{"run":{"id":"01KQAK70EW95YKS6TQPWQ5TNAE","asana_task_gid":"1214181955813678","asana_task_url":"https://app.asana.com/1/1203754389657527/project/1207873459369363/task/1214181955813678","asana_task_title":"Stacey Santoro","customer_name":"Stacey Santoro","status":"running","current_stage":"submitting","drive_folder_id":"1jk4uZa9rWFojCP18V3vC94vhoVoOOfX4","drive_cad_folder_id":"1ozsPLPvKraYi4klp0BlZmAko4enpLDRU","plan_set_filename":"Aurora Shade Report - Stacey Santoro - LGCY Design - JobEngine PV1 - 2026-04-24 111719.pdf","bom_filename":"BOM_LIS56648.csv","solarapp_uuid":null,"project_url":null,"error_stage":null,"error_message":null,"error_payload":null,"ai_token_usage":{"input_tokens":16687,"output_tokens":6019,"cache_read_input_tokens":5191,"cache_creation_input_tokens":0},"avg_confidence":0.749,"warnings":["Plan set provided is shade report only; no electrical one-line, structural, or roof material details extracted. Roof pitch inferred from 17° angle on shade report. Inverter assumed to be Powerwall 3 integrated (Asana mentions 'Tesla inverter or similar' and BOM lists only Powerwall 3, no separate inverter SKU). Roof covering material is a guess — verify with site survey photos.","Plan set PDF contained only a shade report (3 pages) — no electrical single-line diagram, roof layout, or structural details were present. Many values had to be inferred from equipment specs (Tesla Powerwall 3, SnapNrack UR-45, Q-Cells 410W) and California residential construction norms.","Battery manufacturer listed as Tesla in both Asana and BOM (Powerwall 3 + MCI-2 + Backup Switch). ESS fields filled based on Tesla Powerwall 3 published specifications.","Asana MPU field is 'TBC' — busbar/service rating of 200A is a standard residential inference and must be verified against actual panel.","Total roof area is a rough estimate only (confidence 0.4) — no floor plan or roof layout provided.","ESS installation location defaulted to 'Garage (interior)' as most common Powerwall 3 install location; must be verified from site survey photos.","Rapid Shutdown via Tesla MCI-2 (Module-level Communication Interface) — 3 units for 9 modules (3 modules per MCI-2)."],"flow":"v1","iteration_count":0,"iteration_outcome":null,"final_diagnosis":null,"created_at":"2026-04-28T17:46:55.843414+00:00","updated_at":"2026-04-28T17:51:24.311231+00:00","submitted_at":"2026-04-28T17:51:24.125172+00:00","completed_at":null},"iterations":[],"insights":{"stuck_rules":[],"newly_revealed":[],"conditional_triggers":{}},"audit_log":[{"id":57,"ts":"2026-04-28T17:46:55.857714+00:00","stage":"asana_fetched","level":"info","message":"Resolving Asana task reference 'https://app.asana.com/1/1203754389657527/project/1208103004469323/task/1214181955813678'","payload":null},{"id":58,"ts":"2026-04-28T17:46:56.364321+00:00","stage":"asana_fetched","level":"info","message":"Loaded Asana task: Stacey Santoro","payload":{"gid":"1214181955813678","title":"Stacey Santoro","customer":"Stacey Santoro"}},{"id":59,"ts":"2026-04-28T17:46:56.371659+00:00","stage":"drive_resolved","level":"info","message":"Searching Asana fields for Google Drive URL","payload":null},{"id":60,"ts":"2026-04-28T17:46:57.891266+00:00","stage":"drive_resolved","level":"info","message":"Resolved Drive folder (5 items, 4 in CAD/)","payload":{"folder_id":"1jk4uZa9rWFojCP18V3vC94vhoVoOOfX4","cad_folder_id":"1ozsPLPvKraYi4klp0BlZmAko4enpLDRU"}},{"id":61,"ts":"2026-04-28T17:46:57.898096+00:00","stage":"pdf_downloaded","level":"info","message":"Picking the latest-dated plan-set PDF","payload":null},{"id":62,"ts":"2026-04-28T17:47:00.443599+00:00","stage":"pdf_downloaded","level":"info","message":"Downloaded plan-set: Aurora Shade Report - Stacey Santoro - LGCY Design - JobEngine PV1 - 2026-04-24 111719.pdf (3.7 MB)","payload":{"bytes":3864987,"filename":"Aurora Shade Report - Stacey Santoro - LGCY Design - JobEngine PV1 - 2026-04-24 111719.pdf"}},{"id":63,"ts":"2026-04-28T17:47:00.450218+00:00","stage":"bom_downloaded","level":"info","message":"Looking for the BOM CSV in the same folder","payload":null},{"id":64,"ts":"2026-04-28T17:47:01.064864+00:00","stage":"bom_downloaded","level":"info","message":"Downloaded BOM: BOM_LIS56648.csv (16 rows)","payload":{"rows":16,"filename":"BOM_LIS56648.csv"}},{"id":65,"ts":"2026-04-28T17:47:01.071769+00:00","stage":"ai_extracted","level":"info","message":"Extracting text from the plan-set