{"run":{"id":"01KQEWKMP375FGYDM96A3R6KHP","asana_task_gid":"1211709017140700","asana_task_url":"https://app.asana.com/1/1203754389657527/project/1211039529104749/task/1211709017140700","asana_task_title":"Teresa Ramirez","customer_name":"Teresa Ramirez","status":"awaiting_review","current_stage":"awaiting_review","drive_folder_id":"1lcO5aA-VkQ3sJlAZh7r_jXH5laQHAcX_","drive_cad_folder_id":"1QSubAYKQtku-FjHGZL0Y7rTqCilfizul","plan_set_filename":"Teresa Ramirez_V0_12-16-2025.pdf","bom_filename":null,"solarapp_uuid":null,"project_url":null,"error_stage":"/api/v1/projects/ef42a23e-db60-4478-a877-ed422a3da01e/details","error_message":"HTTP 422 | code=0002 | path=/api/v1/projects/ef42a23e-db60-4478-a877-ed422a3da01e/details | We could not process your request due to invalid data.","error_payload":{"errors":{"racking.sealant.datasheet":"File upload not found."},"status":422,"request_path":"/api/v1/projects/ef42a23e-db60-4478-a877-ed422a3da01e/details","solarapp_code":"0002"},"ai_token_usage":{"input_tokens":46920,"output_tokens":6581,"cache_read_input_tokens":0,"cache_creation_input_tokens":5663},"avg_confidence":0.835,"warnings":["Roof pitch derived from 18° tilt (≈4/12).","Powerwall 3 architecture treated as string inverter; MCIs are RSD devices not DC-DC optimizers.","Number of busbars set to 2 (existing MSP + new 200A subpanel); reviewer should verify which busbar requires backfeed compliance — interconnection is on the new 200A sub.","Composite shingle layers assumed 1; not stated on plans.","Module-to-roof distance estimated at 4\" for NXT Umount flush mount; verify.","BOM CSV was empty; all equipment data sourced from plan-set PDF and embedded datasheets.","Module fire rating type inferred as Class A (type 1) based on comp shingle roof type and standard QCELLS module certification — reviewer should confirm against module spec sheet.","PV system weight (lbs/sq ft) is estimated from typical module weight and racking; plan set does not state this explicitly — reviewer should verify against actual module datasheet weight.","Home has sprinkler systems is highly uncertain (confidence 0.45); no direct evidence either way in any source.","Attachment points staggered: plan set shows linear 48\" O.C. attachment pattern with no stagger detail — reviewer should confirm from installation photos or racking layout.","ESS Isc per inverter is per-MPPT; the inverter has 6 MPPTs total per datasheet.","Utility fault current >10 kA is inferred from SCE service characteristics and equipment ratings; no explicit statement in plan set."],"flow":"v1","iteration_count":0,"iteration_outcome":null,"final_diagnosis":null,"created_at":"2026-04-30T09:48:04.700416+00:00","updated_at":"2026-04-30T09:53:05.219517+00:00","submitted_at":"2026-04-30T09:51:22.484252+00:00","completed_at":null},"iterations":[],"insights":{"stuck_rules":[],"newly_revealed":[],"conditional_triggers":{}},"audit_log":[{"id":235,"ts":"2026-04-30T09:48:04.713397+00:00","stage":"asana_fetched","level":"info","message":"Resolving Asana task reference 'https://app.asana.com/1/1203754389657527/project/1211039529104749/task/1211709017140700'","payload":null},{"id":236,"ts":"2026-04-30T09:48:05.252336+00:00","stage":"asana_fetched","level":"info","message":"Loaded Asana task: Teresa Ramirez","payload":{"gid":"1211709017140700","title":"Teresa Ramirez","customer":"Teresa Ramirez"}},{"id":237,"ts":"2026-04-30T09:48:05.259286+00:00","stage":"drive_resolved","level":"info","message":"Searching Asana fields for Google Drive URL","payload":null},{"id":238,"ts":"2026-04-30T09:48:06.971640+00:00","stage":"drive_resolved","level":"info","message":"Resolved Drive folder (8 items, 7 in CAD/)","payload":{"folder_id":"1lcO5aA-VkQ3sJlAZh7r_jXH5laQHAcX_","cad_folder_id":"1QSubAYKQtku-FjHGZL0Y7rTqCilfizul"}},{"id":239,"ts":"2026-04-30T09:48:06.978324+00:00","stage":"pdf_downloaded","level":"info","message":"Picking the latest-dated plan-set PDF","payload":null},{"id":240,"ts":"2026-04-30T09:48:08.938710+00:00","stage":"pdf_downloaded","level":"info","message":"Downloaded plan-set: Teresa Ramirez_V0_12-16-2025.pdf (8.2 MB)","payload":{"bytes":8555492,"filename":"Teresa Ramirez_V0_12-16-2025.pdf"}},{"id":241,"ts":"2026-04-30T09:48:08.953209+00:00","stage":"bom_downloaded","level":"info","message":"Looking