{"run":{"id":"01KQAJZE0AWC7D2R78QSJ8H7CT","asana_task_gid":"1214016163628485","asana_task_url":"https://app.asana.com/1/1203754389657527/project/1207873459369363/task/1214016163628485","asana_task_title":"Daniel Martinez Noriega","customer_name":"Daniel Martinez Noriega","status":"awaiting_review","current_stage":"awaiting_review","drive_folder_id":"1An0edHhDk5tFVtXUV4hK9COsZrXz6ys4","drive_cad_folder_id":"1c5s9FE-i_5SxibhGGDKpc0xd8vnRVHHL","plan_set_filename":"Daniel Martinez Noriega_LGCY_V5_04-23-2026.pdf","bom_filename":"BOM_LIS56437.csv","solarapp_uuid":null,"project_url":null,"error_stage":null,"error_message":null,"error_payload":null,"ai_token_usage":{"input_tokens":61909,"output_tokens":6143,"cache_read_input_tokens":0,"cache_creation_input_tokens":5191},"avg_confidence":0.85,"warnings":["Roof pitch listed as 7° tilt; converted to ~1.5/12, rounded to 1/12 - reviewer should verify.","ESS install location inferred as outdoor wall based on site plan showing equipment on south outside wall.","Number of composite shingle layers not stated; defaulted to 1.","Inverter architecture: Powerwall 3 with MCI-2 rapid shutdown devices treated as string inverter without DC-DC converters.","Attachment points staggered: No explicit stagger notation in plan set. SnapNrack UltraFoot Deck at 24\" O.C. on 24\" O.C. truss framing — typically aligned (not staggered) in this configuration. Reviewer should verify against attachment detail.","Max DC THWN-2 conductors: Raceway 2 table shows '4/3' conductor count notation; interpreted as 3 THWN-2 current-carrying conductors + 1 EGC (16 AWG THWN-2 listed separately). Reviewer should confirm table reading.","PV system weight (lbs/sq ft): Not explicitly stated anywhere in the plan set or BOM. Value of 3.5 lbs/sq ft is an engineering estimate based on 15x Qcells modules (~44 lbs each) over 317 sq ft array area plus racking weight. Reviewer must verify against structural calculations if available.","Module fire rating type: Stated as Type 1 (Class A) per standard classification for listed PV modules on Class A comp shingle roofs per CFC/IBC. Plan notes modules are 'non-combustible.'","Utility available fault current: No explicit fault current value provided by utility or in plan set. Rural underground SCE service in Piñon Hills typically below 10 kA; reviewer should confirm with utility documentation."],"flow":"v1","iteration_count":0,"iteration_outcome":null,"final_diagnosis":null,"created_at":"2026-04-28T17:42:47.566020+00:00","updated_at":"2026-04-28T17:44:22.742681+00:00","submitted_at":null,"completed_at":null},"iterations":[],"insights":{"stuck_rules":[],"newly_revealed":[],"conditional_triggers":{}},"audit_log":[{"id":42,"ts":"2026-04-28T17:42:47.577816+00:00","stage":"asana_fetched","level":"info","message":"Resolving Asana task reference 'https://app.asana.com/1/1203754389657527/project/1208103004469323/task/1214016163628485'","payload":null},{"id":43,"ts":"2026-04-28T17:42:48.131740+00:00","stage":"asana_fetched","level":"info","message":"Loaded Asana task: Daniel Martinez Noriega","payload":{"gid":"1214016163628485","title":"Daniel Martinez Noriega","customer":"Daniel Martinez Noriega"}},{"id":44,"ts":"2026-04-28T17:42:48.138100+00:00","stage":"drive_resolved","level":"info","message":"Searching Asana fields for Google Drive URL","payload":null},{"id":45,"ts":"2026-04-28T17:42:49.438148+00:00","stage":"drive_resolved","level":"info","message":"Resolved Drive folder (5 items, 4 in CAD/)","payload":{"folder_id":"1An0edHhDk5tFVtXUV4hK9COsZrXz6ys4","cad_folder_id":"1c5s9FE-i_5SxibhGGDKpc0xd8vnRVHHL"}},{"id":46,"ts":"2026-04-28T17:42:49.447428+00:00","stage":"pdf_downloaded","level":"info","message":"Picking the latest-dated plan-set PDF","payload":null},{"id":47,"ts":"2026-04-28T17:42:51.780908+00:00","stage":"pdf_downloaded","level":"info","message":"Downloaded plan-set: Daniel Martinez Noriega_LGCY_V5_04-23-2026.pdf (6.2 MB)","payload":{"bytes":6514576,"filename":"Daniel Martinez Noriega_LGCY_V5_04-23-2026.pdf"}},{"id":48,"ts":"2026-04-28T17:42:51.787412+00:00","stage":"bom_downloaded","level":"info","message":"Looking