PDF","payload":null},{"id":66,"ts":"2026-04-28T17:47:01.160387+00:00","stage":"ai_extracted","level":"info","message":"Pass 1/3: Claude Opus 4.7 (full extraction)","payload":null},{"id":67,"ts":"2026-04-28T17:47:20.226896+00:00","stage":"ai_extracted","level":"info","message":"Pass 1: Opus filled 18 fields (avg 86%)","payload":null},{"id":68,"ts":"2026-04-28T17:47:20.241199+00:00","stage":"ai_extracted","level":"info","message":"Pass 2/3: Claude Sonnet 4.6 retrying 41 missing fields","payload":null},{"id":69,"ts":"2026-04-28T17:48:22.438842+00:00","stage":"ai_extracted","level":"info","message":"Pass 2: Sonnet added 41 more fields","payload":null},{"id":70,"ts":"2026-04-28T17:48:22.604998+00:00","stage":"ai_extracted","level":"info","message":"Extracted 59 fields, avg confidence 74% (Opus: 18, Sonnet retry: +41)","payload":{"usage":{"input_tokens":16687,"output_tokens":6019,"cache_read_input_tokens":5191,"cache_creation_input_tokens":0},"fields":59,"passes":{"opus_full":18,"opus_retry":0,"sonnet_retry":41},"missing":0,"extra_fields":0,"avg_confidence":0.749}},{"id":71,"ts":"2026-04-28T17:48:22.621804+00:00","stage":"awaiting_review","level":"info","message":"Pipeline complete — review the extracted fields and submit when ready","payload":null},{"id":72,"ts":"2026-04-28T17:51:24.278255+00:00","stage":"submitting","level":"info","message":"Building SolarAPP+ payload from reviewed fields","payload":null},{"id":73,"ts":"2026-04-28T17:51:24.304598+00:00","stage":"submitting","level":"info","message":"Calling SolarAPP+ create_project + PATCH /details","payload":null}],"field_values":[{"payload_key":"Attachment points staggered","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.65,"edited":true,"reasoning":"SnapNrack UR-45 racking system standard installation practice uses staggered attachment points for structural load distribution.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Busbar #1 already present on site","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.55,"edited":true,"reasoning":"BOM includes a new 60A 2-pole breaker and disconnect switch, suggesting new panel interconnection components rather than an existing busbar already on site.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Busbar #1 rating (Amps)","source":"user","raw_value":"200","ai_value":"200","user_value":"200","confidence":0.55,"edited":true,"reasoning":"Standard residential service in California is typically 200A. The Asana notes MPU as TBC but utility service rating defaults to 200A for residential in this region.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Busbar #1 subject to backfeed","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.85,"edited":true,"reasoning":"Solar PV system with battery storage interconnecting at the main service panel will subject the busbar to backfeed from the inverter/battery system.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Current roof covering material","source":"user","raw_value":"Asphalt or composition shingles","ai_value":"Asphalt or composition shingles","user_value":"Asphalt or composition shingles","confidence":0.6,"edited":true,"reasoning":"Most common residential roof; not specified in plan set text.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Each ESS unit has dedicated OCPD","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.85,"edited":true,"reasoning":"A dedicated 60A 2-pole OCPD is included in the BOM for the ESS unit.","source_excerpt":"24232 60 Amp 2-Pole | af3fdaf5-421c-4977-8033-a47f0da82725 | Whole Home Backup","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"ESS assembly weight (lbs)","source":"user","raw_value":"287","ai_value":"287","user_value":"287","confidence":0.75,"edited":true,"reasoning":"Tesla Powerwall 3 published spec weight is approximately 287 lbs for the wall-mounted unit.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"ESS center of mass less than 4 feet from floor","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.75,"edited":true,"reasoning":"Tesla Powerwall 3 is typically wall-mounted with center of mass well within 4 feet from floor per standard installation.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"ESS in sleeping rooms or closets opening to sleeping rooms","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Tesla Powerwall 3 with Whole Home Backup configuration is typically installed in garage or exterior wall, not in sleeping rooms.