{"run":{"id":"01KQD0C34CGNYX4NFQ5TXK5PKZ","asana_task_gid":"1214181955813678","asana_task_url":"https://app.asana.com/1/1203754389657527/project/1207873459369363/task/1214181955813678","asana_task_title":"Stacey Santoro","customer_name":"Stacey Santoro","status":"done","current_stage":"done","drive_folder_id":"1jk4uZa9rWFojCP18V3vC94vhoVoOOfX4","drive_cad_folder_id":"1ozsPLPvKraYi4klp0BlZmAko4enpLDRU","plan_set_filename":"Aurora Shade Report - Stacey Santoro - LGCY Design - JobEngine PV1 - 2026-04-24 111719.pdf","bom_filename":"BOM_LIS56648.csv","solarapp_uuid":"c15a815c-1f56-4f7d-a48c-f7e4a4af7c8d","project_url":"https://gosolarapp.org/my-projects/c15a815c-1f56-4f7d-a48c-f7e4a4af7c8d/edit","error_stage":null,"error_message":null,"error_payload":null,"ai_token_usage":{"input_tokens":18306,"output_tokens":6168,"cache_read_input_tokens":0,"cache_creation_input_tokens":5372},"avg_confidence":0.742,"warnings":["Plan set provided is a shade report only; no structural/electrical details extracted. Roof pitch listed as 17° on shade report (not N/12 form) — omitted to avoid bad conversion; operator should set pitch manually (17° ≈ 4/12).","Inverter architecture guessed; Tesla Powerwall 3 integrates PV string inverter — verify selection.","Module bifacial inferred from product line (monofacial all-black).","Plan-set PDF is a shade report only — no electrical one-line, roof geometry details, or structural drawings were extracted. Most electrical and structural values were inferred from equipment specs and standard residential practices.","Roof pitch of 4/12 inferred from 17° array pitch stated in shade report (tan 17° ≈ 3.67/12 ≈ 4/12).","Tesla Powerwall 3 serves as both inverter and battery — Inverter 1 Model Number set accordingly.","ESS installation location (garage) is an inference; reviewer should confirm from site survey photos.","Total roof area is a low-confidence estimate — reviewer should verify from plan set or site survey.","MCI-2 quantity of 3 for 9 modules may indicate 3 strings of 3 modules each, but single array of 9 at same azimuth/pitch suggests one string of 9.","Battery Manufacturer in Asana is Tesla, Battery field shows 'Adders: Battery' confirming has_battery=Yes, so all ESS fields are emitted."],"flow":"v1","iteration_count":0,"iteration_outcome":null,"final_diagnosis":null,"created_at":"2026-04-29T16:15:22.788278+00:00","updated_at":"2026-04-29T16:17:50.009462+00:00","submitted_at":"2026-04-29T16:17:33.476528+00:00","completed_at":"2026-04-29T16:17:50.009462+00:00"},"iterations":[],"insights":{"stuck_rules":[],"newly_revealed":[],"conditional_triggers":{}},"audit_log":[{"id":114,"ts":"2026-04-29T16:15:22.802973+00:00","stage":"asana_fetched","level":"info","message":"Resolving Asana task reference 'https://app.asana.com/1/1203754389657527/project/1208103004469323/task/1214181955813678'","payload":null},{"id":115,"ts":"2026-04-29T16:15:23.411655+00:00","stage":"asana_fetched","level":"info","message":"Loaded Asana task: Stacey Santoro","payload":{"gid":"1214181955813678","title":"Stacey Santoro","customer":"Stacey Santoro"}},{"id":116,"ts":"2026-04-29T16:15:23.418074+00:00","stage":"drive_resolved","level":"info","message":"Searching Asana fields for Google Drive URL","payload":null},{"id":117,"ts":"2026-04-29T16:15:24.925353+00:00","stage":"drive_resolved","level":"info","message":"Resolved Drive folder (5 items, 4 in CAD/)","payload":{"folder_id":"1jk4uZa9rWFojCP18V3vC94vhoVoOOfX4","cad_folder_id":"1ozsPLPvKraYi4klp0BlZmAko4enpLDRU"}},{"id":118,"ts":"2026-04-29T16:15:24.931760+00:00","stage":"pdf_downloaded","level":"info","message":"Picking the latest-dated plan-set PDF","payload":null},{"id":119,"ts":"2026-04-29T16:15:26.907235+00:00","stage":"pdf_downloaded","level":"info","message":"Downloaded plan-set: Aurora Shade Report - Stacey Santoro - LGCY Design - JobEngine PV1 - 2026-04-24 111719.pdf (3.7 MB)","payload":{"bytes":3864987,"filename":"Aurora Shade Report - Stacey Santoro - LGCY Design - JobEngine PV1 - 2026-04-24 111719.pdf"}},{"id":120,"ts":"2026-04-29T16:15:26.915641+00:00","stage":"bom_downloaded","level":"info","message":"Looking for the BOM CSV in the same folder","payload":null},{"id":121,"ts":"2026-04-29T16:15:27.510829+00:00","stage":"bom_downloaded","level":"info","message":"Downloaded BOM: BOM_LIS56648.csv (16 rows)","payload":{"rows":16,"filename":"BOM_LIS56648.csv"}},{"id":122,"ts":"2026-04-29T16:15:27.517666+00:00","stage":"ai_extracted","level":"info","message":"Extracting text from the plan-set