for the BOM CSV in the same folder","payload":null},{"id":49,"ts":"2026-04-28T17:42:52.501734+00:00","stage":"bom_downloaded","level":"info","message":"Downloaded BOM: BOM_LIS56437.csv (20 rows)","payload":{"rows":20,"filename":"BOM_LIS56437.csv"}},{"id":50,"ts":"2026-04-28T17:42:52.508700+00:00","stage":"ai_extracted","level":"info","message":"Extracting text from the plan-set PDF","payload":null},{"id":51,"ts":"2026-04-28T17:42:54.988715+00:00","stage":"ai_extracted","level":"info","message":"Pass 1/3: Claude Opus 4.7 (full extraction)","payload":null},{"id":52,"ts":"2026-04-28T17:43:51.565707+00:00","stage":"ai_extracted","level":"info","message":"Pass 1: Opus filled 51 fields (avg 86%)","payload":null},{"id":53,"ts":"2026-04-28T17:43:51.582997+00:00","stage":"ai_extracted","level":"info","message":"Pass 2/3: Claude Sonnet 4.6 retrying 8 missing fields","payload":null},{"id":54,"ts":"2026-04-28T17:44:22.553274+00:00","stage":"ai_extracted","level":"info","message":"Pass 2: Sonnet added 8 more fields","payload":null},{"id":55,"ts":"2026-04-28T17:44:22.733834+00:00","stage":"ai_extracted","level":"info","message":"Extracted 59 fields, avg confidence 85% (Opus: 51, Sonnet retry: +8)","payload":{"usage":{"input_tokens":61909,"output_tokens":6143,"cache_read_input_tokens":0,"cache_creation_input_tokens":5191},"fields":59,"passes":{"opus_full":51,"opus_retry":0,"sonnet_retry":8},"missing":0,"extra_fields":0,"avg_confidence":0.85}},{"id":56,"ts":"2026-04-28T17:44:22.749068+00:00","stage":"awaiting_review","level":"info","message":"Pipeline complete — review the extracted fields and submit when ready","payload":null}],"field_values":[{"payload_key":"Attachment points staggered","source":"inferred","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.55,"edited":false,"reasoning":"The plan set shows SnapNrack UltraFoot Deck attachments at 24\" O.C. on a truss roof (2x2 truss 24\" O.C.). With single-rail portrait mounting on a truss roof at 24\" O.C. spacing, attachments are typically aligned (not staggered) along a single rail line. No explicit stagger notation appears in the plan set.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Busbar #1 already present on site","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Busbar #1 rating (Amps)","source":"pdf","raw_value":"200","ai_value":"200","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Busbar #1 subject to backfeed","source":"inferred","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.7,"edited":false,"reasoning":"PV/ESS feeds back through subpanel to MSP.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Current roof covering material","source":"pdf","raw_value":"Asphalt or composition shingles","ai_value":"Asphalt or composition shingles","user_value":null,"confidence":0.97,"edited":false,"reasoning":null,"source_excerpt":"ROOF MATERIAL: COMP SHINGLE","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Each ESS unit has dedicated OCPD","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.7,"edited":false,"reasoning":null,"source_excerpt":"60A breaker","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"ESS assembly weight (lbs)","source":"pdf","raw_value":"291","ai_value":"291","user_value":null,"confidence":0.9,"edited":false,"reasoning":null,"source_excerpt":"Total Weight of Installed Unit 132 kg (291.2 lb)","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"ESS center of mass less than 4 feet from floor","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.7,"edited":false,"reasoning":"Powerwall 3 is ~43.5 in tall; floor mount or low wall mount keeps CoM under 4 ft.","source_excerpt":"Dimensions 1105 x 609 x 193 mm (43.5 x 24 x 7.6 in)","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"ESS in sleeping rooms or closets opening to sleeping rooms","source":"pdf","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.85,"edited":false,"reasoning":null,"source_excerpt":"ESS EQUIPMENT SHALL BE LOCATED 3' FROM ALL DOORS AND WINDOWS DIRECTLY ENTERING THE DWELLING UNIT","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"ESS installation location","source":"inferred","raw_value":"Outdoor walls","ai_value":"Outdoor walls","user_value":null,"confidence":0.6,"edited":false,"reasoning":"Plan shows ESS on south outside wall; AC disconnect on south outside wall.