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"ESS installation location","source":"user","raw_value":"Garage (interior)","ai_value":"Garage (interior)","user_value":"Garage (interior)","confidence":0.6,"edited":true,"reasoning":"Tesla Powerwall 3 with Whole Home Backup is most commonly installed in an interior garage for residential installations. No explicit location stated in documents.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"ESS location subject to vehicle damage","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.55,"edited":true,"reasoning":"If installed in garage interior (most common location for Powerwall 3), it may be subject to vehicle damage unless protected.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"ESS Model 1 includes DC-coupled expansion unit","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.9,"edited":true,"reasoning":"Tesla Powerwall 3 is an AC-coupled all-in-one unit. Quantity is 1, no DC-coupled expansion listed in BOM.","source_excerpt":"Tesla Powerwall 3 | af3fdaf5-421c-4977-8033-a47f0da82725 | Whole Home Backup","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"ESS Model 1 Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"ESS Model 1 Number","source":"user","raw_value":"Powerwall 3","ai_value":"Powerwall 3","user_value":"Powerwall 3","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"ESS Model 1 Quantity","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"1 | LIS56648 | Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"ESS positively attached to building per manufacturer","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.9,"edited":true,"reasoning":"Tesla Powerwall 3 installation requirements mandate wall-mounting with manufacturer-specified hardware. Standard compliance assumed.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"ESS + PV Inverter certified as single unit (no field wiring)","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.8,"edited":true,"reasoning":"Powerwall 3 is integrated ESS + PV inverter unit.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Flush mount or tilt-up","source":"user","raw_value":"Flush mount","ai_value":"Flush mount","user_value":"Flush mount","confidence":0.85,"edited":true,"reasoning":"SnapNrack UR-45 rail system used for flush rooftop mounting.","source_excerpt":"SnapNrack Domestic UR-45 172\" Rail","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Home has sprinkler systems","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.5,"edited":true,"reasoning":"Single-family residential home in Apple Valley, CA. No sprinkler system mentioned in plan set or Asana. Most existing SFR homes in this area do not have sprinklers unless newer construction requiring it.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Homeowner Full Name","source":"user","raw_value":"Stacey Santoro","ai_value":"Stacey Santoro","user_value":"Stacey Santoro","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"Customer Name: Stacey Santoro","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Inverter 1 interconnection location","source":"user","raw_value":"Main Service Panel","ai_value":"Main Service Panel","user_value":"Main Service Panel","confidence":0.7,"edited":true,"reasoning":"Tesla Powerwall 3 with Backup Switch (whole home backup) interconnects at the main service panel. BOM includes Tesla Backup Switch indicating MSP-level interconnection.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Inverter 1 Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Inverter 1 Model Number","source":"user","raw_value":"Powerwall 3","ai_value":"Powerwall 3","user_value":"Powerwall 3","confidence":0.85,"edited":true,"reasoning":"Powerwall 3 contains the integrated PV inverter; no separate Tesla inverter SKU on BOM.","source_excerpt":"Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Inverter 1 OCPD rating (Amps)","source":"user","raw_value":"60","ai_value":"60","user_value":"60","confidence":0.82,"edited":true,"reasoning":"The BOM lists a 60A 2-pole breaker consistent with Tesla Powerwall 3 / integrated inverter OCPD.","source_excerpt":"24232 60 Amp 2-Pole | af3fdaf5-421c-4977-8033-a47f0da82725 | Whole Home Backup","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Inverter 1 power setting (kW)","source":"user","raw_value":"3.69","ai_value":"3.69","user_value":"3.69","confidence":0.85,"edited":true,"reasoning":"System size is listed as 3.69 kWDC in Asana custom fields.","source_excerpt":"KW\": \"3.69\"","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Inverter architecture type","source":"user","raw_value":"String Inverter without DC-DC Converters","ai_value":"String Inverter without DC-DC Converters","user_value":"String Inverter without DC-DC Converters","confidence":0.6,"edited":true,"reasoning":"Powerwall 3 has integrated string PV inverter with MPPTs; no DC optimizers in BOM.