for the BOM CSV in the same folder","payload":null},{"id":242,"ts":"2026-04-30T09:48:08.970468+00:00","stage":"bom_downloaded","level":"warn","message":"No BOM CSV in folder — modules section will rely on PDF + Asana only","payload":null},{"id":243,"ts":"2026-04-30T09:48:08.978596+00:00","stage":"ai_extracted","level":"info","message":"Extracting text from the plan-set PDF","payload":null},{"id":244,"ts":"2026-04-30T09:48:14.955160+00:00","stage":"ai_extracted","level":"info","message":"Pass 1/3: Claude Opus 4.7 (full extraction)","payload":null},{"id":245,"ts":"2026-04-30T09:49:17.195289+00:00","stage":"ai_extracted","level":"info","message":"Pass 1: Opus filled 51 fields (avg 86%)","payload":null},{"id":246,"ts":"2026-04-30T09:49:17.210123+00:00","stage":"ai_extracted","level":"info","message":"Pass 2/3: Claude Sonnet 4.6 retrying 11 missing fields","payload":null},{"id":247,"ts":"2026-04-30T09:49:52.498126+00:00","stage":"ai_extracted","level":"info","message":"Pass 2: Sonnet added 11 more fields","payload":null},{"id":248,"ts":"2026-04-30T09:49:52.668833+00:00","stage":"ai_extracted","level":"info","message":"Extracted 62 fields, avg confidence 83% (Opus: 51, Sonnet retry: +11)","payload":{"usage":{"input_tokens":46920,"output_tokens":6581,"cache_read_input_tokens":0,"cache_creation_input_tokens":5663},"fields":62,"passes":{"opus_full":51,"opus_retry":0,"sonnet_retry":11},"missing":0,"extra_fields":0,"avg_confidence":0.835}},{"id":249,"ts":"2026-04-30T09:49:52.683603+00:00","stage":"awaiting_review","level":"info","message":"Pipeline complete — review the extracted fields and submit when ready","payload":null},{"id":250,"ts":"2026-04-30T09:51:22.623639+00:00","stage":"submitting","level":"info","message":"Building SolarAPP+ payload from reviewed fields","payload":null},{"id":251,"ts":"2026-04-30T09:51:22.651077+00:00","stage":"submitting","level":"info","message":"Calling SolarAPP+ create_project + PATCH /details","payload":null},{"id":252,"ts":"2026-04-30T09:53:05.226053+00:00","stage":"submitting","level":"error","message":"SolarAPP+ rejected the submission: HTTP 422 | code=0002 | path=/api/v1/projects/ef42a23e-db60-4478-a877-ed422a3da01e/details | We could not process your request due to invalid data.","payload":null}],"field_values":[{"payload_key":"Attachment points staggered","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.55,"edited":true,"reasoning":"The plan set specifies UNIRAC STRONGHOLD BUTYL attachments at 48\" O.C. MAX on a single rail run with no mention of staggered rows. The attachment detail shows a straightforward linear layout with no stagger pattern indicated. Inferred as not staggered, but reviewer should verify.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Busbar #1 already present on site","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Busbar #1 interconnection compliance method","source":"user","raw_value":"120% rule","ai_value":"120% rule","user_value":"120% rule","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"200X1.20=240 BUS RATING x 120% ... 240-70=170A ALLOWABLE BACKFEED","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Busbar #1 panel type","source":"user","raw_value":"Main Service Panel","ai_value":"Main Service Panel","user_value":"Main Service Panel","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Busbar #1 rating (Amps)","source":"user","raw_value":"200","ai_value":"200","user_value":"200","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Busbar #1 subject to backfeed","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"BACKFEED BREAKER SIZING ... 60A PV BREAKER","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Current roof covering material","source":"user","raw_value":"Asphalt or composition shingles","ai_value":"Asphalt or composition shingles","user_value":"Asphalt or composition shingles","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"ROOF TYPE: COMP SHINGLE (MAIN HOME)","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Each ESS unit has dedicated OCPD","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.85,"edited":true,"reasoning":"The plan set shows a dedicated 60A breaker for the Tesla Powerwall 3 inverter/ESS system, consistent with the datasheet's OCPD requirement. The system has its own dedicated overcurrent protection.","source_excerpt":"Overcurrent Protection Device 30 A 40 A 60 A 60 A ... (N) 60A NON-FUSED AC DISCONNECT ... 