{"run":{"id":"01KQD5V3E6B92EG5CT2N439FK2","asana_task_gid":"1214110043322784","asana_task_url":"https://app.asana.com/1/1203754389657527/project/1207873459369363/task/1214110043322784","asana_task_title":"Minerva Marin","customer_name":"Minerva Marin","status":"awaiting_review","current_stage":"awaiting_review","drive_folder_id":"1r8Us58rgBp_yvLT1KNYw7-8lNmeUD3RH","drive_cad_folder_id":"117Qxwgs2CaX6suHiFjUvxOanq_ysFm3Q","plan_set_filename":"PVOnlyREV1MinervaMarinLIS5657704-23-2026%20(JTT%20stamped).pdf","bom_filename":null,"solarapp_uuid":null,"project_url":null,"error_stage":"eligibility","error_message":"SolarAPP+ reports address ineligible: no registered jurisdiction for this address","error_payload":{},"ai_token_usage":{"input_tokens":97445,"output_tokens":5447,"cache_read_input_tokens":5372,"cache_creation_input_tokens":0},"avg_confidence":0.868,"warnings":["BOM was empty; equipment details pulled from plan-set cover and Asana custom fields.","Roof pitch inferred from degrees (14-15°) on plan set; verify before submission.","Racking model number guessed from rail SKU 232-10095-USA (SnapNrack Ultra Rail).","Battery scope is 'No storage' per Asana, so ESS fields are omitted.","No battery (ESS) is present on this project. Asana notes state 'No storage' and Battery fields are blank. All ESS-specific fields were skipped per the only-emit-if: has_battery condition.","This is a microinverter (Enphase IQ8HC) system — there are no DC series strings longer than 1 module and no shared DC raceway conductors.","Max DC PV Wire/USE-2 and Max DC THWN-2 in raceway are both 0 because all raceway runs are AC in a microinverter system.","PV system weight lbs/sq ft is inferred from typical Qcells module weight (~44 lbs) and SnapNRack racking — operator should verify against actual module/racking datasheets.","Number of composite shingle layers defaults to 1; no double-layer or re-roof language found in any source.","Rapid shutdown compliance method is the Enphase MLPE/microinverter-based system per CEC 690.12; the exact SolarAPP+ catalog string for this field may differ — operator should confirm allowed values.","Utility fault current >10 kA is inferred from SCE urban service characteristics; operator should confirm with utility or electrical calculations sheet if an explicit value exists.","No battery/ESS in this project — Asana notes explicitly say 'Non-PV scope of work sold: No storage' and battery fields in Asana are empty. All ESS-only-emit-if=has_battery keys skipped."],"flow":"v1","iteration_count":0,"iteration_outcome":null,"final_diagnosis":null,"created_at":"2026-04-29T17:50:57.482678+00:00","updated_at":"2026-04-29T17:53:12.634226+00:00","submitted_at":"2026-04-29T17:53:08.373956+00:00","completed_at":null},"iterations":[],"insights":{"stuck_rules":[],"newly_revealed":[],"conditional_triggers":{}},"audit_log":[{"id":150,"ts":"2026-04-29T17:50:57.494569+00:00","stage":"asana_fetched","level":"info","message":"Resolving Asana task reference 'https://app.asana.com/1/1203754389657527/project/1208103004469323/task/1214110043322784?focus=true'","payload":null},{"id":151,"ts":"2026-04-29T17:50:57.897103+00:00","stage":"asana_fetched","level":"info","message":"Loaded Asana task: Minerva Marin","payload":{"gid":"1214110043322784","title":"Minerva Marin","customer":"Minerva Marin"}},{"id":152,"ts":"2026-04-29T17:50:57.903884+00:00","stage":"drive_resolved","level":"info","message":"Searching Asana fields for Google Drive URL","payload":null},{"id":153,"ts":"2026-04-29T17:50:59.256402+00:00","stage":"drive_resolved","level":"info","message":"Resolved Drive folder (4 items, 1 in CAD/)","payload":{"folder_id":"1r8Us58rgBp_yvLT1KNYw7-8lNmeUD3RH","cad_folder_id":"117Qxwgs2CaX6suHiFjUvxOanq_ysFm3Q"}},{"id":154,"ts":"2026-04-29T17:50:59.265020+00:00","stage":"pdf_downloaded","level":"info","message":"Picking the latest-dated plan-set PDF","payload":null},{"id":155,"ts":"2026-04-29T17:51:12.926236+00:00","stage":"pdf_downloaded","level":"info","message":"Downloaded plan-set: PVOnlyREV1MinervaMarinLIS5657704-23-2026%20(JTT%20stamped).pdf (27.6 MB)","payload":{"bytes":28937680,"filename":"PVOnlyREV1MinervaMarinLIS5657704-23-2026%20(JTT%20stamped).pdf"}},{"id":156,"ts":"2026-04-29T17:51:12.933693+00:00","stage":"bom_downloaded","level":"info","message":"Looking for the BOM CSV in the same folder","payload":null},{"id":157,"ts":"2026-04-29T17:51:12.948861+00:00","stage":"bom_downloaded","level":"warn","message":"No BOM CSV in folder — modules section will rely on PDF + Asana only","payload":null},{"id":158,"ts":"2026-04-29T17:51:12.960716+00:00","stage":"ai_extracted","level":"info","message":"Extracting