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"ESS location subject to vehicle damage","source":"inferred","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.7,"edited":false,"reasoning":null,"source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"ESS Model 1 includes DC-coupled expansion unit","source":"bom","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.85,"edited":false,"reasoning":"BOM lists only 1 Powerwall 3, no Expansion units.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"ESS Model 1 Manufacturer","source":"bom","raw_value":"Tesla","ai_value":"Tesla","user_value":null,"confidence":0.99,"edited":false,"reasoning":null,"source_excerpt":"Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"ESS Model 1 Number","source":"bom","raw_value":"Powerwall 3","ai_value":"Powerwall 3","user_value":null,"confidence":0.97,"edited":false,"reasoning":null,"source_excerpt":"Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"ESS Model 1 Quantity","source":"bom","raw_value":"1","ai_value":"1","user_value":null,"confidence":0.99,"edited":false,"reasoning":null,"source_excerpt":"Tesla Powerwall 3 qty 1","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"ESS positively attached to building per manufacturer","source":"inferred","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.8,"edited":false,"reasoning":null,"source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"ESS + PV Inverter certified as single unit (no field wiring)","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.85,"edited":false,"reasoning":null,"source_excerpt":"ENERGY STORAGE SYSTEM INTEGRATED INVERTER","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Flush mount or tilt-up","source":"pdf","raw_value":"Flush mount","ai_value":"Flush mount","user_value":null,"confidence":0.9,"edited":false,"reasoning":null,"source_excerpt":"PHOTOVOLTAIC ROOF MOUNT SYSTEM","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Home has sprinkler systems","source":"pdf","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"Sprinklers: No","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Homeowner Full Name","source":"asana","raw_value":"Daniel Martinez Noriega","ai_value":"Daniel Martinez Noriega","user_value":null,"confidence":0.99,"edited":false,"reasoning":null,"source_excerpt":"Customer Name: Daniel Martinez Noriega","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Inverter 1 interconnection location","source":"pdf","raw_value":"New Subpanel","ai_value":"New Subpanel","user_value":null,"confidence":0.8,"edited":false,"reasoning":null,"source_excerpt":"INTERCONNECTION: BREAKER TIE-IN AT SUBPANEL","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Inverter 1 Manufacturer","source":"bom","raw_value":"Tesla","ai_value":"Tesla","user_value":null,"confidence":0.97,"edited":false,"reasoning":null,"source_excerpt":"Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Inverter 1 Model Number","source":"pdf","raw_value":"Powerwall 3 (1707000-xx-y)","ai_value":"Powerwall 3 (1707000-xx-y)","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"TESLA: POWERWALL 3 (1707000-XX-Y) 11.5KW, 13.5KWH","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Inverter 1 OCPD rating (Amps)","source":"pdf","raw_value":"60","ai_value":"60","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"60A OCPD - OK","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Inverter 1 power setting (kW)","source":"pdf","raw_value":"11.5","ai_value":"11.5","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"11.500 kWAC","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Inverter architecture type","source":"inferred","raw_value":"String Inverter without DC-DC Converters","ai_value":"String Inverter without DC-DC Converters","user_value":null,"confidence":0.7,"edited":false,"reasoning":"Powerwall 3 is a string inverter with MCI rapid shutdown devices (not DC-DC optimizers).","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Max DC PV Wire / USE-2 conductors in raceway (excl. EGC)","source":"pdf","raw_value":"4","ai_value":"4","user_value":null,"confidence":0.92,"edited":false,"reasoning":"Raceway 1 (DC, MCI to Junction Box) explicitly lists 4 conductors of 10 AWG PV Wire (USE-2 equivalent), excluding EGC.","source_excerpt":"RACEWAY 1 DC MCI TO JUNCTION BOX 4- 10 AWG PV WIRE-","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Max DC THWN-2 conductors in raceway (excl. EGC)","source":"pdf","raw_value":"3","ai_value":"3","user_value":null,"confidence":0.92,"edited":false,"reasoning":"Raceway 2 (DC, Junction Box to Tesla Powerwall 3) lists 3 conductors of 10 AWG THWN-2 (the '4/3' notation means 4 total wires, 3 current-carrying THWN-2 excl. EGC, with the EGC being 16 AWG THWN-2).","source_excerpt":"RACEWAY 2 DC JUNCTION BOX TO TESLA POWERWALL 3 4/3 3/4\" EMT CONDUIT RUN 10 AWG THWN-2 COPPER","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Maximum distance from module to roof (inches)","source":"pdf","raw_value":"6","ai_value":"6","user_value":null,"confidence":0.85,"edited":false,"reasoning":null,"source_excerpt":"3\" MIN. 6\" MAX.","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Maximum input DC open circuit voltage (Voc) of PV inverter","source":"pdf","raw_value":"600","ai_value":"600","user_value":null,"confidence":0.9,"edited":false,"reasoning":null,"source_excerpt":"Withstand Voltage 600 V DC","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Maximum input DC short circuit current (Isc) of PV inverter","source":"pdf","raw_value":"19","ai_value":"19","user_value":null,"confidence":0.85,"edited":false,"reasoning":null,"source_excerpt":"Maximum Short Circuit Current per MPPT (Isc) 19 A","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Maximum number of modules in a DC series string","source":"pdf","raw_value":"8","ai_value":"8","user_value":null,"confidence":0.9,"edited":false,"reasoning":null,"source_excerpt":"(N) 8 MODULES IN BRANCH CIRCUIT #1","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Maximum OCPD rating allowed on Inverter 1 (Amps)","source":"pdf","raw_value":"60","ai_value":"60","user_value":null,"confidence":0.9,"edited":false,"reasoning":null,"source_excerpt":"Overcurrent Protection Device 60 A","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Maximum spacing between adjacent attachment points (inches)","source":"pdf","raw_value":"24","ai_value":"24","user_value":null,"confidence":0.93,"edited":false,"reasoning":"Plan set explicitly states attachments at 24\" O.C. MAX.","source_excerpt":"(N) SNAPNRACK ULTRA FOOT DECK BLACK ATTACHMENTS @ 24\" O.C MAX","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Module 1 Quantity","source":"bom","raw_value":"15","ai_value":"15","user_value":null,"confidence":0.99,"edited":false,"reasoning":null,"source_excerpt":"15 ... QCELLS Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Module fire rating type","source":"inferred","raw_value":"1","ai_value":"1","user_value":null,"confidence":0.85,"edited":false,"reasoning":"The roof is composite shingle (Class A fire rating roof). The Hanwha Q-Cells Q.PEAK DUO BLK ML-G10.C+ 410 modules on a Class A composite shingle roof achieve a Type 1 (Class A) fire rating classification. The plan notes 'THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE' and governing codes are 2025 CFC. Class A / fire rating type 1 is standard for this module/roof combination.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Module is bifacial","source":"inferred","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.85,"edited":false,"reasoning":"Q.PEAK DUO BLK ML-G10.C+ is a black-backsheet monofacial module.