60A PV BREAKER - OK","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"ESS assembly weight (lbs)","source":"user","raw_value":"291","ai_value":"291","user_value":"291","confidence":0.9,"edited":true,"reasoning":"Tesla Powerwall 3 datasheet in the plan set states total installed unit weight is 291.2 lb, rounded to 291 as integer.","source_excerpt":"Total Weight of Installed Unit 132 kg (291.2 lb)","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"ESS center of mass less than 4 feet from floor","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.72,"edited":true,"reasoning":"The Powerwall 3 is 1105mm (43.5 in) tall. When wall-mounted with bottom near floor, the center of mass would be at approximately 21.75 in (~1.8 ft) above the bottom, well under 4 ft. Even floor-mounted, the unit's center of mass is below 4 ft.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"ESS in sleeping rooms or closets opening to sleeping rooms","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"ESS EQUIPMENT SHALL BE LOCATED 3' FROM ALL DOORS AND WINDOWS","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"ESS installation location","source":"user","raw_value":"Outdoor walls","ai_value":"Outdoor walls","user_value":"Outdoor walls","confidence":0.8,"edited":true,"reasoning":null,"source_excerpt":"EAST OUTSIDE WALL ... TESLA POWERWALL","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"ESS location subject to vehicle damage","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.6,"edited":true,"reasoning":null,"source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"ESS Model 1 includes DC-coupled expansion unit","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"(N) 01- TESLA POWERWALL 3 (no expansion mentioned)","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"ESS Model 1 Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"ESS Model 1 Number","source":"user","raw_value":"1707000-11-J-DOM","ai_value":"1707000-11-J-DOM","user_value":"1707000-11-J-DOM","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM)","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"ESS Model 1 Quantity","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"(N) 01- TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"ESS positively attached to building per manufacturer","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"(4) 1/4\" X 3\" LAG BOLTS W/ MINIMUM 2-1/2\" EMBEDMENT ... USING 2 STUDS MINIMUM","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"ESS + PV Inverter certified as single unit (no field wiring)","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"TESLA POWERWALL 3 ... INVERTER / ENERGY STORAGE SYSTEM","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Flush mount or tilt-up","source":"user","raw_value":"Flush mount","ai_value":"Flush mount","user_value":"Flush mount","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"PHOTOVOLTAIC ROOF MOUNT SYSTEM","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Home has sprinkler systems","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.45,"edited":true,"reasoning":"No mention of sprinkler systems anywhere in the Asana task, plan-set PDF, or BOM. For a single-family residential home in McFarland, CA (small city), residential sprinklers are not commonly required for existing homes. Confidence is low; reviewer should verify.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Homeowner Full Name","source":"user","raw_value":"Teresa Ramirez","ai_value":"Teresa Ramirez","user_value":"Teresa Ramirez","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"task_name: Teresa Ramirez","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Inverter 1 interconnection location","source":"user","raw_value":"New Subpanel","ai_value":"New Subpanel","user_value":"New Subpanel","confidence":0.8,"edited":true,"reasoning":null,"source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB ... (N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Inverter 1 Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM) INVERTER / ENERGY STORAGE SYSTEM","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Inverter 1 Model Number","source":"user","raw_value":"1707000-11-J-DOM","ai_value":"1707000-11-J-DOM","user_value":"1707000-11-J-DOM","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"TESLA POWERWALL 3 11.5 KW / 13.5 KWH (1707000-11-J-DOM)","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Inverter 1 OCPD rating (Amps)","source":"user","raw_value":"60","ai_value":"60","user_value":"60","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"(N) 60A BREAKER ... 