PDF","payload":null},{"id":123,"ts":"2026-04-29T16:15:27.730796+00:00","stage":"ai_extracted","level":"info","message":"Pass 1/3: Claude Opus 4.7 (full extraction)","payload":null},{"id":124,"ts":"2026-04-29T16:15:46.482378+00:00","stage":"ai_extracted","level":"info","message":"Pass 1: Opus filled 16 fields (avg 88%)","payload":null},{"id":125,"ts":"2026-04-29T16:15:46.495506+00:00","stage":"ai_extracted","level":"info","message":"Pass 2/3: Claude Sonnet 4.6 retrying 44 missing fields","payload":null},{"id":126,"ts":"2026-04-29T16:17:02.924280+00:00","stage":"ai_extracted","level":"info","message":"Pass 2: Sonnet added 44 more fields","payload":null},{"id":127,"ts":"2026-04-29T16:17:03.130176+00:00","stage":"ai_extracted","level":"info","message":"Extracted 60 fields, avg confidence 74% (Opus: 16, Sonnet retry: +44)","payload":{"usage":{"input_tokens":18306,"output_tokens":6168,"cache_read_input_tokens":0,"cache_creation_input_tokens":5372},"fields":60,"passes":{"opus_full":16,"opus_retry":0,"sonnet_retry":44},"missing":0,"extra_fields":0,"avg_confidence":0.742}},{"id":128,"ts":"2026-04-29T16:17:03.144772+00:00","stage":"awaiting_review","level":"info","message":"Pipeline complete — review the extracted fields and submit when ready","payload":null},{"id":129,"ts":"2026-04-29T16:17:33.624807+00:00","stage":"submitting","level":"info","message":"Building SolarAPP+ payload from reviewed fields","payload":null},{"id":130,"ts":"2026-04-29T16:17:33.650373+00:00","stage":"submitting","level":"info","message":"Calling SolarAPP+ create_project + PATCH /details","payload":null},{"id":131,"ts":"2026-04-29T16:17:50.035564+00:00","stage":"done","level":"info","message":"SolarAPP+ draft created: https://gosolarapp.org/my-projects/c15a815c-1f56-4f7d-a48c-f7e4a4af7c8d/edit","payload":{"project_url":"https://gosolarapp.org/my-projects/c15a815c-1f56-4f7d-a48c-f7e4a4af7c8d/edit","project_uuid":"c15a815c-1f56-4f7d-a48c-f7e4a4af7c8d"}}],"field_values":[{"payload_key":"Attachment points staggered","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.6,"edited":true,"reasoning":"SnapNrack UR-45 racking systems with UltraFoot attachments are standardly installed in a staggered pattern per SnapNrack installation guidelines to distribute load across rafters.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Busbar #1 already present on site","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.5,"edited":true,"reasoning":"New interconnection components (60A breaker) are listed in BOM, suggesting new hardware. No explicit mention of existing busbar on site.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Busbar #1 rating (Amps)","source":"user","raw_value":"200","ai_value":"200","user_value":"200","confidence":0.5,"edited":true,"reasoning":"Standard residential service panel in California is typically 200A. Utility service feed rating inferred as 200A for Apple Valley, CA residential.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Busbar #1 subject to backfeed","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.8,"edited":true,"reasoning":"Solar PV system with battery interconnected to main service panel via 60A breaker will subject the busbar to backfeed from the inverter/battery system.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Current roof covering material","source":"user","raw_value":"Asphalt or composition shingles","ai_value":"Asphalt or composition shingles","user_value":"Asphalt or composition shingles","confidence":0.75,"edited":true,"reasoning":"Apple Valley, CA residential homes predominantly use asphalt/composition shingles. SnapNrack UR-45 racking with lag bolt attachments is typical for comp shingle roofs. No tile or metal roof indicators found.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Each ESS unit has dedicated OCPD","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.85,"edited":true,"reasoning":"60A 2-pole breaker in BOM serves as OCPD for the ESS unit.","source_excerpt":"24232 60 Amp 2-Pole | Whole Home Backup","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"ESS assembly weight (lbs)","source":"user","raw_value":"287","ai_value":"287","user_value":"287","confidence":0.8,"edited":true,"reasoning":"Tesla Powerwall 3 published weight is approximately 287 lbs per unit. 1 unit in BOM.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"ESS center of mass less than 4 feet from floor","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.8,"edited":true,"reasoning":"Tesla Powerwall 3 is wall-mounted and its center of mass is typically below 4 feet from the floor when mounted at standard height.