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Module Manufacturer","source":"bom","raw_value":"Qcells","ai_value":"Qcells","user_value":null,"confidence":0.97,"edited":false,"reasoning":null,"source_excerpt":"QCELLS Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Module Model Number","source":"bom","raw_value":"Q.PEAK DUO BLK ML-G10.C+ 410","ai_value":"Q.PEAK DUO BLK ML-G10.C+ 410","user_value":null,"confidence":0.97,"edited":false,"reasoning":null,"source_excerpt":"QCELLS Q.PEAK DUO BLK ML-G10.C+ 410","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Number of busbars","source":"pdf","raw_value":"2","ai_value":"2","user_value":null,"confidence":0.6,"edited":false,"reasoning":"Existing 200A MSP busbar plus new 125A subpanel busbar.","source_excerpt":"(E) 200A MAIN SERVICE PANEL ... (N) 125A SUB PANEL","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Number of composite shingle layers","source":"inferred","raw_value":"1","ai_value":"1","user_value":null,"confidence":0.5,"edited":false,"reasoning":"Standard assumption for single-layer comp shingle roof; not explicitly stated.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Number of distinct ESS models","source":"bom","raw_value":"1","ai_value":"1","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"Tesla Powerwall 3","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"OCPD protecting busbar #1 rating (Amps)","source":"pdf","raw_value":"200","ai_value":"200","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"(E) 200A MAIN BREAKER","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"PV system weight (lbs/sq ft)","source":"inferred","raw_value":"3.5","ai_value":"3.5","user_value":null,"confidence":0.5,"edited":false,"reasoning":"No explicit lbs/sq ft value is stated in the plan set, PDF, or BOM. The array area is 317.03 sq ft (from plan set). The Qcells Q.PEAK DUO BLK ML-G10.C+ 410 module weighs approximately 44.1 lbs each; 15 modules = 661.5 lbs. Adding racking (~0.5 lb/sq ft), estimated total is ~2.6 lbs/sq ft for modules alone. Typical residential rail-mount systems run 2.5–4 lbs/sq ft. Using ~3.5 lbs/sq ft as a reasonable midpoint estimate for modules + racking on a comp shingle roof.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Racking System Manufacturer","source":"bom","raw_value":"SnapNrack","ai_value":"SnapNrack","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"SnapNrack Domestic UR-45 172\" Rail","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Racking System Model Number","source":"pdf","raw_value":"Ultra Rail UR-45","ai_value":"Ultra Rail UR-45","user_value":null,"confidence":0.9,"edited":false,"reasoning":null,"source_excerpt":"(N) SNAPNRACK UR-45 RAIL","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Rapid Shutdown compliance method inside array","source":"pdf","raw_value":"PV Hazard Control System (UL 3741)","ai_value":"PV Hazard Control System (UL 3741)","user_value":null,"confidence":0.7,"edited":false,"reasoning":null,"source_excerpt":"UL 3741, PVRSE (Photovoltaic Rapid Shutdown Equipment)","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Rapid Shutdown Device Manufacturer","source":"bom","raw_value":"Tesla","ai_value":"Tesla","user_value":null,"confidence":0.97,"edited":false,"reasoning":null,"source_excerpt":"Tesla MCI-2","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Rapid Shutdown Device Model Number","source":"bom","raw_value":"MCI-2","ai_value":"MCI-2","user_value":null,"confidence":0.97,"edited":false,"reasoning":null,"source_excerpt":"Tesla MCI-2","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Roof penetration sealant method name and description","source":"pdf","raw_value":"SnapNrack UltraFoot Deck with SpeedSeal+ pre-applied butyl pad","ai_value":"SnapNrack UltraFoot Deck with SpeedSeal+ pre-applied butyl pad","user_value":null,"confidence":0.85,"edited":false,"reasoning":null,"source_excerpt":"SpeedSeal+ Technology, a pre-installed butyl pad","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Roof pitch","source":"pdf","raw_value":"1/12","ai_value":"1/12","user_value":null,"confidence":0.6,"edited":false,"reasoning":"7 degrees ≈ 1.5/12; rounded to 1/12 (closer is 1.5/12 but integer N/12 expected).","source_excerpt":"ROOF TILT 7°","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Separation between ESS units less than 3 feet","source":"inferred","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.85,"edited":false,"reasoning":"Only 1 ESS unit installed.