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Max DC PV Wire / USE-2 conductors in raceway (excl. EGC)","source":"user","raw_value":"2","ai_value":"2","user_value":"2","confidence":0.6,"edited":true,"reasoning":"Single string of 9 modules with Tesla Powerwall 3 integrated inverter. Typical DC wiring uses 2 conductors (positive and negative) in raceway.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Max DC THWN-2 conductors in raceway (excl. EGC)","source":"user","raw_value":"2","ai_value":"2","user_value":"2","confidence":0.55,"edited":true,"reasoning":"For a single-string DC circuit, 2 THWN-2 conductors (positive and negative) in conduit is standard.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Maximum distance from module to roof (inches)","source":"user","raw_value":"10","ai_value":"10","user_value":"10","confidence":0.65,"edited":true,"reasoning":"SnapNrack UR-45 low-profile racking system. Standard module standoff height with UltraFoot mounts is approximately 6-10 inches. Using 10 inches as the typical maximum for this racking system.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Maximum input DC open circuit voltage (Voc) of PV inverter","source":"user","raw_value":"600","ai_value":"600","user_value":"600","confidence":0.75,"edited":true,"reasoning":"Tesla Powerwall 3 integrated inverter has a maximum DC input Voc of 600V per published specifications.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Maximum input DC short circuit current (Isc) of PV inverter","source":"user","raw_value":"20","ai_value":"20","user_value":"20","confidence":0.65,"edited":true,"reasoning":"Tesla Powerwall 3 integrated inverter maximum DC input Isc is approximately 20A per published specifications.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Maximum number of modules in a DC series string","source":"user","raw_value":"9","ai_value":"9","user_value":"9","confidence":0.9,"edited":true,"reasoning":"Total of 9 modules in the system. Shade report shows 1 array of 9 panels. With Powerwall 3 integrated inverter, all 9 are in a single string.","source_excerpt":"10893 | 9 | LIS56648 | QCELLS Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Maximum OCPD rating allowed on Inverter 1 (Amps)","source":"user","raw_value":"60","ai_value":"60","user_value":"60","confidence":0.8,"edited":true,"reasoning":"Tesla Powerwall 3 maximum OCPD per manufacturer specification is 60A; confirmed by 60A 2-pole breaker in BOM.","source_excerpt":"24232 60 Amp 2-Pole | af3fdaf5-421c-4977-8033-a47f0da82725 | Whole Home Backup","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Maximum spacing between adjacent attachment points (inches)","source":"user","raw_value":"72","ai_value":"72","user_value":"72","confidence":0.65,"edited":true,"reasoning":"SnapNrack UR-45 racking system standard maximum rafter spacing / attachment point spacing is typically 72 inches (6 feet) for residential composite shingle roofs.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Module 1 Quantity","source":"user","raw_value":"9","ai_value":"9","user_value":"9","confidence":0.98,"edited":true,"reasoning":null,"source_excerpt":"9 | LIS56648 | QCELLS Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Module fire rating type","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.85,"edited":true,"reasoning":"Hanwha Q-Cells Q.PEAK DUO BLK ML-G10.C+ 410 modules are Class A (fire rating type 1) certified, standard for residential PV on composite shingle roofs.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Module is bifacial","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.85,"edited":true,"reasoning":"Q.PEAK DUO BLK ML-G10.C+ is monofacial all-black module.