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"ESS in sleeping rooms or closets opening to sleeping rooms","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"ESS units are standardly installed in garages or utility areas, not sleeping rooms. No indication otherwise.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"ESS installation location","source":"user","raw_value":"Garage (interior)","ai_value":"Garage (interior)","user_value":"Garage (interior)","confidence":0.6,"edited":true,"reasoning":"Tesla Powerwall 3 is most commonly installed in garage for residential projects. No explicit location stated in documents.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"ESS location subject to vehicle damage","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.55,"edited":true,"reasoning":"If installed in garage (interior), there is potential for vehicle damage unless protected. Standard assumption for garage installations.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"ESS Model 1 includes DC-coupled expansion unit","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Tesla Powerwall 3 is an AC-coupled all-in-one unit. No DC-coupled expansion unit listed in BOM.","source_excerpt":"Tesla Powerwall 3 | af3fdaf5-421c-4977-8033-a47f0da82725 | Whole Home Backup","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"ESS Model 1 Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"Battery Manufacturer: Tesla","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"ESS Model 1 Number","source":"user","raw_value":"Powerwall 3","ai_value":"Powerwall 3","user_value":"Powerwall 3","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"ESS Model 1 Quantity","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"1 | LIS56648 | Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"ESS positively attached to building per manufacturer","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.9,"edited":true,"reasoning":"Tesla Powerwall 3 installation requirements mandate positive attachment to building structure per manufacturer specs.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"ESS + PV Inverter certified as single unit (no field wiring)","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.8,"edited":true,"reasoning":"Tesla Powerwall 3 is a single integrated PV inverter + ESS unit.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Flush mount or tilt-up","source":"user","raw_value":"Flush mount","ai_value":"Flush mount","user_value":"Flush mount","confidence":0.85,"edited":true,"reasoning":"Roof mount with SnapNrack Ultra Rail rail system implies flush mount.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Home has sprinkler systems","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.5,"edited":true,"reasoning":"No mention of sprinkler system in any documents. Residential homes in Apple Valley, CA of this vintage typically do not have sprinkler systems unless specified.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Homeowner Full Name","source":"user","raw_value":"Stacey Santoro","ai_value":"Stacey Santoro","user_value":"Stacey Santoro","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"Customer Name: Stacey Santoro","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Inverter 1 interconnection location","source":"user","raw_value":"Main Service Panel","ai_value":"Main Service Panel","user_value":"Main Service Panel","confidence":0.7,"edited":true,"reasoning":"Tesla Powerwall 3 with Backup Switch (listed in BOM) connects to main service panel for whole home backup. No subpanel mentioned.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Inverter 1 Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"Inverter Manufacturer: Tesla","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Inverter 1 Model Number","source":"user","raw_value":"Tesla Powerwall 3","ai_value":"Tesla Powerwall 3","user_value":"Tesla Powerwall 3","confidence":0.85,"edited":true,"reasoning":"Tesla Powerwall 3 is an integrated inverter+battery. The Asana notes confirm '1 x Tesla inverter (or similar)' and BOM lists Powerwall 3 as the ESS. For this system, the Powerwall 3 is the inverter.","source_excerpt":"Tesla Powerwall 3 | af3fdaf5-421c-4977-8033-a47f0da82725 | Whole Home Backup","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Inverter 1 OCPD rating (Amps)","source":"user","raw_value":"60","ai_value":"60","user_value":"60","confidence":0.85,"edited":true,"reasoning":"60A 2-pole breaker listed in BOM is the OCPD for the inverter/ESS