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Smoke/heat alarm present at ESS location","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.7,"edited":false,"reasoning":null,"source_excerpt":"INTERCONNECTED SMOKE ALARMS ARE REQUIRED TO BE INSTALLED THROUGHOUT YOUR HOUSE","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Supply side connection per NEC 705.12(A)","source":"pdf","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.9,"edited":false,"reasoning":null,"source_excerpt":"INTERCONNECTION: BREAKER TIE-IN AT SUBPANEL","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"THWN-2 conductors in PV inverter AC output circuit raceway (excl. EGC)","source":"pdf","raw_value":"3","ai_value":"3","user_value":null,"confidence":0.92,"edited":false,"reasoning":"Raceway 3 (AC, Tesla Powerwall 3 to AC Disconnect) lists 3 conductors of 6 AWG THWN-2 (excluding EGC which is also 6 AWG THWN-2 listed separately). This is the inverter AC output circuit.","source_excerpt":"RACEWAY 3 AC TESLA POWERWALL 3 TO AC DISCONNECT 3 3/4\" EMT CONDUIT RUN 6 AWG THWN-2 COPPER","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Total roof area (sq ft)","source":"pdf","raw_value":"1739","ai_value":"1739","user_value":null,"confidence":0.85,"edited":false,"reasoning":null,"source_excerpt":"AREA OF ROOF (PLAN VIEW)(Sq. Ft.) 1739.21","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Using Power Control System to curtail Inverter 1","source":"pdf","raw_value":"Yes","ai_value":"Yes","user_value":null,"confidence":0.9,"edited":false,"reasoning":null,"source_excerpt":"PANEL LIMIT FEATURE FOR THE POWERWALL UNIT(S) TO BE UTILIZED... PCS CONTROLLED CURRENT SETTING: 100A","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Utility available fault current greater than 10 kA at service","source":"inferred","raw_value":"No","ai_value":"No","user_value":null,"confidence":0.65,"edited":false,"reasoning":"The Tesla Powerwall 3 datasheet lists Maximum Short-Circuit Current Rating of 10 kA. The Tesla Backup Switch has a Short Circuit Current Rating of 22 kA with breaker. The project is in Piñon Hills, CA (rural San Bernardino County), a rural area where available fault current at the service entrance is typically low (well under 10 kA for underground rural services). No explicit utility fault current value is stated; however, the rural underground service location and the 10 kA equipment ratings suggest fault current at or below 10 kA.","source_excerpt":null,"in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"},{"payload_key":"Utility service feed rating (Amps)","source":"pdf","raw_value":"200","ai_value":"200","user_value":null,"confidence":0.95,"edited":false,"reasoning":null,"source_excerpt":"(E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER","in_field_map":true,"updated_at":"2026-04-28T17:44:22.579292+00:00"}],"artifacts":[{"id":13,"kind":"asana_json","local_path":"/data/runs/01KQAJZE0AWC7D2R78QSJ8H7CT/asana.json","drive_file_id":null,"sha256":null,"bytes":60455,"downloaded_at":"2026-04-28T17:42:48.114660+00:00"},{"id":14,"kind":"pdf","local_path":"/data/runs/01KQAJZE0AWC7D2R78QSJ8H7CT/pdf/Daniel_Martinez_Noriega_LGCY_V5_04-23-2026.pdf","drive_file_id":"1BkqR8GvfC1e7dXHPZE7LE_NIMIPbzWDA","sha256":"45f5dfe4628b3a5ac83d8d74b57248432f8bc0286985b6f7f28e3c4358820a60","bytes":6514576,"downloaded_at":"2026-04-28T17:42:51.766547+00:00"},{"id":15,"kind":"bom","local_path":"/data/runs/01KQAJZE0AWC7D2R78QSJ8H7CT/bom/BOM_LIS56437.csv","drive_file_id":"1vENN8VK7BFuo4waOJcU6CHh4nQS1YaId","sha256":"88a4931866e8ec52e8fa6e37350af0d6fe132e277d7f2d5099072206e66f52b1","bytes":2156,"downloaded_at":"2026-04-28T17:42:52.485647+00:00"},{"id":16,"kind":"extraction","local_path":"/data/runs/01KQAJZE0AWC7D2R78QSJ8H7CT/extraction.json","drive_file_id":null,"sha256":null,"bytes":28170,"downloaded_at":"2026-04-28T17:44:22.572150+00:00"}],"has_final_patch":false,"final_patch_field_count":0,"_meta":{"collected_at":"2026-05-06T22:23:23.993050+00:00","iteration_count":0,"audit_log_count":15,"field_values_count":59,"artifacts_count":4,"has_final_patch":false}}