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Module Manufacturer","source":"user","raw_value":"Hanwha Q CELLS","ai_value":"Hanwha Q CELLS","user_value":"Hanwha Q CELLS","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"QCELLS Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Module Model Number","source":"user","raw_value":"Q.PEAK DUO BLK ML-G10.C+ 410","ai_value":"Q.PEAK DUO BLK ML-G10.C+ 410","user_value":"Q.PEAK DUO BLK ML-G10.C+ 410","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"QCELLS Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Number of busbars","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.7,"edited":true,"reasoning":"Single residential service panel system with one main busbar for interconnection. No subpanel mentioned.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Number of composite shingle layers","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.65,"edited":true,"reasoning":"Standard residential construction. No re-roofing or double-layer mentioned in Asana or plan set. Default assumption is 1 layer of composite shingles.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Number of distinct ESS models","source":"user","raw_value":"1","ai_value":"1","user_value":"1","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"OCPD protecting busbar #1 rating (Amps)","source":"user","raw_value":"200","ai_value":"200","user_value":"200","confidence":0.55,"edited":true,"reasoning":"Standard residential main breaker rating is 200A. The main OCPD protecting the busbar would be the main breaker at 200A.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"PV system weight (lbs/sq ft)","source":"user","raw_value":"3.0","ai_value":"3.0","user_value":"3.0","confidence":0.65,"edited":true,"reasoning":"SnapNrack UR-45 with Q-Cells 410W modules. Typical installed PV system weight (modules + racking) is approximately 2.5-3.5 lbs/sq ft. Using 3.0 as standard estimate.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Racking System Manufacturer","source":"user","raw_value":"SnapNrack","ai_value":"SnapNrack","user_value":"SnapNrack","confidence":0.95,"edited":true,"reasoning":null,"source_excerpt":"SnapNrack Domestic UR-45 172\" Rail - Mill, 232-10095-USA","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Racking System Model Number","source":"user","raw_value":"Ultra Rail (UR-45)","ai_value":"Ultra Rail (UR-45)","user_value":"Ultra Rail (UR-45)","confidence":0.85,"edited":true,"reasoning":null,"source_excerpt":"SnapNrack Domestic UR-45 172\" Rail","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Rapid Shutdown compliance method inside array","source":"user","raw_value":"Module-Level Power Electronics (MLPE)","ai_value":"Module-Level Power Electronics (MLPE)","user_value":"Module-Level Power Electronics (MLPE)","confidence":0.75,"edited":true,"reasoning":"Tesla MCI-2 is a module-level communication interface that enables rapid shutdown via MLPE compliance method per NEC 690.12.","source_excerpt":"Tesla MCI-2 | af3fdaf5-421c-4977-8033-a47f0da82725 | Whole Home Backup","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Rapid Shutdown Device Manufacturer","source":"user","raw_value":"Tesla","ai_value":"Tesla","user_value":"Tesla","confidence":0.75,"edited":true,"reasoning":"Tesla MCI-2 (Module-level Communication Interface) provides rapid shutdown compliance as part of the Tesla Powerwall 3 ecosystem.","source_excerpt":"Tesla MCI-2 | af3fdaf5-421c-4977-8033-a47f0da82725 | Whole Home Backup","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Rapid Shutdown Device Model Number","source":"user","raw_value":"MCI-2","ai_value":"MCI-2","user_value":"MCI-2","confidence":0.75,"edited":true,"reasoning":"Tesla MCI-2 listed in BOM with quantity 3, used for rapid shutdown compliance at module level.","source_excerpt":"Tesla MCI-2 | af3fdaf5-421c-4977-8033-a47f0da82725 | Whole Home Backup","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Roof penetration sealant method name and description","source":"user","raw_value":"SnapNrack UltraFoot with EPDM gasket and butyl sealant; lag bolt through flashed mount into rafter","ai_value":"SnapNrack UltraFoot with EPDM gasket and butyl sealant; lag bolt through flashed mount into rafter","user_value":"SnapNrack UltraFoot with EPDM gasket and butyl sealant; lag bolt through flashed mount into rafter","confidence":0.65,"edited":true,"reasoning":"SnapNrack UltraFoot mounts use integrated EPDM gasket sealing with additional butyl tape/sealant per manufacturer installation guidelines.","source_excerpt":"SNr UltraFoot Rafter Black - Domestic | ... | Lag Bolts","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Roof pitch","source":"user","raw_value":"4/12","ai_value":"4/12","user_value":"4/12","confidence":0.55,"edited":true,"reasoning":"Shade report shows 17° pitch which is roughly 4/12 (3.7/12).","source_excerpt":"9 135° 17° 94% 98% 92%","in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Separation between ESS units less than 3 feet","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.8,"edited":true,"reasoning":"Only 1 Tesla Powerwall 3 unit in the BOM. With a single ESS unit, separation between units is not applicable / No.