text from the plan-set PDF","payload":null},{"id":159,"ts":"2026-04-29T17:51:14.513293+00:00","stage":"ai_extracted","level":"info","message":"Pass 1/3: Claude Opus 4.7 (full extraction)","payload":null},{"id":160,"ts":"2026-04-29T17:51:50.624142+00:00","stage":"ai_extracted","level":"info","message":"Pass 1: Opus filled 30 fields (avg 90%)","payload":null},{"id":161,"ts":"2026-04-29T17:51:50.640762+00:00","stage":"ai_extracted","level":"info","message":"Pass 2/3: Claude Sonnet 4.6 retrying 30 missing fields","payload":null},{"id":162,"ts":"2026-04-29T17:52:41.400613+00:00","stage":"ai_extracted","level":"info","message":"Pass 2: Sonnet added 15 more fields","payload":null},{"id":163,"ts":"2026-04-29T17:52:41.418101+00:00","stage":"ai_extracted","level":"info","message":"Pass 3/3: Claude Opus 4.7 final retry on 15 stubborn fields","payload":null},{"id":164,"ts":"2026-04-29T17:52:45.679901+00:00","stage":"ai_extracted","level":"info","message":"Extracted 45 fields, avg confidence 86% (Opus: 30, Sonnet retry: +15, 15 still unfilled)","payload":{"usage":{"input_tokens":97445,"output_tokens":5447,"cache_read_input_tokens":5372,"cache_creation_input_tokens":0},"fields":45,"passes":{"opus_full":30,"opus_retry":0,"sonnet_retry":15},"missing":15,"extra_fields":0,"avg_confidence":0.868}},{"id":165,"ts":"2026-04-29T17:52:45.699103+00:00","stage":"awaiting_review","level":"info","message":"Pipeline complete — review the extracted fields and submit when ready","payload":null},{"id":166,"ts":"2026-04-29T17:53:08.482390+00:00","stage":"submitting","level":"info","message":"Building SolarAPP+ payload from reviewed fields","payload":null},{"id":167,"ts":"2026-04-29T17:53:08.505534+00:00","stage":"submitting","level":"info","message":"Calling SolarAPP+ create_project + PATCH /details","payload":null},{"id":168,"ts":"2026-04-29T17:53:12.642661+00:00","stage":"submitting","level":"error","message":"SolarAPP+ rejected the submission: SolarAPP+ reports address ineligible: no registered jurisdiction for this address","payload":null}],"field_values":[{"payload_key":"Attachment points staggered","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"SUPPORT LOCATIONS HAVE BEEN STAGGERED AND OPTIMIZED","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Busbar #1 already present on site","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"(E) 100A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Busbar #1 rating (Amps)","source":"user","raw_value":"100","ai_value":"100","user_value":"100","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"MAIN SERVICE PANEL BUS RATING: (E) 100A","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Busbar #1 subject to backfeed","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"BBOC PCS ... PCS TO MONITOR BUSBAR AND DYNAMICALLY LIMIT SYSTEM OUTPUT","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Current roof covering material","source":"user","raw_value":"Asphalt or composition shingles","ai_value":"Asphalt or composition shingles","user_value":"Asphalt or composition shingles","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"RS-1 (SHINGLE - COMPOSITION)","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Flush mount or tilt-up","source":"user","raw_value":"Flush mount","ai_value":"Flush mount","user_value":"Flush mount","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"SNAPNRACK ULTRAFOOT RAFTER ATTACHMENT (flush rail-mounted array)","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Home has sprinkler systems","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"BUILDING EQUIPPED WITH FIRE SPRINKLERS NO","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Homeowner Full Name","source":"user","raw_value":"Minerva Marin","ai_value":"Minerva Marin","user_value":"Minerva Marin","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"Customer Name: Minerva Marin","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Inverter 1 interconnection location","source":"user","raw_value":"Main Service Panel","ai_value":"Main Service Panel","user_value":"Main Service Panel","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"INTERCONNECTION: LOAD BREAKER ... (E) 100A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Inverter 1 Manufacturer","source":"user","raw_value":"Enphase","ai_value":"Enphase","user_value":"Enphase","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"Inverter Manufacturer: Enphase","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Inverter 1 Model Number","source":"user","raw_value":"IQ8HC-72-M-DOM-US","ai_value":"IQ8HC-72-M-DOM-US","user_value":"IQ8HC-72-M-DOM-US","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"Inverter