interconnection.","source_excerpt":"24232 60 Amp 2-Pole | Whole Home Backup","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Inverter 1 power setting (kW)","source":"user","raw_value":"3.69","ai_value":"3.69","user_value":"3.69","confidence":0.9,"edited":true,"reasoning":"System size stated as 3.69 kW DC in Asana custom fields.","source_excerpt":"KW: 3.69","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Inverter architecture type","source":"user","raw_value":"String Inverter without DC-DC Converters","ai_value":"String Inverter without DC-DC Converters","user_value":"String Inverter without DC-DC Converters","confidence":0.5,"edited":true,"reasoning":"Tesla Powerwall 3 acts as integrated PV string inverter; default architecture without DC optimizers.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Max DC PV Wire / USE-2 conductors in raceway (excl. EGC)","source":"user","raw_value":"2","ai_value":"2","user_value":"2","confidence":0.6,"edited":true,"reasoning":"Single string of 9 modules with standard 2-wire (positive and negative) DC PV wire configuration.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Max DC THWN-2 conductors in raceway (excl. EGC)","source":"user","raw_value":"2","ai_value":"2","user_value":"2","confidence":0.55,"edited":true,"reasoning":"Typical single-string residential system uses 2 THWN-2 conductors (positive and negative) in the DC raceway.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Maximum distance from module to roof (inches)","source":"user","raw_value":"10","ai_value":"10","user_value":"10","confidence":0.6,"edited":true,"reasoning":"SnapNrack UR-45 with UltraFoot mounts on comp shingle roof typically results in module standoff of approximately 6-10 inches. 10 inches is conservative standard for SolarAPP+ filings.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Maximum input DC open circuit voltage (Voc) of PV inverter","source":"user","raw_value":"600","ai_value":"600","user_value":"600","confidence":0.75,"edited":true,"reasoning":"Tesla Powerwall 3 integrated inverter has a maximum DC input Voc of 600V per published specifications.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Maximum input DC short circuit current (Isc) of PV inverter","source":"user","raw_value":"15","ai_value":"15","user_value":"15","confidence":0.6,"edited":true,"reasoning":"Tesla Powerwall 3 maximum DC input Isc is approximately 15A per published specifications for the integrated MPPT inputs.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Maximum number of modules in a DC series string","source":"user","raw_value":"9","ai_value":"9","user_value":"9","confidence":0.85,"edited":true,"reasoning":"9 modules total in BOM. With a single array of 9 modules at pitch 17° per shade report, all 9 are in one string.","source_excerpt":"QCELLS Q.PEAK DUO BLK ML-G10.C+ 410 | Qty: 9","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Maximum OCPD rating allowed on Inverter 1 (Amps)","source":"user","raw_value":"60","ai_value":"60","user_value":"60","confidence":0.8,"edited":true,"reasoning":"Tesla Powerwall 3 maximum OCPD rating is 60A per its specifications, consistent with the 60A breaker in BOM.","source_excerpt":"24232 60 Amp 2-Pole | Whole Home Backup","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Maximum spacing between adjacent attachment points (inches)","source":"user","raw_value":"72","ai_value":"72","user_value":"72","confidence":0.6,"edited":true,"reasoning":"SnapNrack UR-45 system on comp shingle with UltraFoot mounts typically has maximum rafter spacing of 72 inches (6 feet) per SnapNrack engineering documentation.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Module 1 Quantity","source":"user","raw_value":"9","ai_value":"9","user_value":"9","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"9 | LIS56648 | QCELLS Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Module fire rating type","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.8,"edited":true,"reasoning":"Hanwha Q-Cells Q.PEAK DUO BLK ML-G10.C+ 410 modules are Class A (fire rating type 1) as standard for residential PV modules installed on comp shingle roofs.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Module is bifacial","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Q.PEAK DUO BLK ML-G10.C+ is a monofacial all-black module.