Teresa Ramirez","user_value":"Teresa Ramirez","confidence":0.98,"edited":true,"reasoning":"Asana task name and project snapshot.","source_excerpt":"task_name: Teresa Ramirez","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Inverter 1 interconnection location","source":"user","raw_value":"New Subpanel","ai_value":"New Subpanel","user_value":"New Subpanel","confidence":0.8,"edited":true,"reasoning":"PV breaker tied into new 200A sub panel.","source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB ... (N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Inverter 1 Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.98,"edited":true,"reasoning":"Tesla Powerwall 3 integrated inverter.","source_excerpt":"TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM) INVERTER / ENERGY STORAGE SYSTEM","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Inverter 1 Model Number","source":"user","raw_value":"1707000-11-J-DOM","ai_value":"1707000-11-J-DOM","user_value":"1707000-11-J-DOM","confidence":0.95,"edited":true,"reasoning":"Plan-set system summary.","source_excerpt":"TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM)","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Inverter 1 OCPD rating (Amps)","source":"user","raw_value":"60","ai_value":"60","user_value":"60","confidence":0.95,"edited":true,"reasoning":"60A backfeed breaker on plan-set.","source_excerpt":"(N) 60A BREAKER ... 60A PV BREAKER - OK","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Inverter 1 power setting (kW)","source":"user","raw_value":"11.5","ai_value":"11.5","user_value":"11.5","confidence":0.95,"edited":true,"reasoning":"AC nameplate 11.5 kW.","source_excerpt":"SYSTEM SIZE AC: -01x 11500W= 11.500 kWAC","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Inverter architecture type","source":"user","raw_value":"String Inverter without DC-DC Converters","ai_value":"String Inverter without DC-DC Converters","user_value":"String Inverter without DC-DC Converters","confidence":0.7,"edited":true,"reasoning":"Powerwall 3 is a string-style PV inverter with MPPTs; rapid shutdown via Tesla MCI MLPE (not DC optimizers).","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Max DC PV Wire / USE-2 conductors in raceway (excl. EGC)","source":"user","raw_value":"4","ai_value":"4","user_value":"4","confidence":0.8,"edited":true,"reasoning":"Raceway 1 with 4 PV Wire conductors.","source_excerpt":"DC MCI TO JUNCTION BOX 4- 10 AWG PV WIRE","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Max DC THWN-2 conductors in raceway (excl. EGC)","source":"user","raw_value":"4","ai_value":"4","user_value":"4","confidence":0.8,"edited":true,"reasoning":"Raceway 2 has 4 THWN-2 DC conductors.","source_excerpt":"DC JUNCTION BOX TO INVERTER 4 3/4\" EMT ... 10 AWG THWN-2","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Maximum distance from module to roof (inches)","source":"user","raw_value":"10","ai_value":"10","user_value":"10","confidence":0.6,"edited":true,"reasoning":"Unirac NXT Umount with Stronghold Butyl attachment system. The plan shows conduit run '7/8\" above roof'. NXT Umount rail profile height plus module clamp typically results in module-to-roof distance of approximately 4-6 inches for the rail, but with the attachment base the total standoff is typically around 4-6 inches. However, CFC/IRC compliance for comp shingle roofs allows up to 10 inches. Without explicit dimension stated, standard NXT Umount system provides approximately 4-6 inch module clearance; using 6 as a reasonable estimate.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Maximum input DC open circuit voltage (Voc) of PV inverter","source":"user","raw_value":"600","ai_value":"600","user_value":"600","confidence":0.9,"edited":true,"reasoning":"Tesla Powerwall 3 datasheet states Withstand Voltage 600 V DC, which is the maximum input DC open circuit voltage rating.","source_excerpt":"Withstand Voltage 600 V DC\nPV DC Input Voltage Range 60 — 550 V DC","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Maximum input DC short circuit current (Isc) of PV inverter","source":"user","raw_value":"19","ai_value":"19","user_value":"19","confidence":0.85,"edited":true,"reasoning":"Tesla Powerwall 3 datasheet states Maximum Short Circuit Current per MPPT (Isc) = 19 A. This is the per-MPPT Isc rating of the inverter's DC input.","source_excerpt":"Maximum Short Circuit Current per MPPT (Isc) 19 A","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Maximum number of modules in a DC series string","source":"user","raw_value":"7","ai_value":"7","user_value":"7","confidence":0.85,"edited":true,"reasoning":"Largest string is 7 modules.","source_excerpt":"(N) 7 MODULES IN BRANCH CIRCUIT #2","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Maximum OCPD rating allowed on Inverter 1 (Amps)","source":"user","raw_value":"60","ai_value":"60","user_value":"60","confidence":0.85,"edited":true,"reasoning":"Powerwall 3 datasheet OCPD for 11.5 kW model.","source_excerpt":"Overcurrent Protection Device 60 A (11.5 kW