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Smoke/heat alarm present at ESS location","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.7,"edited":true,"reasoning":"California building code and NEC 2020 requirements for ESS installations mandate smoke/heat detection. Residential garage installations in CA are required to have detection.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Supply side connection per NEC 705.12(A)","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.65,"edited":true,"reasoning":"Tesla Powerwall 3 with Backup Switch typically interconnects load-side at the main panel per NEC 705.12(B), not supply-side. No indication of supply-side connection in documents.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"THWN-2 conductors in PV inverter AC output circuit raceway (excl. EGC)","source":"user","raw_value":"2","ai_value":"2","user_value":"2","confidence":0.6,"edited":true,"reasoning":"Standard AC output circuit from Tesla Powerwall 3 inverter uses 2 THWN-2 conductors (line and neutral) plus EGC in conduit.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Total roof area (sq ft)","source":"user","raw_value":"1800","ai_value":"1800","user_value":"1800","confidence":0.4,"edited":true,"reasoning":"No roof area explicitly stated. Shade report shows 9 modules at 17-degree pitch on 135-degree azimuth. Estimating based on typical single-family home in Apple Valley, CA area.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Using Power Control System to curtail Inverter 1","source":"user","raw_value":"No","ai_value":"No","user_value":"No","confidence":0.7,"edited":true,"reasoning":"No power control system or curtailment device mentioned in Asana, BOM, or plan set. Standard residential installation without export limitation.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Utility available fault current greater than 10 kA at service","source":"user","raw_value":"Yes","ai_value":"Yes","user_value":"Yes","confidence":0.65,"edited":true,"reasoning":"SCE (Southern California Edison) utility service in residential areas typically provides available fault current exceeding 10 kA at the service entrance.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"},{"payload_key":"Utility service feed rating (Amps)","source":"user","raw_value":"200","ai_value":"200","user_value":"200","confidence":0.65,"edited":true,"reasoning":"Standard residential utility service rating in California is 200A. MPU listed as TBC in Asana but 200A is the standard default for single-family residential.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:51:24.125172+00:00"}],"artifacts":[{"id":17,"kind":"asana_json","local_path":"/data/runs/01KQAK70EW95YKS6TQPWQ5TNAE/asana.json","drive_file_id":null,"sha256":null,"bytes":54628,"downloaded_at":"2026-04-28T17:46:56.349954+00:00"},{"id":18,"kind":"pdf","local_path":"/data/runs/01KQAK70EW95YKS6TQPWQ5TNAE/pdf/Aurora_Shade_Report_-_Stacey_Santoro_-_LGCY_Design_-_JobEngine_PV1_-_2026-04-24_111719.pdf","drive_file_id":"1Wy3_5cLAtu15yWB60Qr8y0SwtgtOdTNa","sha256":"a91d13c1918831a2289321a0a9cc8a4591a150a47165572d5a436c0153d0f0d4","bytes":3864987,"downloaded_at":"2026-04-28T17:47:00.428030+00:00"},{"id":19,"kind":"bom","local_path":"/data/runs/01KQAK70EW95YKS6TQPWQ5TNAE/bom/BOM_LIS56648.csv","drive_file_id":"1uB8ylVYZ4lLYVEQxWCMgbsgqOH0Chx9X","sha256":"f80b49faad194bac90c7945b81b3eb73b839e52682156ccf431b060f612a69cd","bytes":1734,"downloaded_at":"2026-04-28T17:47:01.049350+00:00"},{"id":20,"kind":"extraction","local_path":"/data/runs/01KQAK70EW95YKS6TQPWQ5TNAE/extraction.json","drive_file_id":null,"sha256":null,"bytes":23687,"downloaded_at":"2026-04-28T17:48:22.455446+00:00"}],"has_final_patch":false,"final_patch_field_count":0,"_meta":{"collected_at":"2026-05-06T22:25:44.769633+00:00","iteration_count":0,"audit_log_count":17,"field_values_count":59,"artifacts_count":4,"has_final_patch":false}}