60A PV BREAKER - OK","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Inverter 1 power setting (kW)","source":"user","raw_value":"11.5","ai_value":"11.5","user_value":"11.5","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"SYSTEM SIZE AC: -01x 11500W= 11.500 kWAC","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Inverter architecture type","source":"user","raw_value":"String Inverter without DC-DC Converters","ai_value":"String Inverter without DC-DC Converters","user_value":"String Inverter without DC-DC Converters","confidence":0.7,"edited":true,"reasoning":"Powerwall 3 is a string inverter with integrated MPPTs; MCIs are RSD only, not DC-DC optimizers.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Max DC PV Wire / USE-2 conductors in raceway (excl. EGC)","source":"user","raw_value":"4","ai_value":"4","user_value":"4","confidence":0.8,"edited":true,"reasoning":null,"source_excerpt":"DC MCI TO JUNCTION BOX 4- 10 AWG PV WIRE","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Max DC THWN-2 conductors in raceway (excl. EGC)","source":"user","raw_value":"4","ai_value":"4","user_value":"4","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"DC JUNCTION BOX TO INVERTER 4 ... 10 AWG THWN-2 COPPER","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Maximum distance from module to roof (inches)","source":"user","raw_value":"4","ai_value":"4","user_value":"4","confidence":0.5,"edited":true,"reasoning":"Typical flush mount standoff with NXT Umount rail; not explicitly stated.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Maximum input DC open circuit voltage (Voc) of PV inverter","source":"user","raw_value":"600.0","ai_value":"600.0","user_value":"600.0","confidence":0.88,"edited":true,"reasoning":"Tesla Powerwall 3 datasheet states Withstand Voltage 600 V DC, which represents the maximum DC open circuit voltage the inverter can accept. The input voltage range tops at 550 V DC for MPPT but withstand/max OCV is 600 V DC.","source_excerpt":"Withstand Voltage 600 V DC ... PV DC Input Voltage Range 60 — 550 V DC","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Maximum input DC short circuit current (Isc) of PV inverter","source":"user","raw_value":"19.0","ai_value":"19.0","user_value":"19.0","confidence":0.85,"edited":true,"reasoning":"Tesla Powerwall 3 datasheet specifies Maximum Short Circuit Current per MPPT (Isc) = 19 A. This is the per-MPPT Isc rating of the inverter's DC input.","source_excerpt":"Maximum Short Circuit Current per MPPT (Isc) 19 A","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Maximum number of modules in a DC series string","source":"user","raw_value":"7","ai_value":"7","user_value":"7","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"(N) 7 MODULES IN BRANCH CIRCUIT #2","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Maximum OCPD rating allowed on Inverter 1 (Amps)","source":"user","raw_value":"60","ai_value":"60","user_value":"60","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"Overcurrent Protection Device 60 A (for 11.5 kW model)","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Maximum spacing between adjacent attachment points (inches)","source":"user","raw_value":"48","ai_value":"48","user_value":"48","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"STRONGHOLD BUTYL ATTACHMENTS @ 48\" O.C MAX","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Module 1 Quantity","source":"user","raw_value":"13","ai_value":"13","user_value":"13","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"(N) 13- QCELLS: Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Module fire rating type","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.85,"edited":true,"reasoning":"Roof type is composite shingle (comp shingle). QCELLS Q.PEAK DUO BLK ML-G10+ modules on comp shingle roofs are typically rated Class A (fire rating type 1) per UL 1703/UL 61730. This is the standard fire class for residential PV modules on comp shingle roofs in California.