Type: IQ8HC-72-M-DOM-US (240V)","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Inverter 1 OCPD rating (Amps)","source":"user","raw_value":"40","ai_value":"40","user_value":"40","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"OCPD SIZE: 40A. PCS CONTROLLED CURRENT SETTING","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Inverter 1 power setting (kW)","source":"user","raw_value":"6.46","ai_value":"6.46","user_value":"6.46","confidence":0.9,"edited":true,"reasoning":"AC output power is 6460W = 6.46 kW, directly stated on the plan set cover and repeated throughout.","source_excerpt":"SYSTEM SIZE:6970W DC - 6460W AC (6363W CEC AC)","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Inverter architecture type","source":"user","raw_value":"Microinverters","ai_value":"Microinverters","user_value":"Microinverters","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"(N) PV MODULES W/(1) MICROINVERTER PER MODULE","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Max DC PV Wire / USE-2 conductors in raceway (excl. EGC)","source":"user","raw_value":"0","ai_value":"0","user_value":"0","confidence":0.85,"edited":true,"reasoning":"This is a microinverter system. Each module has its own microinverter so DC conductors run only within the module-to-microinverter connection (very short, not in a shared raceway). There are no DC PV Wire/USE-2 conductors in a shared raceway; all raceway conductors are AC (THWN-2, THHN). Effectively 0 DC conductors in the AC raceway.","source_excerpt":"MICRO-INVERTER SPECIFICATIONSMODELENPHASE IQ8HC-72-M-DOM-US MAX INPUT DC VOLTAGE60V","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Max DC THWN-2 conductors in raceway (excl. EGC)","source":"user","raw_value":"0","ai_value":"0","user_value":"0","confidence":0.85,"edited":true,"reasoning":"Microinverter system — no DC THWN-2 conductors in any shared raceway. THWN-2 conductors listed are AC output conductors, not DC.","source_excerpt":"CONDUCTOR SCHEDULEWIRE TAGABCDEFGHI ... 10 AWG THWN-2, CU ... CONDUITQ-CABLENM-B CABLE3/4\" EMT","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Maximum distance from module to roof (inches)","source":"user","raw_value":"6","ai_value":"6","user_value":"6","confidence":0.7,"edited":true,"reasoning":null,"source_excerpt":"MAX 6\" (gap between module and roof shown on attachment detail)","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Maximum input DC open circuit voltage (Voc) of PV inverter","source":"user","raw_value":"60.0","ai_value":"60.0","user_value":"60.0","confidence":0.95,"edited":true,"reasoning":"Directly stated in the electrical calculations sheet: Max Input DC Voltage = 60V.","source_excerpt":"MICRO-INVERTER SPECIFICATIONSMODELENPHASE IQ8HC-72-M-DOM-USMAX INPUT DC VOLTAGE60V","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Maximum input DC short circuit current (Isc) of PV inverter","source":"user","raw_value":"14.0","ai_value":"14.0","user_value":"14.0","confidence":0.95,"edited":true,"reasoning":"Directly stated in PV-6 electrical calculations: Max Input DC Current = 14A.","source_excerpt":"MICRO-INVERTER SPECIFICATIONSMODELENPHASE IQ8HC-72-M-DOM-USMAX INPUT DC CURRENT14A","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Maximum number of modules in a DC series string","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.95,"edited":true,"reasoning":"Microinverter system — each module has its own dedicated microinverter, so each string contains exactly 1 module.","source_excerpt":"(N) PV MODULES W/(1) MICROINVERTER PER MODULE","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Maximum OCPD rating allowed on Inverter 1 (Amps)","source":"user","raw_value":"20","ai_value":"20","user_value":"20","confidence":0.85,"edited":true,"reasoning":"The three-line diagram shows 20A OCPD associated with each microinverter branch circuit. The IQ8HC datasheet maximum OCPD per branch is 20A, consistent with plan set labeling.","source_excerpt":"20AAB20A** ... (N) ENPHASE IQ8HC-72-M-DOM-US [240V] MICRO-INVERTER (SINGLE PHASE)","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Maximum spacing between adjacent attachment points (inches)","source":"user","raw_value":"48","ai_value":"48","user_value":"48","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"MAX ATTACHMENT SPACING SHALL NOT EXCEED 48\" O.C.","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Module 1 Quantity","source":"user","raw_value":"17","ai_value":"17","user_value":"17","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"MODULES: (17) QCELLS Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Module fire rating type","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.8,"edited":true,"reasoning":"Roof type is composition shingle (Class A rated assembly). Qcells Q.PEAK DUO BLK ML-G10.C+ is a standard residential module certified as Class A (fire rating class 1) per UL 61730 / IEC 61730 when installed on Class A rated roofing. Standard for California residential PV.