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Module Manufacturer","source":"user","raw_value":"Hanwha Q CELLS","ai_value":"Hanwha Q CELLS","user_value":"Hanwha Q CELLS","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"Module Type: Hanwha Q-Cells Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Module Model Number","source":"user","raw_value":"Q.PEAK DUO BLK ML-G10.C+ 410","ai_value":"Q.PEAK DUO BLK ML-G10.C+ 410","user_value":"Q.PEAK DUO BLK ML-G10.C+ 410","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"Q.PEAK DUO BLK ML-G10.C+ 410 (MD06G100A-017)","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Number of busbars","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.75,"edited":true,"reasoning":"Standard single main service panel installation with one busbar for interconnection.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Number of composite shingle layers","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.6,"edited":true,"reasoning":"Standard residential re-roofing codes typically allow only one layer of comp shingles. No indication of re-roofing over existing layer.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Number of distinct ESS models","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"1 | Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"OCPD protecting busbar #1 rating (Amps)","source":"user","raw_value":"200","ai_value":"200","user_value":"200","confidence":0.55,"edited":true,"reasoning":"Standard 200A main breaker protects the main service panel busbar in typical California residential installations.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Project Address","source":"user","raw_value":"18599 Cocqui Rd, Apple Valley, CA 92307","ai_value":"18599 Cocqui Rd, Apple Valley, CA 92307","user_value":"18599 Cocqui Rd, Apple Valley, CA 92307","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"Address 18599 Cocqui Rd, Apple Valley, CA, 92307","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"PV system weight (lbs/sq ft)","source":"user","raw_value":"3.5","ai_value":"3.5","user_value":"3.5","confidence":0.6,"edited":true,"reasoning":"Typical residential PV system with SnapNrack racking and standard 60-cell modules weighs approximately 3-4 lbs/sq ft including racking. 3.5 is a standard conservative estimate.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Racking System Manufacturer","source":"user","raw_value":"SnapNrack","ai_value":"SnapNrack","user_value":"SnapNrack","confidence":0.9,"edited":true,"reasoning":null,"source_excerpt":"SnapNrack Domestic UR-45 172\" Rail - Mill, 232-10095-USA","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Racking System Model Number","source":"user","raw_value":"Ultra Rail (UR-45)","ai_value":"Ultra Rail (UR-45)","user_value":"Ultra Rail (UR-45)","confidence":0.75,"edited":true,"reasoning":null,"source_excerpt":"SnapNrack Domestic UR-45 172\" Rail","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Rapid Shutdown compliance method inside array","source":"user","raw_value":"Module-level power electronics (MLPE)","ai_value":"Module-level power electronics (MLPE)","user_value":"Module-level power electronics (MLPE)","confidence":0.7,"edited":true,"reasoning":"Tesla MCI-2 modules provide module-level communication/shutdown capability, complying with NEC 2017/2020 rapid shutdown requirements inside the array boundary via MLPE.","source_excerpt":"Tesla MCI-2 | Qty: 3 | LIS56648 | Whole Home Backup","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Rapid Shutdown Device Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.7,"edited":true,"reasoning":"Tesla Powerwall 3 has integrated rapid shutdown capability. The Tesla MCI-2 module-level communication interface listed in BOM (qty 3) facilitates rapid shutdown compliance at the module level.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Rapid Shutdown Device Model Number","source":"user","raw_value":"MCI-2","ai_value":"MCI-2","user_value":"MCI-2","confidence":0.75,"edited":true,"reasoning":"Tesla MCI-2 is listed in BOM as a communication interface for the Powerwall 3 system, which provides module-level rapid shutdown compliance.","source_excerpt":"Tesla MCI-2 | Qty: 3 | LIS56648 | Whole Home Backup","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Roof penetration sealant method name and description","source":"user","raw_value":"SnapNrack UltraFoot with EPDM butyl sealant and flashing","ai_value":"SnapNrack UltraFoot with EPDM butyl sealant and flashing","user_value":"SnapNrack UltraFoot with EPDM butyl sealant and flashing","confidence":0.6,"edited":true,"reasoning":"SnapNrack UltraFoot mounts (listed in BOM) use integrated EPDM gasket/butyl sealant with lag bolt through flashing as standard penetration sealant method for comp shingle roofs.