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Module is bifacial","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Q.PEAK DUO BLK ML-G10.C+ is monofacial all-black module.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Module Manufacturer","source":"user","raw_value":"Q Cells","ai_value":"Q Cells","user_value":"Q Cells","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"QCELLS: Q.PEAK DUO BLK ML-G10.C+ 410 (410W) MODULES","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Module Model Number","source":"user","raw_value":"Q.PEAK DUO BLK ML-G10.C+ 410","ai_value":"Q.PEAK DUO BLK ML-G10.C+ 410","user_value":"Q.PEAK DUO BLK ML-G10.C+ 410","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"QCELLS: Q.PEAK DUO BLK ML-G10.C+ 410 (410W) MODULES","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Number of busbars","source":"user","raw_value":"2","ai_value":"2","user_value":"2","confidence":0.7,"edited":true,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL ... (N) 200A SUB PANEL","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Number of composite shingle layers","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.5,"edited":true,"reasoning":"Not stated; standard single-layer assumption.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Number of distinct ESS models","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"(N) 01- TESLA POWERWALL 3","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"OCPD protecting busbar #1 rating (Amps)","source":"user","raw_value":"70","ai_value":"70","user_value":"70","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"(E) 70A MAIN BREAKER","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Project Address","source":"user","raw_value":"248 Mount Arbor St, McFarland, CA 93250","ai_value":"248 Mount Arbor St, McFarland, CA 93250","user_value":"248 Mount Arbor St, McFarland, CA 93250","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"Street: 248 Mount Arbor Street, City: McFarland, State: CA","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"PV system weight (lbs/sq ft)","source":"user","raw_value":"4.0","ai_value":"4.0","user_value":"4.0","confidence":0.55,"edited":true,"reasoning":"QCELLS Q.PEAK DUO BLK ML-G10+ 410W module weighs approximately 44 lbs (20 kg) and measures ~70x44 inches (~21.4 sq ft). Module weight per sq ft ≈ 2.06 lb/sq ft. With Unirac NXT Umount racking (rails + attachments) adding ~1.5-2 lb/sq ft, total system weight is approximately 3.5-4.5 lb/sq ft. 4.0 lb/sq ft is a reasonable mid-range estimate; reviewer should verify against module spec sheet.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Racking System Manufacturer","source":"user","raw_value":"Unirac","ai_value":"Unirac","user_value":"Unirac","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"UNIRAC NXT UMOUNT RAIL 168\"-MILL (168RLM1-US)","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Racking System Model Number","source":"user","raw_value":"NXT UMOUNT","ai_value":"NXT UMOUNT","user_value":"NXT UMOUNT","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"UNIRAC NXT UMOUNT RAIL 168\"-MILL","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Rapid Shutdown compliance method inside array","source":"user","raw_value":"PV array equipped with module-level rapid shutdown via Tesla MCI-2S Mid-Circuit Interrupters (UL PVRSE/PVRSA)","ai_value":"PV array equipped with module-level rapid shutdown via Tesla MCI-2S Mid-Circuit Interrupters (UL PVRSE/PVRSA)","user_value":"PV array equipped with module-level rapid shutdown via Tesla MCI-2S Mid-Circuit Interrupters (UL PVRSE/PVRSA)","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN ... TESLA MCI EVERY 3RD MODULE","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Rapid Shutdown Device Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"TESLA MCI-2S (RAPID SHUTDOWN DEVICE)","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Rapid Shutdown Device Model Number","source":"user","raw_value":"MCI-2S","ai_value":"MCI-2S","user_value":"MCI-2S","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"TESLA