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Module is bifacial","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Q.PEAK DUO BLK ML-G10.C+ 410 is a monofacial module.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Module Manufacturer","source":"user","raw_value":"Qcells","ai_value":"Qcells","user_value":"Qcells","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"Module Manufacturer: Qcells","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Module Model Number","source":"user","raw_value":"Q.PEAK DUO BLK ML-G10.C+ 410","ai_value":"Q.PEAK DUO BLK ML-G10.C+ 410","user_value":"Q.PEAK DUO BLK ML-G10.C+ 410","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"Module Type: Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Number of busbars","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"MAIN SERVICE PANEL BUS RATING: (E) 100A","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Number of composite shingle layers","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.55,"edited":true,"reasoning":"Roof described as SHINGLE - COMPOSITION across all three roof sections. No re-roofing or double-layer indicated. Single layer is the default assumption for a residential composition shingle roof with no contrary evidence.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"OCPD protecting busbar #1 rating (Amps)","source":"user","raw_value":"100","ai_value":"100","user_value":"100","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"(E) 100A MAIN BREAKER","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Project Address","source":"user","raw_value":"1132 South Cambridge Street, Anaheim, CA 92805","ai_value":"1132 South Cambridge Street, Anaheim, CA 92805","user_value":"1132 South Cambridge Street, Anaheim, CA 92805","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"Street: 1132 South Cambridge Street; City: Anaheim; State.: CA","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"PV system weight (lbs/sq ft)","source":"user","raw_value":"4.0","ai_value":"4.0","user_value":"4.0","confidence":0.5,"edited":true,"reasoning":"No explicit weight/sq ft stated. Qcells 410W module weighs ~44 lbs; SnapNRack racking adds ~2-3 lbs/sq ft. Module area: 74.0\" x 41.1\" = 21.2 sq ft. 44 lbs / 21.2 sq ft ≈ 2.1 lbs/sq ft module only; with racking ~3.5-4.5 lbs/sq ft. 4.0 lbs/sq ft is a typical mid-range estimate for this system type.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Racking System Manufacturer","source":"user","raw_value":"SnapNrack","ai_value":"SnapNrack","user_value":"SnapNrack","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"RAILS 12 SNAPNRACK 232-10095-USA","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Racking System Model Number","source":"user","raw_value":"Ultra Rail (232-10095-USA)","ai_value":"Ultra Rail (232-10095-USA)","user_value":"Ultra Rail (232-10095-USA)","confidence":0.8,"edited":true,"reasoning":null,"source_excerpt":"(N) SNAPNRACK ULTRA RAIL ... SNAPNRACK 232-10095-USA","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Rapid Shutdown compliance method inside array","source":"user","raw_value":"Module-level power electronics (MLPE) - rapid shutdown initiated, conductors de-energized within array boundary per CEC 690.12","ai_value":"Module-level power electronics (MLPE) - rapid shutdown initiated, conductors de-energized within array boundary per CEC 690.12","user_value":"Module-level power electronics (MLPE) - rapid shutdown initiated, conductors de-energized within array boundary per CEC 690.12","confidence":0.85,"edited":true,"reasoning":"Enphase IQ8 microinverters are MLPE devices that comply with CEC 690.12 rapid shutdown inside the array boundary. Each module has a microinverter that shuts down within the array when initiated.","source_excerpt":"PV SYSTEM CIRCUITS INSTALLED ON OR IN HABITABLE BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION ... CEC 690.124. SOLAR SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE \"OFF\" POSITION","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Rapid Shutdown Device Manufacturer","source":"user","raw_value":"Enphase","ai_value":"Enphase","user_value":"Enphase","confidence":0.85,"edited":true,"reasoning":"Enphase