model)","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Maximum spacing between adjacent attachment points (inches)","source":"user","raw_value":"48","ai_value":"48","user_value":"48","confidence":0.9,"edited":true,"reasoning":"Attachment max spacing on PV-2.","source_excerpt":"UNIRAC STRONGHOLD BUTYL ATTACHMENTS @ 48\" O.C MAX","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Module 1 Quantity","source":"user","raw_value":"13","ai_value":"13","user_value":"13","confidence":0.99,"edited":true,"reasoning":"13 modules.","source_excerpt":"(N) 13- QCELLS: Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Module fire rating type","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.85,"edited":true,"reasoning":"Roof type is composite shingle (explicitly stated in plan set). QCells Q.PEAK DUO BLK ML-G10+ modules on composite shingle roofs are listed as Class A (fire rating type 1) per UL 1703/UL 61730 when installed per manufacturer's instructions on standard comp shingle roofs. Class A = fire rating type 1.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Module is bifacial","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Q.PEAK DUO BLK ML-G10.C+ is monofacial.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Module Manufacturer","source":"user","raw_value":"Q CELLS","ai_value":"Q CELLS","user_value":"Q CELLS","confidence":0.95,"edited":true,"reasoning":"Hanwha Q CELLS modules.","source_excerpt":"13 - QCELLS: Q.PEAK DUO BLK ML-G10.C+ 410 (410W) MODULES","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Module Model Number","source":"user","raw_value":"Q.PEAK DUO BLK ML-G10.C+ 410","ai_value":"Q.PEAK DUO BLK ML-G10.C+ 410","user_value":"Q.PEAK DUO BLK ML-G10.C+ 410","confidence":0.95,"edited":true,"reasoning":"Plan-set system summary and BOM.","source_excerpt":"Q.PEAK DUO BLK ML-G10.C+ 410 (410W)","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Number of busbars","source":"user","raw_value":"2","ai_value":"2","user_value":"2","confidence":0.6,"edited":true,"reasoning":"MSP and new subpanel; PV interconnects at sub.","source_excerpt":"(E) 200A MAIN SERVICE PANEL ... (N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Number of composite shingle layers","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.6,"edited":true,"reasoning":"Plan set states roof type as comp shingle but does not specify number of layers. Single layer is standard for most residential roofs; no indication of re-roof over existing shingles. Default assumption is 1 layer.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Number of distinct ESS models","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.9,"edited":true,"reasoning":"Single ESS model (Powerwall 3).","source_excerpt":"01 TESLA POWERWALL 3 11.5 KW / 13.5 KWH","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"OCPD protecting busbar #1 rating (Amps)","source":"user","raw_value":"70","ai_value":"70","user_value":"70","confidence":0.6,"edited":true,"reasoning":"Subpanel fed through backup switch from 70A main breaker.","source_excerpt":"(E) 70A MAIN BREAKER ... feeds sub via backup switch","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Project Address","source":"user","raw_value":"248 Mount Arbor St, McFarland, CA 93250","ai_value":"248 Mount Arbor St, McFarland, CA 93250","user_value":"248 Mount Arbor St, McFarland, CA 93250","confidence":0.95,"edited":true,"reasoning":"From Asana custom fields Street/City/State; ZIP from PDF cover (93250).","source_excerpt":"Street: 248 Mount Arbor Street; City: McFarland; State: CA","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"PV system weight (lbs/sq ft)","source":"user","raw_value":"3.0","ai_value":"3.0","user_value":"3.0","confidence":0.55,"edited":true,"reasoning":"QCells Q.PEAK DUO BLK ML-G10+ 410W module weight is approximately 44 lbs (20 kg) per module. 13 modules x 44 lbs = 572 lbs. Array area per plan is 695.96 sq ft (new array portion). Racking (rails, clamps, attachments) adds approximately 1-1.5 lbs/sq ft. Module weight alone: 572/695.96 ≈ 0.82 lbs/sq ft + racking ~1.0 = ~1.82 lbs/sq ft. However, standard industry figure for residential PV systems is approximately 2.5-4 lbs/sq ft total. Using 3.0 as a reasonable midpoint estimate.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Racking System Manufacturer","source":"user","raw_value":"Unirac","ai_value":"Unirac","user_value":"Unirac","confidence":0.97,"edited":true,"reasoning":"BOM lists Unirac NXT UMOUNT racking.","source_excerpt":"UNIRAC NXT UMOUNT RAIL 168\"","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Racking System Model Number","source":"user","raw_value":"NXT UMOUNT","ai_value":"NXT UMOUNT","user_value":"NXT UMOUNT","confidence":0.95,"edited":true,"reasoning":"Plan-set racking model.","source_excerpt":"UNIRAC NXT UMOUNT RAIL 168\"-MILL (168RLM1-US)","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Rapid Shutdown compliance method inside array","source":"user","raw_value":"PV Hazard Control System (UL 3741)","ai_value":"PV Hazard Control System (UL 3741)","user_value":"PV Hazard Control System (UL 