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Roof pitch","source":"user","raw_value":"4/12","ai_value":"4/12","user_value":"4/12","confidence":0.65,"edited":true,"reasoning":"The shade report lists array pitch as 17°. Converting 17° to approximate N/12: tan(17°) ≈ 0.306, so approximately 3.67/12, which rounds to 4/12 as the closest standard pitch.","source_excerpt":"9 135° 17° 94% 98% 92%","in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Separation between ESS units less than 3 feet","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.7,"edited":true,"reasoning":"Only 1 Tesla Powerwall 3 unit in BOM, so separation between units is not applicable. Emitting No as there is only one unit.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Smoke/heat alarm present at ESS location","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.7,"edited":true,"reasoning":"NEC and California fire code require smoke/heat detection where ESS is installed. Standard compliant installation assumes this is present.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Supply side connection per NEC 705.12(A)","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.65,"edited":true,"reasoning":"Tesla Powerwall 3 with Backup Switch typically interconnects on the load side of the main breaker (NEC 705.12(B)), not supply side. No indication of supply-side connection.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"THWN-2 conductors in PV inverter AC output circuit raceway (excl. EGC)","source":"user","raw_value":"2","ai_value":"2","user_value":"2","confidence":0.6,"edited":true,"reasoning":"Standard single-phase 240V AC output from inverter uses 2 THWN-2 conductors (two hots) plus EGC, so 2 excluding EGC.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Total roof area (sq ft)","source":"user","raw_value":"1500","ai_value":"1500","user_value":"1500","confidence":0.4,"edited":true,"reasoning":"No explicit roof area stated. System size of 3.69 kW with 9 modules at 410W suggests modest roof. Typical single-story Apple Valley home estimated at ~1500 sq ft roof area.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Using Power Control System to curtail Inverter 1","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.7,"edited":true,"reasoning":"No mention of power control system or export limiting in any documents. Standard residential installation without curtailment.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Utility available fault current greater than 10 kA at service","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.65,"edited":true,"reasoning":"SCE (Southern California Edison) utility service in residential areas typically provides available fault current greater than 10 kA at the service entrance.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"},{"payload_key":"Utility service feed rating (Amps)","source":"user","raw_value":"200","ai_value":"200","user_value":"200","confidence":0.7,"edited":true,"reasoning":"Standard residential service in California for a home of this size is 200A. No explicit rating stated but MPU listed as TBC in Asana, suggesting existing 200A service.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-29T16:17:33.476528+00:00"}],"artifacts":[{"id":30,"kind":"asana_json","local_path":"/data/runs/01KQD0C34CGNYX4NFQ5TXK5PKZ/asana.json","drive_file_id":null,"sha256":null,"bytes":60283,"downloaded_at":"2026-04-29T16:15:23.396388+00:00"},{"id":31,"kind":"pdf","local_path":"/data/runs/01KQD0C34CGNYX4NFQ5TXK5PKZ/pdf/Aurora_Shade_Report_-_Stacey_Santoro_-_LGCY_Design_-_JobEngine_PV1_-_2026-04-24_111719.pdf","drive_file_id":"1Wy3_5cLAtu15yWB60Qr8y0SwtgtOdTNa","sha256":"a91d13c1918831a2289321a0a9cc8a4591a150a47165572d5a436c0153d0f0d4","bytes":3864987,"downloaded_at":"2026-04-29T16:15:26.893918+00:00"},{"id":32,"kind":"bom","local_path":"/data/runs/01KQD0C34CGNYX4NFQ5TXK5PKZ/bom/BOM_LIS56648.csv","drive_file_id":"1uB8ylVYZ4lLYVEQxWCMgbsgqOH0Chx9X","sha256":"f80b49faad194bac90c7945b81b3eb73b839e52682156ccf431b060f612a69cd","bytes":1734,"downloaded_at":"2026-04-29T16:15:27.494664+00:00"},{"id":33,"kind":"extraction","local_path":"/data/runs/01KQD0C34CGNYX4NFQ5TXK5PKZ/extraction.json","drive_file_id":null,"sha256":null,"bytes":23523,"downloaded_at":"2026-04-29T16:17:02.939033+00:00"}],"has_final_patch":false,"final_patch_field_count":0,"_meta":{"collected_at":"2026-05-06T22:24:16.512103+00:00","iteration_count":0,"audit_log_count":18,"field_values_count":60,"artifacts_count":4,"has_final_patch":false}}