MCI-2S (RAPID SHUTDOWN DEVICE)","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Roof penetration sealant method name and description","source":"user","raw_value":"Unirac Stronghold Butyl attachment with pre-applied butyl pad (flashless)","ai_value":"Unirac Stronghold Butyl attachment with pre-applied butyl pad (flashless)","user_value":"Unirac Stronghold Butyl attachment with pre-applied butyl pad (flashless)","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"UNIRAC STRONGHOLD BUTYL ATTACHMENTS @ 48\" O.C MAX","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Roof pitch","source":"user","raw_value":"4/12","ai_value":"4/12","user_value":"4/12","confidence":0.7,"edited":true,"reasoning":"18 degrees ≈ 3.9/12, rounded to 4/12","source_excerpt":"ROOF TILT 18°","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Separation between ESS units less than 3 feet","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"MULTIPLE ESS SYSTEMS SHALL BE SEPARATED FROM EACH OTHER BY AT LEAST 3'","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Smoke/heat alarm present at ESS location","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.6,"edited":true,"reasoning":"California Fire Code and CRC R328 requirements for ESS installations generally require smoke/heat detection at ESS locations. The plan set references CFC 1207 and CRC R328.4 compliance for the ESS. While not explicitly stated, compliance with these codes implies smoke/heat alarm presence.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Supply side connection per NEC 705.12(A)","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"INTERCONNECTION: PV BREAKER TIE IN SUB","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"THWN-2 conductors in PV inverter AC output circuit raceway (excl. EGC)","source":"user","raw_value":"3","ai_value":"3","user_value":"3","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"INVERTER TO AC DISCONNECT 3 ... 6 AWG THWN-2 COPPER","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Total roof area (sq ft)","source":"user","raw_value":"1884","ai_value":"1884","user_value":"1884","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"AREA OF ROOF (PLAN VIEW) (Sq. Ft.) 1883.98","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Using Power Control System to curtail Inverter 1","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.6,"edited":true,"reasoning":null,"source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Utility available fault current greater than 10 kA at service","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.65,"edited":true,"reasoning":"SCE (Southern California Edison) is the utility. For residential services in CA served by SCE, available fault current at the service entrance typically exceeds 10 kA. The Tesla Backup Switch is rated for 22 kA maximum supply short circuit current, suggesting the design anticipates fault currents potentially above 10 kA. The Powerwall 3 also lists Maximum Short-Circuit Current Rating of 10 kA.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"},{"payload_key":"Utility service feed rating (Amps)","source":"user","raw_value":"200","ai_value":"200","user_value":"200","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL WITH (E) 70A MAIN BREAKER","in_field_map":true,"updated_at":"2026-04-30T09:51:22.484252+00:00"}],"artifacts":[{"id":54,"kind":"asana_json","local_path":"/data/runs/01KQEWKMP375FGYDM96A3R6KHP/asana.json","drive_file_id":null,"sha256":null,"bytes":39033,"downloaded_at":"2026-04-30T09:48:05.238534+00:00"},{"id":55,"kind":"pdf","local_path":"/data/runs/01KQEWKMP375FGYDM96A3R6KHP/pdf/Teresa_Ramirez_V0_12-16-2025.pdf","drive_file_id":"1p3daAjfHODTGPqqvHtAIAmWQWNu83s9U","sha256":"41acb4f7fafc1047d3c43daf7d286d6f6f49b9f0cfa950d693b252711d0faac4","bytes":8555492,"downloaded_at":"2026-04-30T09:48:08.922108+00:00"},{"id":56,"kind":"extraction","local_path":"/data/runs/01KQEWKMP375FGYDM96A3R6KHP/extraction.json","drive_file_id":null,"sha256":null,"bytes":29807,"downloaded_at":"2026-04-30T09:49:52.512902+00:00"}],"has_final_patch":false,"final_patch_field_count":0,"_meta":{"collected_at":"2026-05-06T22:20:34.119667+00:00","iteration_count":0,"audit_log_count":18,"field_values_count":62,"artifacts_count":3,"has_final_patch":false}}