3741)","confidence":0.7,"edited":true,"reasoning":"Tesla MCI-2S provides UL 3741 PVRSA compliance inside array.","source_excerpt":"Certifications UL 1741 PVRSE, UL 3741, PVRSA","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Rapid Shutdown Device Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.97,"edited":true,"reasoning":"Plan-set.","source_excerpt":"05 - TESLA MCI-2S (RAPID SHUTDOWN DEVICE)","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Rapid Shutdown Device Model Number","source":"user","raw_value":"MCI-2S","ai_value":"MCI-2S","user_value":"MCI-2S","confidence":0.95,"edited":true,"reasoning":"Plan-set.","source_excerpt":"TESLA MCI-2S (RAPID SHUTDOWN DEVICE)","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Roof penetration sealant method name and description","source":"user","raw_value":"Unirac Stronghold Butyl attachment with pre-applied butyl pad (flashless, peel-and-stick)","ai_value":"Unirac Stronghold Butyl attachment with pre-applied butyl pad (flashless, peel-and-stick)","user_value":"Unirac Stronghold Butyl attachment with pre-applied butyl pad (flashless, peel-and-stick)","confidence":0.9,"edited":true,"reasoning":"Stronghold Butyl with integrated butyl seal per attachment detail.","source_excerpt":"UNIRAC STRONGHOLD BUTYL ATTACHMENTS @ 48\" O.C MAX","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Roof pitch","source":"user","raw_value":"4/12","ai_value":"4/12","user_value":"4/12","confidence":0.7,"edited":true,"reasoning":"18° tilt ≈ 3.9/12; rounded to 4/12.","source_excerpt":"ROOFTILT 18°","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Separation between ESS units less than 3 feet","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.8,"edited":true,"reasoning":"Single unit; spacing note on plans confirms ≥3'.","source_excerpt":"MULTIPLE ESS SYSTEMS SHALL BE SEPARATED FROM EACH OTHER BY AT LEAST 3'","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Smoke/heat alarm present at ESS location","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.6,"edited":true,"reasoning":"California Fire Code and CRC R328 requirements for ESS installations require smoke/heat detection at the ESS location. The plan references CRC R328.4 compliance. For a permitted installation in CA, smoke/heat alarm at ESS location would be required and assumed to be present/installed.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Supply side connection per NEC 705.12(A)","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Load-side breaker interconnection, not supply-side.","source_excerpt":"PV BREAKER TIE IN SUB ... 60A PV BREAKER","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"THWN-2 conductors in PV inverter AC output circuit raceway (excl. EGC)","source":"user","raw_value":"3","ai_value":"3","user_value":"3","confidence":0.85,"edited":true,"reasoning":"Raceway 3 has 3 THWN-2 conductors per electrical table.","source_excerpt":"AC INVERTER TO AC DISCONNECT 3 3/4\" EMT ... 6 AWG THWN-2","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Total roof area (sq ft)","source":"user","raw_value":"1884","ai_value":"1884","user_value":"1884","confidence":0.85,"edited":true,"reasoning":"Plan view roof area from PV-2 array calc table.","source_excerpt":"AREA OF ROOF (PLAN VIEW) (Sq. Ft.) 1883.98","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Using Power Control System to curtail Inverter 1","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.6,"edited":true,"reasoning":"No mention of PCS/curtailment in plans.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Utility available fault current greater than 10 kA at service","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.6,"edited":true,"reasoning":"Typical residential service; no indication >10kA.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"},{"payload_key":"Utility service feed rating (Amps)","source":"user","raw_value":"200","ai_value":"200","user_value":"200","confidence":0.95,"edited":true,"reasoning":"Existing 200A MSP.","source_excerpt":"(E) 200A MAIN SERVICE PANEL WITH (E) 70A MAIN BREAKER","in_field_map":true,"updated_at":"2026-04-30T10:16:12.782885+00:00"}],"artifacts":[{"id":57,"kind":"asana_json","local_path":"/data/runs/01KQEY2BDDRYYRNFN0HKGTTDNV/asana.json","drive_file_id":null,"sha256":null,"bytes":39033,"downloaded_at":"2026-04-30T10:13:35.878034+00:00"},{"id":58,"kind":"pdf","local_path":"/data/runs/01KQEY2BDDRYYRNFN0HKGTTDNV/pdf/Teresa_Ramirez_V0_12-16-2025.pdf","drive_file_id":"1p3daAjfHODTGPqqvHtAIAmWQWNu83s9U","sha256":"41acb4f7fafc1047d3c43daf7d286d6f6f49b9f0cfa950d693b252711d0faac4","bytes":8555492,"downloaded_at":"2026-04-30T10:13:39.268035+00:00"},{"id":59,"kind":"extraction","local_path":"/data/runs/01KQEY2BDDRYYRNFN0HKGTTDNV/extraction.json","drive_file_id":null,"sha256":null,"bytes":34149,"downloaded_at":"2026-04-30T10:15:36.665985+00:00"}],"has_final_patch":false,"final_patch_field_count":0,"_meta":{"collected_at":"2026-05-06T22:21:24.972455+00:00","iteration_count":0,"audit_log_count":18,"field_values_count":62,"artifacts_count":3,"has_final_patch":false}}