IQ8 microinverters have integrated rapid shutdown functionality per SunSpec standards. The RSD function is built into the Enphase microinverter system itself — Enphase is the RSD manufacturer.","source_excerpt":"(N) ENPHASE IQ8HC-72-M-DOM-US [240V] MICRO-INVERTER (SINGLE PHASE) ... SOLAR SYSTEM EQUIPPED WITH RAPID SHUTDOWN","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Rapid Shutdown Device Model Number","source":"user","raw_value":"IQ8HC-72-M-DOM-US","ai_value":"IQ8HC-72-M-DOM-US","user_value":"IQ8HC-72-M-DOM-US","confidence":0.8,"edited":true,"reasoning":"Enphase IQ8HC microinverters include integrated rapid shutdown compliance. The microinverter itself serves as the RSD device.","source_excerpt":"INVERTER(S): (17) ENPHASE IQ8HC-72-M-DOM-US","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Roof penetration sealant method name and description","source":"user","raw_value":"SnapNrack UltraFoot rafter attachment with sealed penetration (flashing)","ai_value":"SnapNrack UltraFoot rafter attachment with sealed penetration (flashing)","user_value":"SnapNrack UltraFoot rafter attachment with sealed penetration (flashing)","confidence":0.7,"edited":true,"reasoning":null,"source_excerpt":"SNR ULTRAFOOT RAFTER BLACK ... SEALED PENETRATION","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Roof pitch","source":"user","raw_value":"4/12","ai_value":"4/12","user_value":"4/12","confidence":0.6,"edited":true,"reasoning":"Roof slopes listed at 14-15 degrees; ~14° ≈ 3/12, ~15° ≈ 4/12. Using predominant 15° -> 4/12.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Supply side connection per NEC 705.12(A)","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"INTERCONNECTION: LOAD BREAKER","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"THWN-2 conductors in PV inverter AC output circuit raceway (excl. EGC)","source":"user","raw_value":"4","ai_value":"4","user_value":"4","confidence":0.7,"edited":true,"reasoning":"The conductor schedule shows THWN-2 conductors (tags C and D) in 3/4\" EMT. The conduit fill column references a max of 4 conductors. L1, L2, N, and EGC would be 4 total; excluding EGC = 3 current-carrying + neutral. The schedule shows 4 wires per conduit (CC WIRES PER CONDUIT/CABLE MAX = 4 for the EMT runs).","source_excerpt":"CONDUCTOR SCHEDULEWIRE TAG ... C: 10 AWG THWN-2, CU ... D: 8 AWG THWN-2, CU ... CONDUIT 3/4\" EMT ... 4","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Total roof area (sq ft)","source":"user","raw_value":"1867","ai_value":"1867","user_value":"1867","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"TOTAL ROOF SQ FT: 1867","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Using Power Control System to curtail Inverter 1","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"PCS CONTROLLED CURRENT SETTING USING BBOC PROTECTION","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Utility available fault current greater than 10 kA at service","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.65,"edited":true,"reasoning":"SCE (Southern California Edison) serving Anaheim, CA is a major utility in a dense urban/suburban area. Available fault current at residential services in SCE territory typically exceeds 10 kA. No explicit value given in the plan set but standard practice in this utility region supports Yes.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"},{"payload_key":"Utility service feed rating (Amps)","source":"user","raw_value":"100","ai_value":"100","user_value":"100","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"MAIN SERVICE DISCONNECT RATING: (E) 100A","in_field_map":true,"updated_at":"2026-04-29T17:53:08.373956+00:00"}],"artifacts":[{"id":37,"kind":"asana_json","local_path":"/data/runs/01KQD5V3E6B92EG5CT2N439FK2/asana.json","drive_file_id":null,"sha256":null,"bytes":51174,"downloaded_at":"2026-04-29T17:50:57.881998+00:00"},{"id":38,"kind":"pdf","local_path":"/data/runs/01KQD5V3E6B92EG5CT2N439FK2/pdf/PVOnlyREV1MinervaMarinLIS5657704-23-2026_20_JTT_20stamped_.pdf","drive_file_id":"1MS6Uzp5cTOdzz_QsS2qMmgjndKH4_YBV","sha256":"88737c05670a892457dbcd42b7669b40596b99727ad8897b7ca34aa7ddf6ac68","bytes":28937680,"downloaded_at":"2026-04-29T17:51:12.905022+00:00"},{"id":39,"kind":"extraction","local_path":"/data/runs/01KQD5V3E6B92EG5CT2N439FK2/extraction.json","drive_file_id":null,"sha256":null,"bytes":22084,"downloaded_at":"2026-04-29T17:52:45.531624+00:00"}],"has_final_patch":false,"final_patch_field_count":0,"_meta":{"collected_at":"2026-05-06T22:22:37.260625+00:00","iteration_count":0,"audit_log_count":19,"field_values_count":45,"artifacts_count":3,"has_final_patch":false}}